The SED-CXP2-Z is a twin-screw ultrasonic vial washing machine designed for cleaning glass vials on pharmaceutical and health-product filling lines. It uses a screw-conveyor structure where vials are inverted 180 degrees

GMP
Lieferzeit
Auf Anfrage
Durchsatz
2000 Flaschen/h

Funktionsweise

Vials are fed from a supply disk through a magnetic-clutch star wheel into the screw track. The magnetic clutch auto-stops the star wheel when a jam occurs and restarts when resistance clears. The screw track is lined with PTFE sleeves for smooth, scratch-free vial conveyance. Vials are inverted 180 degrees mouth-down and pass through the ultrasonic rough-wash zone -- tower-stack ultrasonic transducers (D28-2000, Shenzhen Kemeida) cause cavitation that strips particulate from vial walls. Bottles then proceed through recirculated water and purified water rinse stations, followed by purified compressed air drying. After rinsing, vials are flipped 180 degrees mouth-up and discharged to the outlet hopper. The heated wash tank maintains constant-temperature warm rinse water to improve cleaning effectiveness. Recirculation filtration uses a Nanfang stainless-steel pump (32-25-160).

Prozessbeschreibung
1Vials are fed from a supply disk through a magnetic-clutch star wheel into the screw track.
2The magnetic clutch auto-stops the star wheel when a jam occurs and restarts when resistance clears.
3The screw track is lined with PTFE sleeves for smooth, scratch-free vial conveyance.
4Vials are inverted 180 degrees mouth-down and pass through the ultrasonic rough-wash zone -- tower-stack ultrasonic transducers (D28-2000, Shenzhen Kemeida) cause cavitation that strips particulate from vial walls.
5Bottles then proceed through recirculated water and purified water rinse stations, followed by purified compressed air drying.
6After rinsing, vials are flipped 180 degrees mouth-up and discharged to the outlet hopper.
7The heated wash tank maintains constant-temperature warm rinse water to improve cleaning effectiveness.
8Recirculation filtration uses a Nanfang stainless-steel pump (32-25-160).

Technische Daten

Technische Daten für Variante: SED-CXP2-Z

Technische Daten

Modell
SED-CXP2-Z
Durchsatz
2000 Flaschen/h
Spannung
380V/50Hz 3-phase
Versorgung
Power: 380V 50Hz 3-phase 4-wire / 4 kW. Purified water: 0.8 m3/h at 0.2-0.25 MPa. WFI (injection water): 0.8 m3/h at 0.2-0.25 MPa. Purified compressed air: 36 m3/h at 0.2-0.25 MPa. Ultrasonic: 2 kW.
Konformitätsangaben
Designed to GMP requirements for pharmaceutical and health-product production. Structure simple and reliable; cleaning quality meets GMP vial washing standards.
Leistung
4 kW

Abmessungen

Länge
2500 mm
Breite
1200 mm
Höhe
1500 mm

Werkstoffe

Kontaktwerkstoffe
304 stainless steel body and inner liners (per source specification for SED-CXP2-Z).
Gehäusewerkstoffe
Brushed stainless steel outer cladding; 304 stainless steel inner liners.

Wesentliche Merkmale

Twin-screw (2-group) conveyor for 2000 vials/hour production capacity
Magnetic-clutch star wheel auto-stops on jam, auto-restarts when clear
PTFE-sleeved screw track -- smooth vial conveyance, no breakage
Tower-stack ultrasonic transducer (D28-2000) -- strong cavitation effect
Heated wash tank -- constant-temperature warm rinse improves cleaning
180-degree vial inversion (mouth-down) for effective contaminant drainage
Recirculated water, purified water, and compressed air filtration systems included
Breakage rate <=1% by design (magnetic slipping star wheel + PTFE track)
Siemens/Mitsubishi PLC + HMI for stable, reliable control
ABB 380V 0.75 kW motor; Delta/Schneider VFD
304 SS body inner liners; brushed SS outer cladding
Meets GMP requirements
Twin-screw configuration doubles throughput for high-volume vial lines
Heated wash tank ensures consistent cleaning quality across temperature variations
Breakage rate <=1% -- low product loss on fragile glass vials
Siemens/Mitsubishi PLC for validated process control
GMP-compliant for pharmaceutical injectable and health-product production

Anwendungen

Glass vial washing for injectable pharmaceutical production lines
Glass vial washing for health-product filling lines
High-throughput vial cleaning requiring twin-screw configuration

Branchen

Pharmaceutical injectables
Health products / nutraceuticals

Komponentenhersteller

Siemens / Mitsubishi (PLC + HMI) -- Germany / Japan
Nanfang Pump (washing pump 32-25-160, full SS) -- China
Shenzhen Kemeida (ultrasonic generator D28-2000) -- Shenzhen
Sipai HL-2S (level controller) -- Shanghai
Jingyan Motor (bottle-feed motor 180V 1:150) -- China
WPA60 reducer -- Hangzhou
ABB (main motor 380V 0.75 kW) -- Sweden
Schneider (VFD VFD015S21D) -- France
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

GMP

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen