SED-4-2400BRG-Q semi-automatic IV soft-bag filling and sealing machine. 4 filling heads. Worker manually loads empty bags onto the fixture, then a foot pedal triggers automatic filling, stoppering, and discharge. Two par

CEGMP-ready (with E+H mass meter)FDA-ready (with E+H mass meter)
Prazo de entrega
Consultar
Capacidade de produção
1200–2000 bags/hour

Como funciona

Worker loads empty soft IV bags onto the work-position fixture and presses the foot pedal. The machine clamps the bag mouth onto the filling head; a turbine flow meter (or optional E+H Coriolis mass flow meter for GMP/FDA-grade) and pneumatic diaphragm valve dose drug solution at 3–6 bar (0.3–0.5 MPa fill pressure) and ≤80°C, ±1% accuracy, with no-bag = no-fill interlock. After fill, the vibration bowl orients sealing-stoppers, vacuum mechanical hand picks each stopper and presses it into the bag port; no-bag = no-stopper, missing-cap alarm. Pneumatic gripper opens, bag drops onto exit conveyor or collection box. CIP runs by valve-open timing on touchscreen; SIP runs by sensing sterilization temperature and exposure time (steam supplied externally).

Processo de funcionamento
1Worker loads empty soft IV bags onto the work-position fixture and presses the foot pedal.
2The machine clamps the bag mouth onto the filling head; a turbine flow meter (or optional E+H Coriolis mass flow meter for GMP/FDA-grade) and pneumatic diaphragm valve dose drug solution at 3–6 bar (0.3–0.5 MPa fill pressure) and ≤80°C, ±1% accuracy, with no-bag = no-fill interlock.
3After fill, the vibration bowl orients sealing-stoppers, vacuum mechanical hand picks each stopper and presses it into the bag port; no-bag = no-stopper, missing-cap alarm.
4Pneumatic gripper opens, bag drops onto exit conveyor or collection box.
5CIP runs by valve-open timing on touchscreen; SIP runs by sensing sterilization temperature and exposure time (steam supplied externally).

Especificações técnicas

Especificações da variante: SED-4-2400BRG-Q

Especificações

Modelo
SED-4-2400BRG-Q
Capacidade de produção
1200–2000 bags/hour
Tensão
220V
Utilidades
220V power supply (max 5 kW); dry oil-free compressed air 0.65–0.8 MPa, 800 L/min; customer-supplied CIP wash water and overheated steam for SIP; fill liquid supplied by customer via standard tri-clamp connection
Potência
5 kW
Pressão de ar
0.65-0.8 MPa, 800 L/min (clean dry oil-free)

Dimensões

Comprimento
1200 mm
Largura
1000 mm
Altura
1700 mm
Área de instalação
1200 × 1000 mm base footprint, 1700 mm height

Materiais

Materiais de contato
SS316 stainless steel (drug-contact piping, filling heads); medical silicone rubber tubing; rated for 121°C terminal sterilization
Materiais do corpo
SS304 stainless steel (frame, structural parts, control cabinet); SS304 + high-clarity polycarbonate (safety doors and windows); SS304 IP54 control cabinet

Características principais

Semi-automatic — operator places bag, machine fills + stoppers + discharges
4 filling heads, 2 parallel work-zones (independent)
Compatible bag sizes 100–500 ml (line spec) / 100–1000 ml product line range
Throughput 1200–2000 bags/hour @100 ml (operator-, pressure- and air-dependent)
Standard sanitary turbine flow meter; optional E+H Coriolis mass flow meter (GMP/FDA grade)
Filling: ±1% accuracy, fill pressure 0.3–0.5 MPa, fill temp ≤80°C
On-board CIP/SIP plumbing and program (water + steam supplied by customer)
Pipework rated 125°C; wetted parts withstand 121°C terminal sterilization
No-bag = no fill / no stopper, missing-cap alarm
High-clarity polycarbonate safety doors and observation windows
Touchscreen with auto/manual modes, full alarms
IP54 SS304 control cabinet integrated into machine
CE certified — direct medical-product applicability
GMP/FDA upgrade path via E+H mass flow meter (4 sets) — protects against turbine-meter EMI errors
Compact 1.2×1.0×1.7 m footprint at 1200–2000 bags/hour
Built-in CIP/SIP avoids separate cleaning skid
Best-in-class component selection: Siemens PLC,SMC/Airtac pneumatics,Schneider electrical,Keyence sensors,Xinlai sanitary diaphragm valves,medical silicone tubing

Aplicações

100–500 ml IV soft-bag filling and stoppering
Pharmaceutical IV bag manufacturing (medical-grade liquids)

Setores

Pharmaceutical (sterile IV / parenteral solutions)

Marcas dos componentes

PLC
Siemens
Pneumatic cylinders + valves
SMC / Airtac
Sensors
SMC / Airtac / Keyence
Circuit breakers + low-voltage
Schneider
Sanitary diaphragm valves
Xinlai
Photo-fiber sensor
Keyence
Optional GMP/FDA mass flow meter
Endress+Hauser (E+H)
SED
Fale com SED Sales Team
Especialistas em equipamentos · contato pelo WhatsApp
Consulte o horário e a disponibilidade da equipe

Conformidade

CE
GMP-ready (with E+H mass meter)
FDA-ready (with E+H mass meter)

Documentação

Ficha técnica (PDF)
Visão geral do equipamento, especificações e dimensões · Documento original (inglês)
Solicitar à equipe de vendas
Manual do operador
Instalação, operação e diagnóstico · Documento original (inglês)
Solicitar à equipe de vendas
Folha comparativa (Padrão e Econômica)
Comparação das configurações · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos IQ / OQ / PQ
Documentação de validação para conformidade GMP · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos FAT / SAT
Testes de aceitação na fábrica e no local · Documento original (inglês)
Solicitar à equipe de vendas
Desenhos CAD (STEP / IGES / DWG)
Desenhos de engenharia para a instalação · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de calibração
Nível sonoro, resistência de terra, rigidez dielétrica e rugosidade · Documento original (inglês)
Solicitar à equipe de vendas
DQ (qualificação do projeto)
Protocolo completo de qualificação do projeto · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de materiais
Composição do aço inoxidável 316L · Documento original (inglês)
Solicitar à equipe de vendas
SED
WhatsApp · Vendas SED
Contato comercial · WhatsApp
→