SED-30JS-H Empty Capsule Feeder conveys empty capsules from a floor-level container up to the hopper of a capsule filling machine via stainless-steel piping and a rotating air (whirling) pump. Capacity 200,000–300,000 ca

Suitable for GMP-relevant pharmaceutical environments (must be installed in dry, non-flammable area)
Escolher variante (2)
Prazo de entrega
Consultar
Capacidade de produção
200000–300000 /

Como funciona

Operator presses the work start button; AC contactor KM engages and the whirling (rotary vane) air pump starts. The pump generates ~8 kPa pressure / 65 m³/h airflow that draws empty capsules from the floor-level container through a stainless-steel pipe up to the destination hopper on the capsule filling machine. A capsule level sensor at the top of the destination hopper detects when capsules reach the preset height; contactor KM opens and the air pump stops. As production consumes capsules and the level drops below the sensor, timing relay KT triggers a short delay then restarts the pump. The cycle repeats automatically until the source container is empty or operator stops the feeder. Note: timing relay delay should be adjusted to match production speed.

Processo de funcionamento
1Operator presses the work start button; AC contactor KM engages and the whirling (rotary vane) air pump starts.
2The pump generates ~8 kPa pressure / 65 m³/h airflow that draws empty capsules from the floor-level container through a stainless-steel pipe up to the destination hopper on the capsule filling machine.
3A capsule level sensor at the top of the destination hopper detects when capsules reach the preset height; contactor KM opens and the air pump stops.
4As production consumes capsules and the level drops below the sensor, timing relay KT triggers a short delay then restarts the pump.
5The cycle repeats automatically until the source container is empty or operator stops the feeder.
6Note: timing relay delay should be adjusted to match production speed.

Especificações técnicas

Especificações da variante: SED-30JS-H 200

Especificações

Modelo
SED-30JS-H
Capacidade de produção
200000–300000 /
Tensão
380V 50Hz 3-Phase
Utilidades
AC 380V/50Hz three-phase electric supply (0.55 kW); no external compressed air; dry, non-flammable installation area.
Detalhes de conformidade
Designed for GMP-relevant capsule production environments; must be installed in a dry location away from flammable/explosive atmospheres.
Potência
0.55 kW
Pressão de ar
Internal pump output ~8 kPa @ 65 m³/h (no external compressed air required)

Dimensões

Comprimento
850 mm
Largura
430 mm
Altura
2200 mm
Peso
63 kg
Área de instalação
850 mm (L) x 430 mm (W) base x 2200 mm (H, adjustable); place near filler hopper inlet with capsule source container at ground level.

Materiais

Materiais de contato
Stainless steel conveying pipe
Materiais do corpo
Painted steel base and motor enclosure; stainless steel pipework

Elétrica

Fase
trifásica

Operação

Reference Transport Distance
5 m (horizontal + vertical) m

Características principais

Pneumatic conveying — gentle on capsules, no mechanical agitation
Capacity 200,000–300,000 capsules/h over 5 m total run (horizontal + vertical); doubling distance halves capacity
Automatic start/stop on hopper level sensor
Adjustable timing relay delay matches restart cadence to production speed
Whirling rotary-vane air pump — 8 kPa, 65 m³/h; quiet and reliable
Stainless steel conveying pipe
Adjustable height (default 2200 mm) to match customer hopper height
Mobile — 63 kg lightweight design
380V three-phase, 0.55 kW
Continuous-duty operation
Air intake hole must be unobstructed; blocked inlet reverses motor direction
Eliminates manual capsule loading — operator can attend other tasks
Sensor-based start/stop prevents hopper overflow and idle running
Pneumatic gentleness avoids capsule shell damage
Pairs natively with SED-BJ-III, SED-BJ-III-H, and SED-1200J-H capsule filling machines
Mobile lightweight design — one feeder can serve multiple fillers in shift rotation
Stainless steel piping suits cleanroom and GMP environments
Adjustable height accommodates different filler hopper heights

Aplicações

Conveying empty hard gelatin capsules to capsule filler hoppers
Conveying HPMC (vegetable) capsules to fillers
Continuous capsule supply for SED-BJ-III, SED-BJ-III-H, SED-1200J-H production lines
Replacing manual capsule loading in SME pharma plants

Setores

Fabricação farmacêutica
Suplementos e nutracêuticos
Medicina veterinária
Envazadores de cápsulas por contrato

Marcas dos componentes

AC contactor KM
Timing relay KT
Whirling rotary-vane air pump (8 kPa, 65 m³/h)
SED
Fale com SED Sales Team
Especialistas em equipamentos · contato pelo WhatsApp
Consulte o horário e a disponibilidade da equipe

Conformidade

Suitable for GMP-relevant pharmaceutical environments (must be installed in dry, non-flammable area)

Limpeza e manutenção

Before each shift, verify the air intake hole is clear (if blocked, motor rotation direction may be reversed and must be adjusted). Insert and fix the stainless steel pipe firmly into the air hole. Wipe down the conveying pipe between SKU changes. Ensure the level sensor is clean. Adjust the timing relay delay to match production speed for optimal restart cadence.

Documentação

Ficha técnica (PDF)
Visão geral do equipamento, especificações e dimensões · Documento original (inglês)
Solicitar à equipe de vendas
Manual do operador
Instalação, operação e diagnóstico · Documento original (inglês)
Solicitar à equipe de vendas
Folha comparativa (Padrão e Econômica)
Comparação das configurações · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos IQ / OQ / PQ
Documentação de validação para conformidade GMP · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos FAT / SAT
Testes de aceitação na fábrica e no local · Documento original (inglês)
Solicitar à equipe de vendas
Desenhos CAD (STEP / IGES / DWG)
Desenhos de engenharia para a instalação · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de calibração
Nível sonoro, resistência de terra, rigidez dielétrica e rugosidade · Documento original (inglês)
Solicitar à equipe de vendas
DQ (qualificação do projeto)
Protocolo completo de qualificação do projeto · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de materiais
Composição do aço inoxidável 316L · Documento original (inglês)
Solicitar à equipe de vendas
SED
WhatsApp · Vendas SED
Contato comercial · WhatsApp
→