Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Alimentador de cápsulas / Empty Capsule Feeder (Auxiliary Equipment for Capsule Filling Machine)
SED-30JS-H
Consultar
SED-30JS-H Empty Capsule Feeder
SED · SED-30JS-H · 16 unidades vendidas

SED-30JS-H — Empty Capsule Feeder

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-30JS-H Empty Capsule Feeder conveys empty capsules from a floor-level container up to the hopper of a capsule filling machine via stainless-steel piping and a rotating air (whirling) pump. Capacity 200,000–300,000 ca

Suitable for GMP-relevant pharmaceutical environments (must be installed in dry, non-flammable area)
Elegir variante (2)
Plazo de entrega
Consultar
Capacidad de producción
200000–300000 /

Funcionamiento

Operator presses the work start button; AC contactor KM engages and the whirling (rotary vane) air pump starts. The pump generates ~8 kPa pressure / 65 m³/h airflow that draws empty capsules from the floor-level container through a stainless-steel pipe up to the destination hopper on the capsule filling machine. A capsule level sensor at the top of the destination hopper detects when capsules reach the preset height; contactor KM opens and the air pump stops. As production consumes capsules and the level drops below the sensor, timing relay KT triggers a short delay then restarts the pump. The cycle repeats automatically until the source container is empty or operator stops the feeder. Note: timing relay delay should be adjusted to match production speed.

Proceso de funcionamiento
1Operator presses the work start button; AC contactor KM engages and the whirling (rotary vane) air pump starts.
2The pump generates ~8 kPa pressure / 65 m³/h airflow that draws empty capsules from the floor-level container through a stainless-steel pipe up to the destination hopper on the capsule filling machine.
3A capsule level sensor at the top of the destination hopper detects when capsules reach the preset height; contactor KM opens and the air pump stops.
4As production consumes capsules and the level drops below the sensor, timing relay KT triggers a short delay then restarts the pump.
5The cycle repeats automatically until the source container is empty or operator stops the feeder.
6Note: timing relay delay should be adjusted to match production speed.

Especificaciones técnicas

Especificaciones de la variante: SED-30JS-H 200

Especificaciones

Modelo
SED-30JS-H
Capacidad de producción
200000–300000 /
Tensión
380V 50Hz 3-Phase
Suministros
AC 380V/50Hz three-phase electric supply (0.55 kW); no external compressed air; dry, non-flammable installation area.
Detalles de conformidad
Designed for GMP-relevant capsule production environments; must be installed in a dry location away from flammable/explosive atmospheres.
Potencia
0.55 kW
Presión de aire
Internal pump output ~8 kPa @ 65 m³/h (no external compressed air required)

Dimensiones

Longitud
850 mm
Anchura
430 mm
Altura
2200 mm
Peso
63 kg
Superficie de instalación
850 mm (L) x 430 mm (W) base x 2200 mm (H, adjustable); place near filler hopper inlet with capsule source container at ground level.

Materiales

Materiales en contacto
Stainless steel conveying pipe
Materiales del cuerpo
Painted steel base and motor enclosure; stainless steel pipework

Electricidad

Fase
trifásica

Funcionamiento

Reference Transport Distance
5 m (horizontal + vertical) m

Características principales

Pneumatic conveying — gentle on capsules, no mechanical agitation
Capacity 200,000–300,000 capsules/h over 5 m total run (horizontal + vertical); doubling distance halves capacity
Automatic start/stop on hopper level sensor
Adjustable timing relay delay matches restart cadence to production speed
Whirling rotary-vane air pump — 8 kPa, 65 m³/h; quiet and reliable
Stainless steel conveying pipe
Adjustable height (default 2200 mm) to match customer hopper height
Mobile — 63 kg lightweight design
380V three-phase, 0.55 kW
Continuous-duty operation
Air intake hole must be unobstructed; blocked inlet reverses motor direction
Eliminates manual capsule loading — operator can attend other tasks
Sensor-based start/stop prevents hopper overflow and idle running
Pneumatic gentleness avoids capsule shell damage
Pairs natively with SED-BJ-III, SED-BJ-III-H, and SED-1200J-H capsule filling machines
Mobile lightweight design — one feeder can serve multiple fillers in shift rotation
Stainless steel piping suits cleanroom and GMP environments
Adjustable height accommodates different filler hopper heights

Aplicaciones

Conveying empty hard gelatin capsules to capsule filler hoppers
Conveying HPMC (vegetable) capsules to fillers
Continuous capsule supply for SED-BJ-III, SED-BJ-III-H, SED-1200J-H production lines
Replacing manual capsule loading in SME pharma plants

Sectores

Fabricación farmacéutica
Suplementos y nutracéuticos
Medicina veterinaria
Llenadores de cápsulas por contrato

Marcas de componentes

AC contactor KM
Timing relay KT
Whirling rotary-vane air pump (8 kPa, 65 m³/h)
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

Suitable for GMP-relevant pharmaceutical environments (must be installed in dry, non-flammable area)

Limpieza y mantenimiento

Before each shift, verify the air intake hole is clear (if blocked, motor rotation direction may be reversed and must be adjusted). Insert and fix the stainless steel pipe firmly into the air hole. Wipe down the conveying pipe between SKU changes. Ensure the level sensor is clean. Adjust the timing relay delay to match production speed for optimal restart cadence.

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→