Showroom em Ontario, Califórnia · Consulte o suporte para seu destino
Início / Equipamentos / Cromatógrafo líquido / Agilent 1260 Infinity II HPLC System (with Fluorescence and ELSD Detectors)
SED-1260YXSPY-R
Consultar
SED-1260YXSPY-R
SED · SED-1260YXSPY-R · Em destaque

SED-1260YXSPY-R — Agilent 1260 Infinity II HPLC System

A descrição completa deste modelo ainda está sendo traduzida. Consulte os detalhes em inglês ou solicite informações à nossa equipe. English

SED-1260YXSPY-R is a configured Agilent 1260 Infinity II HPLC system bundle for laboratory R&D, specified with quaternary pump, vialsampler, multicolumn thermostat, and three detectors (variable-wavelength, fluorescence

Prazo de entrega
Consultar
Capacidade de produção
Fale conosco

Como funciona

Mobile phases are blended by an Agilent G7111B 1260 Infinity II quaternary pump capable of 600 bar pressure with active inlet valve and active seal-wash. The G7129A vialsampler injects samples (132-position tray, 6×11 standard drawer, 2 mL vials) with optional InfinityLab Sample Thermostat cooling. The G7116A multicolumn thermostat conditions the column. Eluent passes successively through three detectors: G7114A VWD, G7121B Fluorescence Detector Spectra and G4260B Evaporative Light Scattering Detector — providing UV, fluorescence and universal mass-flow detection. OpenLab CDS workstation software (M8413AA) controls instrumentation and processes chromatograms.

Processo de funcionamento
1Mobile phases are blended by an Agilent G7111B 1260 Infinity II quaternary pump capable of 600 bar pressure with active inlet valve and active seal-wash.
2The G7129A vialsampler injects samples (132-position tray, 6×11 standard drawer, 2 mL vials) with optional InfinityLab Sample Thermostat cooling.
3The G7116A multicolumn thermostat conditions the column.
4Eluent passes successively through three detectors: G7114A VWD, G7121B Fluorescence Detector Spectra and G4260B Evaporative Light Scattering Detector — providing UV, fluorescence and universal mass-flow detection.
5OpenLab CDS workstation software (M8413AA) controls instrumentation and processes chromatograms.

Especificações técnicas

Especificações da variante: SED-1260YXSPY-R

Especificações

Modelo
SED-1260YXSPY-R
Utilidades
Mains electrical supply, compressed nitrogen for the ELSD nebulizer, vacuum waste line, lab-grade solvents and Type I water (specific values not stated in source).
Detalhes de conformidade
OpenLab CDS supports compliance workflows; specific certifications not stated in source.

Dimensões

Área de instalação
Standard Agilent 1260 Infinity II benchtop stack (specific dimensions not provided in source).

Materiais

Materiais de contato
Agilent-standard wetted materials (stainless steel and PEEK fluid path; silica-based reversed-phase columns)
Materiais do corpo
Agilent-standard chassis (specifications not provided in source)

Características principais

Quaternary pump (G7111B), 600 bar, with HPLC System Tool Kit, Max Uptime Kit, Active Seal Wash and Active Inlet Valve
132-position vialsampler (G7129A) with 2 mL vial drawer (6×11) and InfinityLab Sample Thermostat
High-capacity multicolumn thermostat (G7116A)
Variable Wavelength Detector (G7114A) with standard flow cell
Fluorescence Detector Spectra (G7121B)
Evaporative Light Scattering Detector (G4260B)
OpenLab CDS Workstation Software (M8413AA)
Includes Poroshell 120 EC-C18 4.6×150 mm 4 μm
Includes Eclipse Plus C18 4.6×250 mm 5 μm
Includes ODS Analytical HPLC Column 4.6×250 mm
Triple-detector configuration (UV + fluorescence + ELSD) supports the widest range of analyte chemistries on a single platform
Genuine Agilent 1260 Infinity II hardware with vendor support
OpenLab CDS provides 21 CFR Part 11-ready data handling for regulated labs
Bundled column set covers RP-HPLC method scouting from day one

Aplicações

Quantitative HPLC analysis of pharmaceutical APIs and impurities
Method development with multi-detector confirmation
Analysis of compounds with no UV chromophore (via ELSD)
Trace-level fluorescent analyte quantification
Stability and content-uniformity testing

Setores

Pharmaceutical QC and R&D
Analytical / contract testing laboratories
Academic research labs
Food, environmental and chemical analysis
SED
Fale com SED Sales Team
Especialistas em equipamentos · contato pelo WhatsApp
Consulte o horário e a disponibilidade da equipe

Limpeza e manutenção

Source does not specify cleaning procedure beyond Active Seal Wash option for the pump.

Documentação

Ficha técnica (PDF)
Visão geral do equipamento, especificações e dimensões · Documento original (inglês)
Solicitar à equipe de vendas
Manual do operador
Instalação, operação e diagnóstico · Documento original (inglês)
Solicitar à equipe de vendas
Folha comparativa (Padrão e Econômica)
Comparação das configurações · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos IQ / OQ / PQ
Documentação de validação para conformidade GMP · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos FAT / SAT
Testes de aceitação na fábrica e no local · Documento original (inglês)
Solicitar à equipe de vendas
Desenhos CAD (STEP / IGES / DWG)
Desenhos de engenharia para a instalação · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de calibração
Nível sonoro, resistência de terra, rigidez dielétrica e rugosidade · Documento original (inglês)
Solicitar à equipe de vendas
DQ (qualificação do projeto)
Protocolo completo de qualificação do projeto · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de materiais
Composição do aço inoxidável 316L · Documento original (inglês)
Solicitar à equipe de vendas
SED
WhatsApp · Vendas SED
Contato comercial · WhatsApp
→