Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Cromatógrafo de líquidos / Agilent 1260 Infinity II HPLC System (with Fluorescence and ELSD Detectors)
SED-1260YXSPY-R
Consultar
SED-1260YXSPY-R
SED · SED-1260YXSPY-R · Destacado

SED-1260YXSPY-R — Agilent 1260 Infinity II HPLC System

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-1260YXSPY-R is a configured Agilent 1260 Infinity II HPLC system bundle for laboratory R&D, specified with quaternary pump, vialsampler, multicolumn thermostat, and three detectors (variable-wavelength, fluorescence

Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Mobile phases are blended by an Agilent G7111B 1260 Infinity II quaternary pump capable of 600 bar pressure with active inlet valve and active seal-wash. The G7129A vialsampler injects samples (132-position tray, 6×11 standard drawer, 2 mL vials) with optional InfinityLab Sample Thermostat cooling. The G7116A multicolumn thermostat conditions the column. Eluent passes successively through three detectors: G7114A VWD, G7121B Fluorescence Detector Spectra and G4260B Evaporative Light Scattering Detector — providing UV, fluorescence and universal mass-flow detection. OpenLab CDS workstation software (M8413AA) controls instrumentation and processes chromatograms.

Proceso de funcionamiento
1Mobile phases are blended by an Agilent G7111B 1260 Infinity II quaternary pump capable of 600 bar pressure with active inlet valve and active seal-wash.
2The G7129A vialsampler injects samples (132-position tray, 6×11 standard drawer, 2 mL vials) with optional InfinityLab Sample Thermostat cooling.
3The G7116A multicolumn thermostat conditions the column.
4Eluent passes successively through three detectors: G7114A VWD, G7121B Fluorescence Detector Spectra and G4260B Evaporative Light Scattering Detector — providing UV, fluorescence and universal mass-flow detection.
5OpenLab CDS workstation software (M8413AA) controls instrumentation and processes chromatograms.

Especificaciones técnicas

Especificaciones de la variante: SED-1260YXSPY-R

Especificaciones

Modelo
SED-1260YXSPY-R
Suministros
Mains electrical supply, compressed nitrogen for the ELSD nebulizer, vacuum waste line, lab-grade solvents and Type I water (specific values not stated in source).
Detalles de conformidad
OpenLab CDS supports compliance workflows; specific certifications not stated in source.

Dimensiones

Superficie de instalación
Standard Agilent 1260 Infinity II benchtop stack (specific dimensions not provided in source).

Materiales

Materiales en contacto
Agilent-standard wetted materials (stainless steel and PEEK fluid path; silica-based reversed-phase columns)
Materiales del cuerpo
Agilent-standard chassis (specifications not provided in source)

Características principales

Quaternary pump (G7111B), 600 bar, with HPLC System Tool Kit, Max Uptime Kit, Active Seal Wash and Active Inlet Valve
132-position vialsampler (G7129A) with 2 mL vial drawer (6×11) and InfinityLab Sample Thermostat
High-capacity multicolumn thermostat (G7116A)
Variable Wavelength Detector (G7114A) with standard flow cell
Fluorescence Detector Spectra (G7121B)
Evaporative Light Scattering Detector (G4260B)
OpenLab CDS Workstation Software (M8413AA)
Includes Poroshell 120 EC-C18 4.6×150 mm 4 μm
Includes Eclipse Plus C18 4.6×250 mm 5 μm
Includes ODS Analytical HPLC Column 4.6×250 mm
Triple-detector configuration (UV + fluorescence + ELSD) supports the widest range of analyte chemistries on a single platform
Genuine Agilent 1260 Infinity II hardware with vendor support
OpenLab CDS provides 21 CFR Part 11-ready data handling for regulated labs
Bundled column set covers RP-HPLC method scouting from day one

Aplicaciones

Quantitative HPLC analysis of pharmaceutical APIs and impurities
Method development with multi-detector confirmation
Analysis of compounds with no UV chromophore (via ELSD)
Trace-level fluorescent analyte quantification
Stability and content-uniformity testing

Sectores

Pharmaceutical QC and R&D
Analytical / contract testing laboratories
Academic research labs
Food, environmental and chemical analysis
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Limpieza y mantenimiento

Source does not specify cleaning procedure beyond Active Seal Wash option for the pump.

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→