SED-1260YXSPY-R is a configured Agilent 1260 Infinity II HPLC system bundle for laboratory R&D, specified with quaternary pump, vialsampler, multicolumn thermostat, and three detectors (variable-wavelength, fluorescence

Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Mobile phases are blended by an Agilent G7111B 1260 Infinity II quaternary pump capable of 600 bar pressure with active inlet valve and active seal-wash. The G7129A vialsampler injects samples (132-position tray, 6×11 standard drawer, 2 mL vials) with optional InfinityLab Sample Thermostat cooling. The G7116A multicolumn thermostat conditions the column. Eluent passes successively through three detectors: G7114A VWD, G7121B Fluorescence Detector Spectra and G4260B Evaporative Light Scattering Detector — providing UV, fluorescence and universal mass-flow detection. OpenLab CDS workstation software (M8413AA) controls instrumentation and processes chromatograms.

Processus de fonctionnement
1Mobile phases are blended by an Agilent G7111B 1260 Infinity II quaternary pump capable of 600 bar pressure with active inlet valve and active seal-wash.
2The G7129A vialsampler injects samples (132-position tray, 6×11 standard drawer, 2 mL vials) with optional InfinityLab Sample Thermostat cooling.
3The G7116A multicolumn thermostat conditions the column.
4Eluent passes successively through three detectors: G7114A VWD, G7121B Fluorescence Detector Spectra and G4260B Evaporative Light Scattering Detector — providing UV, fluorescence and universal mass-flow detection.
5OpenLab CDS workstation software (M8413AA) controls instrumentation and processes chromatograms.

Caractéristiques techniques

Caractéristiques de la variante : SED-1260YXSPY-R

Caractéristiques

Modèle
SED-1260YXSPY-R
Fluides et énergie
Mains electrical supply, compressed nitrogen for the ELSD nebulizer, vacuum waste line, lab-grade solvents and Type I water (specific values not stated in source).
Détails de conformité
OpenLab CDS supports compliance workflows; specific certifications not stated in source.

Dimensions

Emprise au sol
Standard Agilent 1260 Infinity II benchtop stack (specific dimensions not provided in source).

Matériaux

Matériaux en contact
Agilent-standard wetted materials (stainless steel and PEEK fluid path; silica-based reversed-phase columns)
Matériaux du bâti
Agilent-standard chassis (specifications not provided in source)

Caractéristiques principales

Quaternary pump (G7111B), 600 bar, with HPLC System Tool Kit, Max Uptime Kit, Active Seal Wash and Active Inlet Valve
132-position vialsampler (G7129A) with 2 mL vial drawer (6×11) and InfinityLab Sample Thermostat
High-capacity multicolumn thermostat (G7116A)
Variable Wavelength Detector (G7114A) with standard flow cell
Fluorescence Detector Spectra (G7121B)
Evaporative Light Scattering Detector (G4260B)
OpenLab CDS Workstation Software (M8413AA)
Includes Poroshell 120 EC-C18 4.6×150 mm 4 μm
Includes Eclipse Plus C18 4.6×250 mm 5 μm
Includes ODS Analytical HPLC Column 4.6×250 mm
Triple-detector configuration (UV + fluorescence + ELSD) supports the widest range of analyte chemistries on a single platform
Genuine Agilent 1260 Infinity II hardware with vendor support
OpenLab CDS provides 21 CFR Part 11-ready data handling for regulated labs
Bundled column set covers RP-HPLC method scouting from day one

Applications

Quantitative HPLC analysis of pharmaceutical APIs and impurities
Method development with multi-detector confirmation
Analysis of compounds with no UV chromophore (via ELSD)
Trace-level fluorescent analyte quantification
Stability and content-uniformity testing

Secteurs

Pharmaceutical QC and R&D
Analytical / contract testing laboratories
Academic research labs
Food, environmental and chemical analysis
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Nettoyage et entretien

Source does not specify cleaning procedure beyond Active Seal Wash option for the pump.

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→