Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
Startseite / Maschinen / Flüssigchromatograph / Agilent 1260 Infinity II HPLC System (with Fluorescence and ELSD Detectors)
SED-1260YXSPY-R
Auf Anfrage
SED-1260YXSPY-R
SED · SED-1260YXSPY-R · Hervorgehoben

SED-1260YXSPY-R — Agilent 1260 Infinity II HPLC System

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-1260YXSPY-R is a configured Agilent 1260 Infinity II HPLC system bundle for laboratory R&D, specified with quaternary pump, vialsampler, multicolumn thermostat, and three detectors (variable-wavelength, fluorescence

Lieferzeit
Auf Anfrage
Durchsatz
Kontaktieren Sie uns

Funktionsweise

Mobile phases are blended by an Agilent G7111B 1260 Infinity II quaternary pump capable of 600 bar pressure with active inlet valve and active seal-wash. The G7129A vialsampler injects samples (132-position tray, 6×11 standard drawer, 2 mL vials) with optional InfinityLab Sample Thermostat cooling. The G7116A multicolumn thermostat conditions the column. Eluent passes successively through three detectors: G7114A VWD, G7121B Fluorescence Detector Spectra and G4260B Evaporative Light Scattering Detector — providing UV, fluorescence and universal mass-flow detection. OpenLab CDS workstation software (M8413AA) controls instrumentation and processes chromatograms.

Prozessbeschreibung
1Mobile phases are blended by an Agilent G7111B 1260 Infinity II quaternary pump capable of 600 bar pressure with active inlet valve and active seal-wash.
2The G7129A vialsampler injects samples (132-position tray, 6×11 standard drawer, 2 mL vials) with optional InfinityLab Sample Thermostat cooling.
3The G7116A multicolumn thermostat conditions the column.
4Eluent passes successively through three detectors: G7114A VWD, G7121B Fluorescence Detector Spectra and G4260B Evaporative Light Scattering Detector — providing UV, fluorescence and universal mass-flow detection.
5OpenLab CDS workstation software (M8413AA) controls instrumentation and processes chromatograms.

Technische Daten

Technische Daten für Variante: SED-1260YXSPY-R

Technische Daten

Modell
SED-1260YXSPY-R
Versorgung
Mains electrical supply, compressed nitrogen for the ELSD nebulizer, vacuum waste line, lab-grade solvents and Type I water (specific values not stated in source).
Konformitätsangaben
OpenLab CDS supports compliance workflows; specific certifications not stated in source.

Abmessungen

Aufstellfläche
Standard Agilent 1260 Infinity II benchtop stack (specific dimensions not provided in source).

Werkstoffe

Kontaktwerkstoffe
Agilent-standard wetted materials (stainless steel and PEEK fluid path; silica-based reversed-phase columns)
Gehäusewerkstoffe
Agilent-standard chassis (specifications not provided in source)

Wesentliche Merkmale

Quaternary pump (G7111B), 600 bar, with HPLC System Tool Kit, Max Uptime Kit, Active Seal Wash and Active Inlet Valve
132-position vialsampler (G7129A) with 2 mL vial drawer (6×11) and InfinityLab Sample Thermostat
High-capacity multicolumn thermostat (G7116A)
Variable Wavelength Detector (G7114A) with standard flow cell
Fluorescence Detector Spectra (G7121B)
Evaporative Light Scattering Detector (G4260B)
OpenLab CDS Workstation Software (M8413AA)
Includes Poroshell 120 EC-C18 4.6×150 mm 4 μm
Includes Eclipse Plus C18 4.6×250 mm 5 μm
Includes ODS Analytical HPLC Column 4.6×250 mm
Triple-detector configuration (UV + fluorescence + ELSD) supports the widest range of analyte chemistries on a single platform
Genuine Agilent 1260 Infinity II hardware with vendor support
OpenLab CDS provides 21 CFR Part 11-ready data handling for regulated labs
Bundled column set covers RP-HPLC method scouting from day one

Anwendungen

Quantitative HPLC analysis of pharmaceutical APIs and impurities
Method development with multi-detector confirmation
Analysis of compounds with no UV chromophore (via ELSD)
Trace-level fluorescent analyte quantification
Stability and content-uniformity testing

Branchen

Pharmaceutical QC and R&D
Analytical / contract testing laboratories
Academic research labs
Food, environmental and chemical analysis
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Reinigung und Wartung

Source does not specify cleaning procedure beyond Active Seal Wash option for the pump.

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→