Accueil / Équipements / Autoclave à vide pulsé / Pulsating Vacuum Sterilizer (Autoclave) – SED-0.5MM-J
SED-0.5MM-J
Sur devis
SED-0.5MM-J
SED · SED-0.5MM-J · En vedette

SED-0.5MM-J

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-0.5MM-J Pulsating Vacuum Sterilizer (Pulsating Vacuum Autoclave) – a horizontal double-layer, airtight-sealed, double-leaf motorized-door sterilizer for pharmaceutical and hospital use. Inner chamber (SS316L, 6 mm) d

Designed and manufactured to GMP standard with standard GMP validation interfaceGB150-2011 (Steel Pressure Vessel) compliantX-ray flaw-detection inspection with quality certificates from labor authority
Choisir une variante (1)
Délai de livraison
Sur devis
Cadence
500 L/h

Fonctionnement

Pulsating-vacuum saturated-steam sterilization. The horizontal double-layer chamber (SS316L inner vessel, SS304 fully-enclosed jacket) uses pulsating vacuum exhaust to eliminate residual cold air, ensuring temperature uniformity throughout the load. Saturated steam at 0.4–0.6 MPa (working: 0.22 MPa / 134 °C) is then admitted; the steam's latent heat condenses on the sterilized items, raising them to sterilization temperature. After the sterilization hold time, vacuum drying combined with jacket heating dries the load. Process flow: Auto Preparation → Pulsating Vacuum → Heat-Up → Sterilization → Drying → End. All parameters are monitored and recorded in real time by Siemens PLC; sterilization reports (pressure, temperature, time, F0 value) are printed by the micro printer.

Processus de fonctionnement
1Pulsating-vacuum saturated-steam sterilization.
2The horizontal double-layer chamber (SS316L inner vessel, SS304 fully-enclosed jacket) uses pulsating vacuum exhaust to eliminate residual cold air, ensuring temperature uniformity throughout the load.
3Saturated steam at 0.4–0.6 MPa (working: 0.22 MPa / 134 °C) is then admitted; the steam's latent heat condenses on the sterilized items, raising them to sterilization temperature.
4After the sterilization hold time, vacuum drying combined with jacket heating dries the load.
5Process flow: Auto Preparation → Pulsating Vacuum → Heat-Up → Sterilization → Drying → End.
6All parameters are monitored and recorded in real time by Siemens PLC; sterilization reports (pressure, temperature, time, F0 value) are printed by the micro printer.

Caractéristiques techniques

Caractéristiques de la variante : SED-0 chamber 870 × 680 × 850 mm

Caractéristiques

Modèle
SED-0.5MM-J
Cadence
500 L/h
Tension
AC 380 V, 50 Hz, 3-phase 5-wire
Fluides et énergie
Electrical: AC 380 V, 50 Hz, 3-phase 5-wire, 2.5 kWh/cycle. Saturated steam 0.4–0.6 MPa, ~35 kg/cycle. Drinking water / pure water 0.1–0.3 MPa, ~200 kg/cycle. Compressed air 0.5–0.7 MPa for door sealing and pneumatic valves.
Détails de conformité
Strictly designed and manufactured to pharmaceutical GMP standard with a standard GMP validation interface (real-time output and archive of sterilization records including pressure, temperature, time, and F0 value). Pressure vessel complies with GB150-2011; X-ray flaw-detected with complete quality certificates. Door safety interlocks fully comply with pressure-vessel safety-interlock standards.
Puissance
2.5 kW
Pression d’air
Compressed air 0.5~0.7 MPa; saturated steam 0.4~0.6 MPa; water 0.1~0.3 MPa; ultimate vacuum -0.095 MPa

Dimensions

Longueur
1150 mm
Largeur
1400 mm
Hauteur
1920 mm
Poids
1200 kg
Emprise au sol
Overall 1 150 (L) × 1 400 (W) × 1 920 (H) mm; net weight 1 200 kg. Inner chamber 870 × 680 × 850 mm. Pass-through double-leaf design – install in wall between sterile and non-sterile rooms.

Matériaux

Matériaux en contact
SS316L inner chamber (6 mm) and door board (8 mm); SS304 door rack (sawtooth); SS304 sieve plate; SS304 sanitary-grade piping and weld fittings; medical silicone-rubber door gasket
Matériaux du bâti
SS316L inner chamber – SS304 fully-enclosed jacket – SS304 1.2 mm oil-mill drawn outer decorative cover – 50 mm aluminum-silicate insulation

Caractéristiques principales

Double-leaf motorized doors with airtight compressed-air-actuated medical silicone gasket
Door interlocks: operating area / sterile area separation; no steam admitted until sealed; no opening while chamber is pressurized
SS316L inner chamber (6 mm); SS304 door board (8 mm); SS304 sieve plate
50 mm aluminum-silicate insulating layer – minimizes heat radiation and conduction
SS304 1.2 mm oil-mill drawn outer decorative cover – durable and easy to clean
Siemens S7-200 PLC – 50 000-hour MTBF; full-process pressure and temperature auto-control
Taiwan TRE touch screen – bilingual, curve printing, electronic signature, administrator privileges
Beijing Weihuang micro printer (original EPSON chip) – sterilization report + temperature trend chart
ASCO USA / Burkert Germany angle-seat pneumatic valves – 4-million-cycle operating life
Shanghai Yulong water-ring vacuum pump – low noise, high vacuum
Jiangsu Santong air filter – filtration precision ≤ 0.22 μm (sterile filtration)
Taiwan Airtac solenoid valves – reliable, long service life
Switzerland HUBA pressure transmitter – high-precision, anti-interference
Iris PT100 temperature probe – Grade A accuracy, error ≤ 0.15 °C
Dual temperature channel monitoring and data storage in chamber
GMP validation interface with real-time sterilization record output and archive
Strictly GMP-compliant design with standard validation interface – supports regulatory audit
SS316L inner chamber + SS304 jacket – superior corrosion resistance for demanding sterilization cycles
Premium imported components (Siemens, ASCO, Burkert, HUBA) – validated reliability
Pass-through double-leaf door design – enables clean-room integration and batch traceability
Pulsating vacuum ensures complete cold-air removal – guaranteed temperature uniformity ≤ ±1 °C
Modular options: 36 kW clean-steam generator + 500 L/h water softener available as package
Full-cycle automation with electronic record archiving – reduces manual error and labor cost

Applications

Saturated-steam sterilization of clothing and dressings
Sterilization of metal medical/surgical instruments
Culture-medium sterilization
Glassware sterilization
Bowie & Dick / vacuum leak test
Pharmaceutical manufacturing sterilization cycles

Secteurs

Hospitals
Fabrication pharmaceutique
Health authorities and research institutes
Medical device sterilization

Marques des composants

SIEMENS Germany – S7-200 PLC
TRE Taiwan – touch screen
Beijing Weihuang (BRIGHTEK) – micro printer (original EPSON chip)
ASCO USA / Burkert Germany – angle-seat pneumatic valves
Shanghai Yulong – water-ring vacuum pump
Jiangsu Santong – air filter (≤ 0.22 μm)
Taiwan Airtac – solenoid valves
Zhongzhi CIS – steam trap
Beijing Brady – pressure gauge
Zhejiang Guangyi – safety valve
Switzerland HUBA – pressure transmitter
Iris – PT100 temperature probe (Grade A, ≤ 0.15 °C error)
JRPM – paperless recorder
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

Designed and manufactured to GMP standard with standard GMP validation interface
GB150-2011 (Steel Pressure Vessel) compliant
X-ray flaw-detection inspection with quality certificates from labor authority

Nettoyage et entretien

Sterilization chamber inner surface receives precision mechanical and chemical finishing for corrosion resistance and easy cleaning. Outer SS304 1.2 mm oil-mill drawn cover wipes clean. Sanitary-grade clamp-connection piping has no crevices – easy to inspect and clean. SS304 sieve plate is removable for cleaning.

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)