Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Detección de fugas / Sealing Tester / Leak Tester
SED-MCY-A
Consultar
SED-MCY-A Sealing Tester / Leak Tester
SED · SED-MCY-A · 9 unidades vendidas

SED-MCY-A — Sealing Tester / Leak Tester

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-MCY-A is a vacuum sealing tester (leak tester) designed and manufactured per GB/T 15171-94 — test method for sealing performance of flexible packaging — widely used for QC of food, pharmaceutical, daily-chemical and

Elegir variante (2)
Plazo de entrega
Consultar
Capacidad de producción
12–60 L/min extraction rate (vacuum-pump version)

Funcionamiento

Sample is placed inside the acrylic transparent vacuum tank with water around it (water level ~10 mm above the perforated press plate). The instrument evacuates the tank via either a compressed-air-driven Venturi vacuum generator (compressor version) or an external rotary-vane vacuum pump (vacuum-pump version). When the tank pressure reaches the set negative pressure ±accuracy band, the pump cycles off; if pressure rises above the band, the pump kicks back in. Sealed packaging in the water has higher internal pressure than the surrounding tank — leaks emit a stream of bubbles visible through the acrylic. After the user-set hold time elapses (1–9999 s), the instrument automatically opens the relief solenoid valve, returning tank pressure to atmospheric.

Proceso de funcionamiento
1Sample is placed inside the acrylic transparent vacuum tank with water around it (water level ~10 mm above the perforated press plate).
2The instrument evacuates the tank via either a compressed-air-driven Venturi vacuum generator (compressor version) or an external rotary-vane vacuum pump (vacuum-pump version).
3When the tank pressure reaches the set negative pressure ±accuracy band, the pump cycles off; if pressure rises above the band, the pump kicks back in.
4Sealed packaging in the water has higher internal pressure than the surrounding tank — leaks emit a stream of bubbles visible through the acrylic.
5After the user-set hold time elapses (1–9999 s), the instrument automatically opens the relief solenoid valve, returning tank pressure to atmospheric.

Especificaciones técnicas

Especificaciones de la variante: SED-MCY-A air-compressor version (Venturi generator

Especificaciones

Modelo
SED-MCY-A
Capacidad de producción
12–60 L/min extraction rate (vacuum-pump version)
Tensión
AC 220V 50/60Hz, 200 W
Suministros
AC 220V 50/60Hz, 200 W. Compressed air at 0.7 MPa for compressor version OR external rotary-vane vacuum pump (VALUE FY-1H-N) for vacuum-pump version. Reliable grounding.
Detalles de conformidad
Designed per GB/T 15171-94 for flexible packaging sealing test. Reliable grounding required. Cannot be used in high-humidity, strong-corrosive-gas, strong-vibration or high-EMI environments.
Potencia
0.2 kW
Presión de aire
Pressure source 0.7 MPa (7 kgf/cm2) for compressor variant; vacuum 0-90 kPa (compressor) or 0-95 kPa (vacuum-pump)

Dimensiones

Longitud
300 mm
Anchura
380 mm
Altura
200 mm
Peso
18 kg
Superficie de instalación
Controller 300 × 380 × 200 mm benchtop; vacuum tank Φ270 × 210 mm H standard, optional Φ360 × 585 mm or Φ460 × 330 mm. Reserve ≥1 m clearance. Ambient 10–40 °C; clean, dry, low-EMI environment.

Materiales

Materiales en contacto
Acrylic transparent vacuum tank; SMC pneumatic fittings; PU 6 mm and 8 mm air tubing

Funcionamiento

Operating Humidity
<=85% RH
Operating Temperature
5-35 degC °C
Vacuum Accuracy
class 0.5
Vacuum Hold Time
2.5h h
Vacuum Range
0 to -90 kPa kPa
Resolution
0.1 kPa kPa

Características físicas

Air Port Size
Ø6mm polyurethane tube mm
Chamber Size
Ø270mm x 210mm H (standard)

Características principales

Vacuum range 0–90 kPa (compressor) or 0–95 kPa (vacuum-pump variant)
Pressure-display accuracy ±0.5 kPa, resolution 0.1 kPa
Vacuum hold time 1–9999 seconds (~277 hours)
Maximum holding pressure −99.9 kPa
Settable accuracy / hysteresis band per test recipe
Extraction rate 12 L/min (compressor) or 60 L/min (vacuum pump)
Acrylic transparent vacuum tank for visual leak observation
Standard tank Φ270 × 210 mm H; optional Φ360 × 585 mm and Φ460 × 330 mm
LCD display + touch-button human-machine interface (Chinese/English)
Auto pressurise / hold / release cycle with intelligent control
Manual mode (Start / Stop / Blow Back) for diagnostic operation
Designed to GB/T 15171-94
Pressure calibration function with on-screen wizard (password 3052)
SMC pneumatic components (Japan) — reliable, low maintenance
Front-panel result-record button for pass/fail logging
Net weight 18 kg; controller 300 × 380 × 200 mm; AC 220V / 200 W
Auto-detect zero point and altitude-compensation calibration
Beep indicator for last 5 seconds of countdown
Two vacuum-source options — reuse existing air compressor or attach VALUE rotary-vane pump
Acrylic transparent tank lets QC visually confirm leaks — simple training
Designed to national standard GB/T 15171-94 — export-ready
Wide tank size options for ampoules, blister, pouches, large bottles
SMC pneumatics + electronic pressure sensor — lab-grade accuracy
Lifetime maintenance support after 12-month warranty
Compact bench size suits any QC lab

Aplicaciones

Sealing test of flexible food / pharma / daily-chemical packaging
Vacuum leak test of blister packs, sachets, foil pouches
Sealing test of ampoules, vials, sealed bottles
Confirmation of packaging integrity after drop / pressure tests
QC sampling on production lines or incoming inspection

Sectores

Pharmaceutical and nutraceutical packaging QC
Food and beverage packaging
Cosmetics / personal care
Daily chemical
Medical devices / sterile pouches
Laboratory / R&D

Marcas de componentes

SMC, Japan (core pneumatic components)
VALUE/(FY-1H-N 1 L mini rotary-vane vacuum pump,vacuum-pump variant)
Acrylic vacuum tank (SED in-house)
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Limpieza y mantenimiento

Keep air source dry and clean; regularly clean inlet filter. Drain water from air compressor regularly. Keep equipment and surroundings clean. Periodically check pressure-display accuracy; recalibrate if drift is found (calibration password 3052). Check vacuum-pump oil level — keep between upper and lower marks; replace oil when emulsified or contaminated.

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→