A descrição completa deste modelo ainda está sendo traduzida. Consulte os detalhes em inglês ou solicite informações à nossa equipe. English

SED-STX2-N is a multi-station circulating purification glove box system maintaining an inert (N2 or Ar) atmosphere with water and oxygen levels below 1 ppm (0.1 ppm typical). It integrates a sealed 304 stainless-steel ch

Prazo de entrega
Consultar
Capacidade de produção
Fale conosco

Como funciona

The operation chamber and gas circulation purification system form a sealed working space. Inert gas (Ar or N2) is first purged to displace oxygen and moisture (gas washing). The circulation purification system then continuously removes residual H2O, O2 and organic solvents via a copper catalyst + molecular sieve column, lowering chamber H2O/O2 to <1 ppm. Saturated purification material is automatically regenerated by PLC using a working-gas + 5-10% H2 mixture, enabling unattended operation. High-vacuum solenoid valves (not pneumatic) eliminate pilot-gas pressure requirements, reducing gas consumption. ZrO2 oxygen probe and dew-point water analyzer provide real-time atmosphere monitoring.

Processo de funcionamento
1The operation chamber and gas circulation purification system form a sealed working space.
2Inert gas (Ar or N2) is first purged to displace oxygen and moisture (gas washing).
3The circulation purification system then continuously removes residual H2O, O2 and organic solvents via a copper catalyst + molecular sieve column, lowering chamber H2O/O2 to <1 ppm.
4Saturated purification material is automatically regenerated by PLC using a working-gas + 5-10% H2 mixture, enabling unattended operation.
5High-vacuum solenoid valves (not pneumatic) eliminate pilot-gas pressure requirements, reducing gas consumption.
6ZrO2 oxygen probe and dew-point water analyzer provide real-time atmosphere monitoring.

Especificações técnicas

Especificações da variante: SED-STX2-N

Especificações

Modelo
SED-STX2-N
Utilidades
High-purity Ar (>=99.999%) or N2 (>=99.999%) -- 2 cylinders for single-station, 3-4 for multi-station; Regeneration gas: working gas + 5-10% H2 mixture; Two pressure regulators with 0-25 L/min flow meters and 10 mm OD PU tube fittings; Power supply for PLC, blower, vacuum pump and lighting.
Detalhes de conformidade
Caution: Do not start circulation purification when purification column temperature exceeds 50 degrees C. Do not start circulation purification when chamber O2 level exceeds 400 ppm. Activated carbon adsorber (if fitted) should be replaced approximately every 2 years. Purification material life is 10-15 years under normal use; misoperation (e.g., starting purification at high O2 or high temperature) will damage purification material.

Dimensões

Comprimento
3200 mm
Largura
1200 mm
Altura
1980 mm

Materiais

Materiais de contato
304 aço inoxidável; copper catalyst; molecular sieve; activated carbon
Materiais do corpo
304 aço inoxidável; tempered safety glass (front window)

Características principais

Water content <1 ppm (0.1 ppm typical at standard operation)
Oxygen content <1 ppm (0.1 ppm typical at standard operation)
Leak rate <0.05 vol%/h
Effective oxygen removal >85 L; effective water removal >2 kg
Single-column purification unit (Cu catalyst 8 kg + molecular sieve 16 kg) with one-key PLC automatic regeneration (typical interval >= 12 months)
Purification material life typically 10+ years; regeneration with working gas + 5-10% H2 mixture
Integrated 90 m3/h variable-frequency circulating blower (DARGANG, Taiwan)
ZrO2 oxygen probe (0-1000 ppm, +/-1% ppm) and dew-point water analyzer (0-500 ppm, +/-1% ppm)
Optional activated-carbon organic solvent adsorber (6 kg), parallel to main loop, regenerable by negative-pressure method
Siemens PLC + 7-inch colour touchscreen with multi-level interlocks, leak-rate self-test, password-protected parameters and historical data logging
High-vacuum DN40KF solenoid main valve and solenoid control valves -- no pilot gas required
Leybold D8C vacuum pump (Germany); auto-start or manual via touchscreen
Overall machine dimensions: 3200x1200x1980 mm
Maintains H2O/O2 below 1 ppm (typically 0.1 ppm) -- suitable for the most demanding inert-atmosphere processes
Premium component sourcing: Siemens PLC/HMI, Schneider electrical, Vaisala water analyzer, Leybold D8C vacuum pump, BASF deoxidizer, UOP molecular sieve
PLC one-key automatic regeneration eliminates manual purification material handling
Solenoid (not pneumatic) valves drastically reduce control-gas consumption
Long purification material life (10-15 years) keeps consumable cost low
Multi-level safety interlocks protect both equipment and operator

Aplicações

Inert-atmosphere material handling (lithium, sodium, rare earths)
Battery R&D and pilot lines (Li-ion, sodium-ion, solid-state)
OLED and electronics R&D
Air- and moisture-sensitive chemistry and catalysis research
Powder metallurgy and additive manufacturing under inert gas

Setores

New-energy batteries
Electronics and OLED
University and research labs
Pharmaceuticals and fine chemicals
Material science

Marcas dos componentes

DARGANG (circulating blower, Taiwan)
Vaisala (water/dew-point analyzer, Finland)
ELECTROVAC / Changai assembly (ZrO2 oxygen probe, Germany)
Siemens (PLC controller and colour touchscreen)
Schneider (main electrical and control components, France)
Sailsors (pressure sensor)
UOP (molecular sieve desiccant, USA)
BASF (copper catalyst deoxidizer, Germany)
CKD (high-vacuum solenoid valves, Japan)
Leybold D8C (vacuum pump, Germany)
SED
Fale com SED Sales Team
Especialistas em equipamentos · contato pelo WhatsApp
Consulte o horário e a disponibilidade da equipe

Documentação

Ficha técnica (PDF)
Visão geral do equipamento, especificações e dimensões · Documento original (inglês)
Solicitar à equipe de vendas
Manual do operador
Instalação, operação e diagnóstico · Documento original (inglês)
Solicitar à equipe de vendas
Folha comparativa (Padrão e Econômica)
Comparação das configurações · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos IQ / OQ / PQ
Documentação de validação para conformidade GMP · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos FAT / SAT
Testes de aceitação na fábrica e no local · Documento original (inglês)
Solicitar à equipe de vendas
Desenhos CAD (STEP / IGES / DWG)
Desenhos de engenharia para a instalação · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de calibração
Nível sonoro, resistência de terra, rigidez dielétrica e rugosidade · Documento original (inglês)
Solicitar à equipe de vendas
DQ (qualificação do projeto)
Protocolo completo de qualificação do projeto · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de materiais
Composição do aço inoxidável 316L · Documento original (inglês)
Solicitar à equipe de vendas
SED
WhatsApp · Vendas SED
Contato comercial · WhatsApp
→