Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Boîte à gants à purification par recirculation / Multi-Station Circulating Purification Glove Box System - SED-STX2-N
SED-STX2-N
Sur devis
SED-STX2-N
SED · SED-STX2-N · En vedette

SED-STX2-N — Multi-Station Circulating Purification Glove Box System - SED-STX2-N

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-STX2-N is a multi-station circulating purification glove box system maintaining an inert (N2 or Ar) atmosphere with water and oxygen levels below 1 ppm (0.1 ppm typical). It integrates a sealed 304 stainless-steel ch

Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

The operation chamber and gas circulation purification system form a sealed working space. Inert gas (Ar or N2) is first purged to displace oxygen and moisture (gas washing). The circulation purification system then continuously removes residual H2O, O2 and organic solvents via a copper catalyst + molecular sieve column, lowering chamber H2O/O2 to <1 ppm. Saturated purification material is automatically regenerated by PLC using a working-gas + 5-10% H2 mixture, enabling unattended operation. High-vacuum solenoid valves (not pneumatic) eliminate pilot-gas pressure requirements, reducing gas consumption. ZrO2 oxygen probe and dew-point water analyzer provide real-time atmosphere monitoring.

Processus de fonctionnement
1The operation chamber and gas circulation purification system form a sealed working space.
2Inert gas (Ar or N2) is first purged to displace oxygen and moisture (gas washing).
3The circulation purification system then continuously removes residual H2O, O2 and organic solvents via a copper catalyst + molecular sieve column, lowering chamber H2O/O2 to <1 ppm.
4Saturated purification material is automatically regenerated by PLC using a working-gas + 5-10% H2 mixture, enabling unattended operation.
5High-vacuum solenoid valves (not pneumatic) eliminate pilot-gas pressure requirements, reducing gas consumption.
6ZrO2 oxygen probe and dew-point water analyzer provide real-time atmosphere monitoring.

Caractéristiques techniques

Caractéristiques de la variante : SED-STX2-N

Caractéristiques

Modèle
SED-STX2-N
Fluides et énergie
High-purity Ar (>=99.999%) or N2 (>=99.999%) -- 2 cylinders for single-station, 3-4 for multi-station; Regeneration gas: working gas + 5-10% H2 mixture; Two pressure regulators with 0-25 L/min flow meters and 10 mm OD PU tube fittings; Power supply for PLC, blower, vacuum pump and lighting.
Détails de conformité
Caution: Do not start circulation purification when purification column temperature exceeds 50 degrees C. Do not start circulation purification when chamber O2 level exceeds 400 ppm. Activated carbon adsorber (if fitted) should be replaced approximately every 2 years. Purification material life is 10-15 years under normal use; misoperation (e.g., starting purification at high O2 or high temperature) will damage purification material.

Dimensions

Longueur
3200 mm
Largeur
1200 mm
Hauteur
1980 mm

Matériaux

Matériaux en contact
304 acier inoxydable; copper catalyst; molecular sieve; activated carbon
Matériaux du bâti
304 acier inoxydable; tempered safety glass (front window)

Caractéristiques principales

Water content <1 ppm (0.1 ppm typical at standard operation)
Oxygen content <1 ppm (0.1 ppm typical at standard operation)
Leak rate <0.05 vol%/h
Effective oxygen removal >85 L; effective water removal >2 kg
Single-column purification unit (Cu catalyst 8 kg + molecular sieve 16 kg) with one-key PLC automatic regeneration (typical interval >= 12 months)
Purification material life typically 10+ years; regeneration with working gas + 5-10% H2 mixture
Integrated 90 m3/h variable-frequency circulating blower (DARGANG, Taiwan)
ZrO2 oxygen probe (0-1000 ppm, +/-1% ppm) and dew-point water analyzer (0-500 ppm, +/-1% ppm)
Optional activated-carbon organic solvent adsorber (6 kg), parallel to main loop, regenerable by negative-pressure method
Siemens PLC + 7-inch colour touchscreen with multi-level interlocks, leak-rate self-test, password-protected parameters and historical data logging
High-vacuum DN40KF solenoid main valve and solenoid control valves -- no pilot gas required
Leybold D8C vacuum pump (Germany); auto-start or manual via touchscreen
Overall machine dimensions: 3200x1200x1980 mm
Maintains H2O/O2 below 1 ppm (typically 0.1 ppm) -- suitable for the most demanding inert-atmosphere processes
Premium component sourcing: Siemens PLC/HMI, Schneider electrical, Vaisala water analyzer, Leybold D8C vacuum pump, BASF deoxidizer, UOP molecular sieve
PLC one-key automatic regeneration eliminates manual purification material handling
Solenoid (not pneumatic) valves drastically reduce control-gas consumption
Long purification material life (10-15 years) keeps consumable cost low
Multi-level safety interlocks protect both equipment and operator

Applications

Inert-atmosphere material handling (lithium, sodium, rare earths)
Battery R&D and pilot lines (Li-ion, sodium-ion, solid-state)
OLED and electronics R&D
Air- and moisture-sensitive chemistry and catalysis research
Powder metallurgy and additive manufacturing under inert gas

Secteurs

New-energy batteries
Electronics and OLED
University and research labs
Pharmaceuticals and fine chemicals
Material science

Marques des composants

DARGANG (circulating blower, Taiwan)
Vaisala (water/dew-point analyzer, Finland)
ELECTROVAC / Changai assembly (ZrO2 oxygen probe, Germany)
Siemens (PLC controller and colour touchscreen)
Schneider (main electrical and control components, France)
Sailsors (pressure sensor)
UOP (molecular sieve desiccant, USA)
BASF (copper catalyst deoxidizer, Germany)
CKD (high-vacuum solenoid valves, Japan)
Leybold D8C (vacuum pump, Germany)
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→