Showroom em Ontario, Califórnia · Consulte o suporte para seu destino
Início / Equipamentos / Inspecionadora automática por visão artificial e iluminação (série QYDJ) / Automatic Ampoule Inspection Machine (Lamp Inspection Machine)
SED-600QYDJ-C
Consultar
SED-600QYDJ-C
SED · SED-600QYDJ-C · Em destaque

SED-600QYDJ-C — Automatic Ampoule Inspection Machine

A descrição completa deste modelo ainda está sendo traduzida. Consulte os detalhes em inglês ou solicite informações à nossa equipe. English

SED-600QYDJ-C automatic ampoule inspection machine. 100% machine-vision inspection of 2–100 mL ampoules for visible foreign particles (down to 40 μm, adjustable), seal quality and fill level. Up to 600 vials/min at 2 mL.

FDA-alignedEU cGMP-alignedIEC and ISO drawing standards
Escolher variante (1)
Prazo de entrega
Consultar
Capacidade de produção
500–600 pcs/min (2ml ampoule)

Como funciona

Ampoules are conveyed to an infeed screw, separated, and transferred onto starwheels into multiple inspection stations. At each station the bottle is clamped between an upper and lower head and the servo motor spins it to high speed; the motor brakes suddenly so the liquid keeps rotating by inertia. A Basler industrial camera tracking on a servo-driven moving stage takes sequential images per ampoule. Image-processing software analyzes the motion trajectory of moving objects across the image sequence — air bubbles and noise are filtered out by adjacent-frame continuity, while particles are detected and classified by color/shape/trajectory. The 4 dynamic stations use different rotation/brake profiles and lighting (high-brightness bottom light, slow spin/slow brake, fast spin/fast brake, and back-light for non-reflective particles). Static stations check large bottom particles. After inspection, qualified ampoules go to the qualified channel via starwheel; unqualified ampoules are diverted by negative-pressure vacuum rejection.

Processo de funcionamento
1Ampoules are conveyed to an infeed screw, separated, and transferred onto starwheels into multiple inspection stations.
2At each station the bottle is clamped between an upper and lower head and the servo motor spins it to high speed; the motor brakes suddenly so the liquid keeps rotating by inertia.
3A Basler industrial camera tracking on a servo-driven moving stage takes sequential images per ampoule.
4Image-processing software analyzes the motion trajectory of moving objects across the image sequence — air bubbles and noise are filtered out by adjacent-frame continuity, while particles are detected and classified by color/shape/trajectory.
5The 4 dynamic stations use different rotation/brake profiles and lighting (high-brightness bottom light, slow spin/slow brake, fast spin/fast brake, and back-light for non-reflective particles).
6Static stations check large bottom particles.
7After inspection, qualified ampoules go to the qualified channel via starwheel; unqualified ampoules are diverted by negative-pressure vacuum rejection.

Especificações técnicas

Especificações da variante: Suitable scope: 2R–100H ampoules with relevant change parts

Especificações

Modelo
SED-600QYDJ-C
Capacidade de produção
500–600 pcs/min (2ml ampoule)
Tensão
380V 50Hz 3Φ
Utilidades
380 V AC three-phase five-wire system with good ground wire capacity

Dimensões

Comprimento
3610 mm
Largura
2650 mm
Altura
2000 mm
Peso
3000 kg
Área de instalação
Dimensions 3610 × 2650 × 2000 mm (L×W×H); table height 900 mm; net weight approx. 3000 kg

Características principais

Detects 2–100 mL ampoules (size parts changeable)
Detection accuracy 40 μm (adjustable)
Inspeção speed 500–600 pcs/min @ 2 mL
4 dynamic inspection stations × 4 cameras = 16 cameras + 1 static station × 2 cameras + 2 large-glass cameras
Reflective particle (vitric, white block, fiber) and non-reflective particle (color point, color block, dark block) inspection
Sealing-quality inspection added at station 4
Stroboscopic LED lighting with on-line brightness monitoring (auto-adjusting)
Servo-driven bottle rotation — precise, stable, accurate braking
Up-and-down pressing bottle clamping — neutral position, no bubbles induced; few changeover parts
POM + ceramic quick-loading bottle base (>2-year service life)
Patented large-platen structure separates inspection from drive — easier cleaning, no liquid-ingress risk
Mitsubishi Q-series PLC + 21+ Mitsubishi servos + drivers
Industrial PCs running Win 7/10 with high-speed independent image-processing
Modular plug-in core algorithm for future updates
3-level password access (operator / engineer / administrator)
Real-time diagnosis with optional remote diagnosis
Parameter intelligence auto-tuning from sample images
Image sequence secondary sampling and layered lightness/sorting/zoning algorithm
Negative-pressure vacuum rejection mechanism
Reverse-traceability quality records for FDA / EU cGMP
Table height 900 mm
100% inspection at line speed 600 vpm — no manual inspection bottleneck
FDA / cGMP-aligned reverse-traceability data records
40 μm particle detection with adjustable threshold
Patented large-platen structure for hygienic operation and easy cleaning
Best-in-class component selection: Mitsubishi servo, Basler camera, Ricoh/Computar lens, Schneider, MEAN WELL

Aplicações

Visible foreign particle inspection of injectable ampoules
Fill-level inspection of ampoules
Seal-quality inspection of ampoules
Pharmaceutical injectable line — final inspection station

Setores

Pharmaceutical injectables
Sterile manufacturing
Ampoule production lines

Marcas dos componentes

Servo motors and drivers (HG-SR81, HG-JR353, HG-SR152, HG-KR43, HG-KR23 etc.)
Mitsubishi
PLC CPU / motion CPU / I/O modules (Q170MSCPU-S1, Q173DSCPU, Q03UDE etc.)
Mitsubishi
Industrial cameras (16 units for inspection + 2 large glass)
Basler
Camera lenses
Ricoh / Computar
Industrial PCs
Advantech
Display screen
Nordja
Lighting (bottom light / backlight)
Weilang / Jiali / Sharp Vision
Switching power supply (LRS-350-24, LRS-200-12 etc.)
MEAN WELL
Circuit breakers / control box / power switch
Schneider / APT
UPS (H2000)
Radius
Solid-state relay (TOS 24DVC)
Weidmüller
Small relay (SR-1C-AD24V-E)
Honeywell
Speed motor / governor (SPC200E / 200YT01)
Refining
Proximity / photoelectric switch
Mach
SED
Fale com SED Sales Team
Especialistas em equipamentos · contato pelo WhatsApp
Consulte o horário e a disponibilidade da equipe

Conformidade

FDA-aligned
EU cGMP-aligned
IEC and ISO drawing standards

Documentação

Ficha técnica (PDF)
Visão geral do equipamento, especificações e dimensões · Documento original (inglês)
Solicitar à equipe de vendas
Manual do operador
Instalação, operação e diagnóstico · Documento original (inglês)
Solicitar à equipe de vendas
Folha comparativa (Padrão e Econômica)
Comparação das configurações · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos IQ / OQ / PQ
Documentação de validação para conformidade GMP · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos FAT / SAT
Testes de aceitação na fábrica e no local · Documento original (inglês)
Solicitar à equipe de vendas
Desenhos CAD (STEP / IGES / DWG)
Desenhos de engenharia para a instalação · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de calibração
Nível sonoro, resistência de terra, rigidez dielétrica e rugosidade · Documento original (inglês)
Solicitar à equipe de vendas
DQ (qualificação do projeto)
Protocolo completo de qualificação do projeto · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de materiais
Composição do aço inoxidável 316L · Documento original (inglês)
Solicitar à equipe de vendas
SED
WhatsApp · Vendas SED
Contato comercial · WhatsApp
→