Showroom em Ontario, Califórnia · Consulte o suporte para seu destino
Início / Equipamentos / Autoclave de vácuo pulsante / SED-0.8MM-J Pulsating-Vacuum Sterilizer (Gas-Sealed Double-Leaf Motorized Doors)
SED-0.8MM-J
Consultar
SED-0.8MM-J
SED · SED-0.8MM-J · Em destaque

SED-0.8MM-J — SED-0.8MM-J Pulsating-Vacuum Sterilizer

A descrição completa deste modelo ainda está sendo traduzida. Consulte os detalhes em inglês ou solicite informações à nossa equipe. English

SED-0.8MM-J pulsating-vacuum (saturated steam) sterilizer/autoclave — gas-sealed, double-leaf motorized pass-through doors. Horizontal inner-outer double-shell design: inner chamber 6 mm SUS304 SS; outer jacket 6 mm Q345

GB 150.1/2/3/4-2011 (Chinese steel pressure vessel code, Class I)GMP-compliant design with standard validation interfaces
Escolher variante (2)
Prazo de entrega
Consultar
Capacidade de produção
Fale conosco

Como funciona

Saturated steam is the sterilization medium. Before the sterilization phase, the cycle pulsates vacuum and steam several times to evacuate residual cold air from load crevices, ensuring uniform heat penetration throughout porous loads (textiles, dressings). The working temperature (139 °C) and pressure (0.25 MPa) are maintained for the configured hold time. Temperature is monitored by two Pt100 probes (chamber and in-load). Cycle data (pressure, temperature, time, F0) are printed by the EPSON-chip micro printer.

Processo de funcionamento
1Saturated steam is the sterilization medium.
2Before the sterilization phase, the cycle pulsates vacuum and steam several times to evacuate residual cold air from load crevices, ensuring uniform heat penetration throughout porous loads (textiles, dressings).
3The working temperature (139 °C) and pressure (0.25 MPa) are maintained for the configured hold time.
4Temperature is monitored by two Pt100 probes (chamber and in-load).
5Cycle data (pressure, temperature, time, F0) are printed by the EPSON-chip micro printer.

Especificações técnicas

Especificações da variante: SED-0 chamber 1400×680×850 mm

Especificações

Modelo
SED-0.8MM-J
Tensão
AC380V/220V 50Hz, 3-phase 5-wire
Utilidades
Drinking-grade water: 0.1–0.3 MPa, ~220 kg per cycle; Plant steam: 0.4–0.6 MPa, ~40 kg per cycle; Compressed air: 0.5–0.7 MPa; Electrical: AC380V/220V 50Hz, 3-phase 5-wire, 2.5 kW.
Detalhes de conformidade
Chamber and jacket designed and built to GB 150.1/2/3/4-2011 (Class I pressure vessel). X-ray weld inspection with full quality certificates. Sanitary 304 SS tubing and tri-clover connections throughout utility lines. Pneumatic angle-seat valves replace check valves on steam-trap line to prevent cross-contamination.
Potência
2.5 kW
Pressão de ar
Working pressure 0.25 MPa; design pressure 0.3 MPa; ultimate vacuum -0.095 MPa; working temperature 139 °C

Dimensões

Comprimento
1680 mm
Largura
1400 mm
Altura
1920 mm
Peso
1400 kg
Área de instalação
1680 × 1400 × 1920 mm (L×W×H), net weight 1400 kg. Pass-through configuration requires barrier-wall opening sized to outer envelope.

Materiais

Materiais de contato
SUS304 stainless steel (6 mm inner chamber, 8 mm door panels, sanitary tubing, sterilization cart and transport carts); medical-grade pharmaceutical-grade silicone gaskets
Materiais do corpo
SUS304 stainless steel (chamber); Q345R pressure-vessel steel (outer jacket); 1.2 mm 304 oil-ground brushed stainless decorative outer panels

Características principais

Gas-sealed double-leaf motorized pass-through doors with safety + pressure interlocks
Inner chamber 6 mm SUS304; outer jacket 6 mm Q345R pressure-vessel steel; door panels 8 mm 304 SS
Medical-grade pharmaceutical-grade silicone door gasket, compressed-air automatic sealing
Pulsating-vacuum air removal — eliminates cold-air pockets for uniform sterilization of porous loads
Heat uniformity ≤ ±1 °C; ultimate vacuum -0.095 MPa
Working temperature 139 °C, working pressure 0.25 MPa (design 144 °C / 0.3 MPa)
GMP-validated design with standard validation interfaces; X-ray weld inspection on chamber welds
Two Pt100 temperature probes (chamber + in-load liquid)
Real-time pressure/temperature/time/F0 reporting via EPSON-chip micro printer; touchscreen with electronic-signature and admin permissions
Sanitary 304 SS tubing, tri-clover quick-clamp connections throughout
Pneumatic angle-seat valves on steam-trap line — prevents reverse cross-contamination
50 mm aluminum-silicate insulation; 1.2 mm 304 brushed-stainless decorative outer panels
Includes 1 × 304 SS sterilization cart + 2 × 304 SS transport carts
Designed and validated to Chinese GMP; suitable for pharmaceutical sterile manufacturing and hospital CSSD use
Premium imported instrumentation: Siemens PLC, ASCO valves, HUBA pressure transmitter, B+B / Ereith Pt100
Pulsating vacuum cycle ensures uniform sterilization of porous loads (textiles, dressings)
Pass-through design allows clean / non-clean barrier separation
Sanitary internal tubing with tri-clover connections meets pharmaceutical clean-utility requirements

Aplicações

Sterilization of clothing, dressings and textiles (porous loads)
Sterilization of metal surgical instruments
Sterilization of culture media
Sterilization of laboratory glassware
Hospital CSSD and pharmaceutical sterile-area sterilization

Setores

Pharmaceutical (sterile / injectable)
Hospital / CSSD
Health and scientific research
Microbiology / culture media laboratories

Marcas dos componentes

Siemens Germany (PLC S7-200)
ASCO USA (angle-seat pneumatic valves, 4 million-cycle life)
HUBA Switzerland (pressure transmitter)
B+B Germany (Pt100 soft temperature probe)
Ereith (Pt100 hard temperature probe)
Airtac Taiwan (solenoid valves)
TRE / Pingtong Taiwan (touchscreen with curve-print function)
Weihuang Beijing (micro printer with EPSON chip)
Brady Beijing (pressure gauges)
Yulong Shanghai (water-ring vacuum pump)
Jiangsu Santong (0.22 μm sterile air filter)
Zhongzhi CIS (steam trap)
Guangyi Zhejiang (safety valve, 0.1–0.3 MPa)
SED
Fale com SED Sales Team
Especialistas em equipamentos · contato pelo WhatsApp
Consulte o horário e a disponibilidade da equipe

Conformidade

GB 150.1/2/3/4-2011 (Chinese steel pressure vessel code, Class I)
GMP-compliant design with standard validation interfaces

Documentação

Ficha técnica (PDF)
Visão geral do equipamento, especificações e dimensões · Documento original (inglês)
Solicitar à equipe de vendas
Manual do operador
Instalação, operação e diagnóstico · Documento original (inglês)
Solicitar à equipe de vendas
Folha comparativa (Padrão e Econômica)
Comparação das configurações · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos IQ / OQ / PQ
Documentação de validação para conformidade GMP · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos FAT / SAT
Testes de aceitação na fábrica e no local · Documento original (inglês)
Solicitar à equipe de vendas
Desenhos CAD (STEP / IGES / DWG)
Desenhos de engenharia para a instalação · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de calibração
Nível sonoro, resistência de terra, rigidez dielétrica e rugosidade · Documento original (inglês)
Solicitar à equipe de vendas
DQ (qualificação do projeto)
Protocolo completo de qualificação do projeto · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de materiais
Composição do aço inoxidável 316L · Documento original (inglês)
Solicitar à equipe de vendas
SED
WhatsApp · Vendas SED
Contato comercial · WhatsApp
→