Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Remplisseuse linéaire de liquides à 8 têtes / Syrup Equipment - Syrup Filling and Capping Machine - Linear Liquid Filling Machine
SED-8YTG-H
Sur devis
SED-8YTG-H
SED · SED-8YTG-H · En vedette

SED-8YTG-H — Syrup Equipment - Syrup Filling and Capping Machine - Linear Liquid Filling Machine

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

Fully automatic 8-head linear liquid filling line. Anti-corrosion stainless steel gear pump filling, glass check-valve anti-drip design, linear bottle infeed for wide packaging compatibility. Lifting/submerging nozzle fi

Délai de livraison
Sur devis
Cadence
80–100 flacons/min

Fonctionnement

Gear-pump draw-and-fill system with lifting/submerging nozzle design to prevent foaming. Bottles travel on a chain-plate conveyor in a linear layout. Photoelectric sensors detect bottle count; front and rear gates control bottle entry/exit to the filling zone. Each of the 8 filling nozzles operates independently with individually programmable fill time. Sanitary glass check-valves mid-pipe prevent drip. Operational parameters (timing for each motion: bottle entry delay, exit delay, early rise, delayed descent, gate delays, drip-tray open/close delays) are fully configurable from the HMI.

Processus de fonctionnement
1Gear-pump draw-and-fill system with lifting/submerging nozzle design to prevent foaming.
2Bottles travel on a chain-plate conveyor in a linear layout.
3Photoelectric sensors detect bottle count; front and rear gates control bottle entry/exit to the filling zone.
4Each of the 8 filling nozzles operates independently with individually programmable fill time.
5Sanitary glass check-valves mid-pipe prevent drip.
6Operational parameters (timing for each motion: bottle entry delay, exit delay, early rise, delayed descent, gate delays, drip-tray open/close delays) are fully configurable from the HMI.

Caractéristiques techniques

Caractéristiques de la variante : SED-8YTG-H

Caractéristiques

Modèle
SED-8YTG-H
Cadence
80–100 flacons/min
Tension
220V 50Hz
Puissance
2 kW

Dimensions

Longueur
2000 mm
Largeur
1000 mm
Hauteur
1570 mm
Poids
220 kg

Matériaux

Matériaux en contact
316 acier inoxydable gear pump; sanitary glass check-valves
Matériaux du bâti
Stainless steel integrated body; chain-plate conveyor

Caractéristiques principales

Anti-corrosion stainless steel gear pump filling — easy cleaning and hose replacement
Glass check-valve anti-drip — minimizes dripping
Linear bottle infeed — compatible with wide range of bottle types
Auto bottle in/out sensing — set fill count, flexible enable/disable of individual nozzles
Each nozzle independently operable
Lifting/submerging nozzle filling — prevents foaming
Stainless steel integrated body, chain-plate bottle conveyor
8 filling heads; single-head max flow 5 L/min
Bottle width range 15–150 mm, height range 40–3200 mm
Compact footprint — suitable for various production environments
8-head simultaneous filling — 80–100 bottles/min high throughput
Anti-corrosion stainless steel gear pump — handles acids/alkalis
Wide packaging compatibility — easy bottle changeover
Glass check-valve anti-drip — improves yield
Per-pump independent fill time and volume setting
Linear compact design — small footprint, flexible installation

Applications

Alcohol and disinfectant filling
Essential oils, toner, makeup remover, serums
White liquor, mineral water, edible oil
Pharmaceutical reagents and medical liquids
Chemical product dispensing

Secteurs

Pharmaceutique
Food
Cosmétiques
Daily chemical
Chemical
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Nettoyage et entretien

Periodically inspect and clean the feed pipe filter screen to prevent foreign matter from entering the pump head. Periodically check the glass check-valve return status — replace if return is not smooth. If the machine is idle for an extended period, drain and clean the pipe contents, then fill with purified water to maintain pump body moisture. Before restarting after long idle, use the supplied syringe to prime liquid to above the pump body level to avoid dry-friction gear wear. Periodically drain moisture from the compressed-air supply to protect pneumatic components.

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→