Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Ligne intégrée blister et mise en étui / Pre-Filled Syringe Blister Packing & Cartoning Line
SED-80PZ1-V
Sur devis
SED-80PZ1-V
SED · SED-80PZ1-V · En vedette

SED-80PZ1-V — Pre-Filled Syringe Blister Packing & Cartoning Line

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-80PZ1-V Pre-Filled Syringe Blister Packing & Cartoning Line. Complete pre-filled syringe blister + cartoning line with Yamaha robot feeder,1 set mold,cooling chiller,aluminum-profile safety guarding,IQ/OQ/PQ + FAT/SA

GMP
Choisir une variante (2)
Délai de livraison
Sur devis
Cadence
70–80 cartons/min

Fonctionnement

Pre-filled syringes leave the upstream labeling machine and enter the mechanical feeder: clamping belts lift the syringe up an incline; storage section buffers and pitches them; a servo-driven screw conveyor presents one syringe per pitch to the suction head; a suction cylinder grabs the syringe, then a rotary cylinder corrects orientation; the head deposits the syringe into the formed blister cavity. PVC sheet is thermoformed; pressure-boost cylinder seals foil at 165 °C (adjustable); water-chiller circulates cooling water. Camera vision system inspects each blister for syringe presence and orientation; faulty blisters are rejected. Die-cut blisters proceed to ZHW-100 cartoner for vacuum carton erecting, leaflet folding/insertion, blister+leaflet inserting, end-flap closing, pharmacode verification, steel-letter coding, and reject for missing parts.

Processus de fonctionnement
1Pre-filled syringes leave the upstream labeling machine and enter the mechanical feeder: clamping belts lift the syringe up an incline; storage section buffers and pitches them; a servo-driven screw conveyor presents one syringe per pitch to the suction head; a suction cylinder grabs the syringe, then a rotary cylinder corrects orientation; the head deposits the syringe into the formed blister cavity.
2PVC sheet is thermoformed; pressure-boost cylinder seals foil at 165 °C (adjustable); water-chiller circulates cooling water.
3Camera vision system inspects each blister for syringe presence and orientation; faulty blisters are rejected.
4Die-cut blisters proceed to ZHW-100 cartoner for vacuum carton erecting, leaflet folding/insertion, blister+leaflet inserting, end-flap closing, pharmacode verification, steel-letter coding, and reject for missing parts.

Caractéristiques techniques

Caractéristiques de la variante : SED-80PZ-V (vial blister line)

Caractéristiques

Modèle
SED-80PZ1-V
Cadence
70–80 cartons/min
Tension
AC380V, 50Hz
Fluides et énergie
Compressed air ≥0.22 m³/min (customer-supplied); cooling water for chiller
Puissance
7 kW
Pression d’air
0.6-0.8Mpa

Dimensions

Longueur
4800 mm
Largeur
1250 mm
Hauteur
1650 mm
Poids
3300 kg

Matériaux

Matériaux en contact
PVC (blister forming material)
Matériaux du bâti
acier inoxydable

Caractéristiques principales

Complete pre-filled syringe blister + cartoning line
Mechanical feeder directly couples to upstream labeling machine
Yamaha robot + screw feeder + suction-and-rotate placer for syringe orientation
Servo-controlled traction (60-152 mm stroke)
Max forming area 255×175 mm × 30 mm depth
Punch frequency 15-22 cuts/min
Pressure-boost cylinder sealing at 165 °C base (adjustable)
Water-chiller cooling
Camera vision detection system standard
Cartoner 70-80 cartons/min, carton 65×35×18 to 150×120×50 mm, paper 250-300 g/m²
Auto-reject missing blister/syringe/leaflet/coder
IQ/OQ/PQ/FAT/SAT documentation
Designed specifically for pre-filled syringe handling (orientation correction, soft suction)
Direct labeling-line coupling — no manual handling
European/Japanese branded electrics and pneumatics throughout
12-14 month warranty + on-site installation/training

Applications

Pre-filled syringe blister packaging and cartoning
Pre-filled syringe + needle + vial multi-cavity blisters

Secteurs

Pharmaceutical (injectables)
Biopharmaceutical
Vaccine packaging

Marques des composants

Vial/syringe robot feeder
Yamaha
PLC / HMI / circuit breakers / main motor
Siemens
Inverter
Omron 3G3JZ
Servo drives / motors / relays / E-stop / alarm light
Schneider
Solenoid / vacuum valves / FRL / pressure switch
SMC
Vacuum pump
Becker WEA90S2-4
Pharmacode reader (option)
Laetus 6012
Hot-melt glue station (option)
Nordson Mesa 6
Cartoner main motor
Dongli
Cartoner safety switches
Omron D4NA-4131
Encoders / proximity / power switches
Omron
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

GMP

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→