Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
Startseite / Maschinen / Blister- und Kartonier-Verbundlinie / Pre-Filled Syringe Blister Packing & Cartoning Line
SED-80PZ1-V
Auf Anfrage
SED-80PZ1-V
SED · SED-80PZ1-V · Hervorgehoben

SED-80PZ1-V — Pre-Filled Syringe Blister Packing & Cartoning Line

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-80PZ1-V Pre-Filled Syringe Blister Packing & Cartoning Line. Complete pre-filled syringe blister + cartoning line with Yamaha robot feeder,1 set mold,cooling chiller,aluminum-profile safety guarding,IQ/OQ/PQ + FAT/SA

GMP
Variante wählen (2)
Lieferzeit
Auf Anfrage
Durchsatz
70–80 cartons/min

Funktionsweise

Pre-filled syringes leave the upstream labeling machine and enter the mechanical feeder: clamping belts lift the syringe up an incline; storage section buffers and pitches them; a servo-driven screw conveyor presents one syringe per pitch to the suction head; a suction cylinder grabs the syringe, then a rotary cylinder corrects orientation; the head deposits the syringe into the formed blister cavity. PVC sheet is thermoformed; pressure-boost cylinder seals foil at 165 °C (adjustable); water-chiller circulates cooling water. Camera vision system inspects each blister for syringe presence and orientation; faulty blisters are rejected. Die-cut blisters proceed to ZHW-100 cartoner for vacuum carton erecting, leaflet folding/insertion, blister+leaflet inserting, end-flap closing, pharmacode verification, steel-letter coding, and reject for missing parts.

Prozessbeschreibung
1Pre-filled syringes leave the upstream labeling machine and enter the mechanical feeder: clamping belts lift the syringe up an incline; storage section buffers and pitches them; a servo-driven screw conveyor presents one syringe per pitch to the suction head; a suction cylinder grabs the syringe, then a rotary cylinder corrects orientation; the head deposits the syringe into the formed blister cavity.
2PVC sheet is thermoformed; pressure-boost cylinder seals foil at 165 °C (adjustable); water-chiller circulates cooling water.
3Camera vision system inspects each blister for syringe presence and orientation; faulty blisters are rejected.
4Die-cut blisters proceed to ZHW-100 cartoner for vacuum carton erecting, leaflet folding/insertion, blister+leaflet inserting, end-flap closing, pharmacode verification, steel-letter coding, and reject for missing parts.

Technische Daten

Technische Daten für Variante: SED-80PZ-V (vial blister line)

Technische Daten

Modell
SED-80PZ1-V
Durchsatz
70–80 cartons/min
Spannung
AC380V, 50Hz
Versorgung
Compressed air ≥0.22 m³/min (customer-supplied); cooling water for chiller
Leistung
7 kW
Luftdruck
0.6-0.8Mpa

Abmessungen

Länge
4800 mm
Breite
1250 mm
Höhe
1650 mm
Gewicht
3300 kg

Werkstoffe

Kontaktwerkstoffe
PVC (blister forming material)
Gehäusewerkstoffe
Edelstahl

Wesentliche Merkmale

Complete pre-filled syringe blister + cartoning line
Mechanical feeder directly couples to upstream labeling machine
Yamaha robot + screw feeder + suction-and-rotate placer for syringe orientation
Servo-controlled traction (60-152 mm stroke)
Max forming area 255×175 mm × 30 mm depth
Punch frequency 15-22 cuts/min
Pressure-boost cylinder sealing at 165 °C base (adjustable)
Water-chiller cooling
Camera vision detection system standard
Cartoner 70-80 cartons/min, carton 65×35×18 to 150×120×50 mm, paper 250-300 g/m²
Auto-reject missing blister/syringe/leaflet/coder
IQ/OQ/PQ/FAT/SAT documentation
Designed specifically for pre-filled syringe handling (orientation correction, soft suction)
Direct labeling-line coupling — no manual handling
European/Japanese branded electrics and pneumatics throughout
12-14 month warranty + on-site installation/training

Anwendungen

Pre-filled syringe blister packaging and cartoning
Pre-filled syringe + needle + vial multi-cavity blisters

Branchen

Pharmaceutical (injectables)
Biopharmaceutical
Vaccine packaging

Komponentenhersteller

Vial/syringe robot feeder
Yamaha
PLC / HMI / circuit breakers / main motor
Siemens
Inverter
Omron 3G3JZ
Servo drives / motors / relays / E-stop / alarm light
Schneider
Solenoid / vacuum valves / FRL / pressure switch
SMC
Vacuum pump
Becker WEA90S2-4
Pharmacode reader (option)
Laetus 6012
Hot-melt glue station (option)
Nordson Mesa 6
Cartoner main motor
Dongli
Cartoner safety switches
Omron D4NA-4131
Encoders / proximity / power switches
Omron
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

GMP

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→