Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
SED-72ZQ-J
Sur devis
SED-72ZQ-J
SED · SED-72ZQ-J · En vedette

SED-72ZQ-J — Electric Steam Generator

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-72ZQ-J 72 kW clean-type electric steam generator (304 stainless steel series). Rated steam output 100 kg/h, saturated steam temperature 171°C, rated pressure 0.7 MPa. Heating is delivered by four 18 kW heater banks (

CEBoiler-use license exempt (China)
Délai de livraison
Sur devis
Cadence
100 kg/h (steam output)

Fonctionnement

Resistive electrical heating: feed water (must be chloride-free, deionized) is pumped into a stainless boiler vessel; four parallel 316L SS heater elements (18 kW each, controlled in stages) heat the water to saturation pressure (0.7 MPa, 171°C). Multi-level water-level sensors prevent dry heating; dual pressure switches cut power if pressure exceeds set point; safety valve set at 0.73 MPa for full-open pressure relief; boiler-wall temperature sensor cuts power and alarms if wall temperature exceeds 165°C.

Processus de fonctionnement
1Resistive electrical heating: feed water (must be chloride-free, deionized) is pumped into a stainless boiler vessel; four parallel 316L SS heater elements (18 kW each, controlled in stages) heat the water to saturation pressure (0.7 MPa, 171°C).
2Multi-level water-level sensors prevent dry heating; dual pressure switches cut power if pressure exceeds set point; safety valve set at 0.73 MPa for full-open pressure relief; boiler-wall temperature sensor cuts power and alarms if wall temperature exceeds 165°C.

Caractéristiques techniques

Caractéristiques de la variante : SED-72ZQ-J

Caractéristiques

Modèle
SED-72ZQ-J
Cadence
100 kg/h (steam output)
Tension
380V 50Hz 3Φ
Puissance
72 kW
Pression d’air
0.7 MPa (rated steam pressure); safety set 0.73 MPa

Dimensions

Longueur
850 mm
Largeur
620 mm
Hauteur
1450 mm

Matériaux

Matériaux en contact
304 stainless steel (boiler vessel and pipework, valves); 316L stainless steel (heating element sheath)
Matériaux du bâti
Anti-corrosion treated steel cabinet; 304 stainless steel boiler shell

Caractéristiques principales

Rated heating power 72 kW
Steam output 100 kg/h, saturated steam temperature 171°C
Rated steam pressure 0.7 MPa (safety valve at 0.73 MPa)
Four 18 kW heater banks for 4-stage load modulation
316L SS thick-wall seamless tube heaters with high-temp magnesium powder, rated to 1000°C
Water volume <30 L — exempt from China boiler-use license
304 SS boiler vessel and all pipework / valves
Water-electricity separated cabinet (insulation/waterproof)
Overall dimensions 850×620×1450 mm (L×W×H)
Steam/water/blowdown ports all DN20
Bangpu LCD controller (RS-485) with full-status display
Multi-level water-level sensors (prevent dry heating)
Dual pressure control + safety valve at 0.73 MPa
Boiler-wall over-temperature protection (≥165°C auto cut + alarm)
High-pressure pump: Aolong stainless steel pump head
CE certified
Pre-tested at factory; plug-and-play startup
Clean-type stainless construction suitable for pharmaceutical / food clean steam
CE certificate provided
No boiler-use license required (water volume below 30 L threshold)
Energy savings via 4-stage load modulation based on steam demand
Comprehensive multi-level safety interlocks

Applications

Pharmaceutical clean steam supply
Food and beverage steam generation
Cosmetic / personal care production steam
Laboratory steam supply
Sterilization steam

Secteurs

Pharmaceutique
Agroalimentaire et boissons
Cosmétiques
Laboratoire
General manufacturing

Marques des composants

LCD boiler controller (RS-485)
Guangzhou Bangpu
Residual-current breaker (RCBO)
Chint
AC contactor
LS (Korea)
High-pressure feed pump (SS pump head)
Aolong
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

CE
Boiler-use license exempt (China)

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→