Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
SED-72ZQ-J
Auf Anfrage
SED-72ZQ-J
SED · SED-72ZQ-J · Hervorgehoben

SED-72ZQ-J — Electric Steam Generator

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-72ZQ-J 72 kW clean-type electric steam generator (304 stainless steel series). Rated steam output 100 kg/h, saturated steam temperature 171°C, rated pressure 0.7 MPa. Heating is delivered by four 18 kW heater banks (

CEBoiler-use license exempt (China)
Lieferzeit
Auf Anfrage
Durchsatz
100 kg/h (steam output)

Funktionsweise

Resistive electrical heating: feed water (must be chloride-free, deionized) is pumped into a stainless boiler vessel; four parallel 316L SS heater elements (18 kW each, controlled in stages) heat the water to saturation pressure (0.7 MPa, 171°C). Multi-level water-level sensors prevent dry heating; dual pressure switches cut power if pressure exceeds set point; safety valve set at 0.73 MPa for full-open pressure relief; boiler-wall temperature sensor cuts power and alarms if wall temperature exceeds 165°C.

Prozessbeschreibung
1Resistive electrical heating: feed water (must be chloride-free, deionized) is pumped into a stainless boiler vessel; four parallel 316L SS heater elements (18 kW each, controlled in stages) heat the water to saturation pressure (0.7 MPa, 171°C).
2Multi-level water-level sensors prevent dry heating; dual pressure switches cut power if pressure exceeds set point; safety valve set at 0.73 MPa for full-open pressure relief; boiler-wall temperature sensor cuts power and alarms if wall temperature exceeds 165°C.

Technische Daten

Technische Daten für Variante: SED-72ZQ-J

Technische Daten

Modell
SED-72ZQ-J
Durchsatz
100 kg/h (steam output)
Spannung
380V 50Hz 3Φ
Leistung
72 kW
Luftdruck
0.7 MPa (rated steam pressure); safety set 0.73 MPa

Abmessungen

Länge
850 mm
Breite
620 mm
Höhe
1450 mm

Werkstoffe

Kontaktwerkstoffe
304 stainless steel (boiler vessel and pipework, valves); 316L stainless steel (heating element sheath)
Gehäusewerkstoffe
Anti-corrosion treated steel cabinet; 304 stainless steel boiler shell

Wesentliche Merkmale

Rated heating power 72 kW
Steam output 100 kg/h, saturated steam temperature 171°C
Rated steam pressure 0.7 MPa (safety valve at 0.73 MPa)
Four 18 kW heater banks for 4-stage load modulation
316L SS thick-wall seamless tube heaters with high-temp magnesium powder, rated to 1000°C
Water volume <30 L — exempt from China boiler-use license
304 SS boiler vessel and all pipework / valves
Water-electricity separated cabinet (insulation/waterproof)
Overall dimensions 850×620×1450 mm (L×W×H)
Steam/water/blowdown ports all DN20
Bangpu LCD controller (RS-485) with full-status display
Multi-level water-level sensors (prevent dry heating)
Dual pressure control + safety valve at 0.73 MPa
Boiler-wall over-temperature protection (≥165°C auto cut + alarm)
High-pressure pump: Aolong stainless steel pump head
CE certified
Pre-tested at factory; plug-and-play startup
Clean-type stainless construction suitable for pharmaceutical / food clean steam
CE certificate provided
No boiler-use license required (water volume below 30 L threshold)
Energy savings via 4-stage load modulation based on steam demand
Comprehensive multi-level safety interlocks

Anwendungen

Pharmaceutical clean steam supply
Food and beverage steam generation
Cosmetic / personal care production steam
Laboratory steam supply
Sterilization steam

Branchen

Pharma
Lebensmittel und Getränke
Kosmetik
Labor
General manufacturing

Komponentenhersteller

LCD boiler controller (RS-485)
Guangzhou Bangpu
Residual-current breaker (RCBO)
Chint
AC contactor
LS (Korea)
High-pressure feed pump (SS pump head)
Aolong
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

CE
Boiler-use license exempt (China)

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→