SED-72ZQ-J — Electric Steam Generator

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-72ZQ-J 72 kW clean-type electric steam generator (304 stainless steel series). Rated steam output 100 kg/h, saturated steam temperature 171°C, rated pressure 0.7 MPa. Heating is delivered by four 18 kW heater banks (

CEBoiler-use license exempt (China)
Plazo de entrega
Consultar
Capacidad de producción
100 kg/h (steam output)

Funcionamiento

Resistive electrical heating: feed water (must be chloride-free, deionized) is pumped into a stainless boiler vessel; four parallel 316L SS heater elements (18 kW each, controlled in stages) heat the water to saturation pressure (0.7 MPa, 171°C). Multi-level water-level sensors prevent dry heating; dual pressure switches cut power if pressure exceeds set point; safety valve set at 0.73 MPa for full-open pressure relief; boiler-wall temperature sensor cuts power and alarms if wall temperature exceeds 165°C.

Proceso de funcionamiento
1Resistive electrical heating: feed water (must be chloride-free, deionized) is pumped into a stainless boiler vessel; four parallel 316L SS heater elements (18 kW each, controlled in stages) heat the water to saturation pressure (0.7 MPa, 171°C).
2Multi-level water-level sensors prevent dry heating; dual pressure switches cut power if pressure exceeds set point; safety valve set at 0.73 MPa for full-open pressure relief; boiler-wall temperature sensor cuts power and alarms if wall temperature exceeds 165°C.

Especificaciones técnicas

Especificaciones de la variante: SED-72ZQ-J

Especificaciones

Modelo
SED-72ZQ-J
Capacidad de producción
100 kg/h (steam output)
Tensión
380V 50Hz 3Φ
Potencia
72 kW
Presión de aire
0.7 MPa (rated steam pressure); safety set 0.73 MPa

Dimensiones

Longitud
850 mm
Anchura
620 mm
Altura
1450 mm

Materiales

Materiales en contacto
304 stainless steel (boiler vessel and pipework, valves); 316L stainless steel (heating element sheath)
Materiales del cuerpo
Anti-corrosion treated steel cabinet; 304 stainless steel boiler shell

Características principales

Rated heating power 72 kW
Steam output 100 kg/h, saturated steam temperature 171°C
Rated steam pressure 0.7 MPa (safety valve at 0.73 MPa)
Four 18 kW heater banks for 4-stage load modulation
316L SS thick-wall seamless tube heaters with high-temp magnesium powder, rated to 1000°C
Water volume <30 L — exempt from China boiler-use license
304 SS boiler vessel and all pipework / valves
Water-electricity separated cabinet (insulation/waterproof)
Overall dimensions 850×620×1450 mm (L×W×H)
Steam/water/blowdown ports all DN20
Bangpu LCD controller (RS-485) with full-status display
Multi-level water-level sensors (prevent dry heating)
Dual pressure control + safety valve at 0.73 MPa
Boiler-wall over-temperature protection (≥165°C auto cut + alarm)
High-pressure pump: Aolong stainless steel pump head
CE certified
Pre-tested at factory; plug-and-play startup
Clean-type stainless construction suitable for pharmaceutical / food clean steam
CE certificate provided
No boiler-use license required (water volume below 30 L threshold)
Energy savings via 4-stage load modulation based on steam demand
Comprehensive multi-level safety interlocks

Aplicaciones

Pharmaceutical clean steam supply
Food and beverage steam generation
Cosmetic / personal care production steam
Laboratory steam supply
Sterilization steam

Sectores

Farmacéutico
Alimentación y bebidas
Cosméticos
Laboratorio
General manufacturing

Marcas de componentes

LCD boiler controller (RS-485)
Guangzhou Bangpu
Residual-current breaker (RCBO)
Chint
AC contactor
LS (Korea)
High-pressure feed pump (SS pump head)
Aolong
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

CE
Boiler-use license exempt (China)

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→