Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
SED-60ZQ-J
Sur devis
SED-60ZQ-J
SED · SED-60ZQ-J · En vedette

SED-60ZQ-J — Electric Steam Generator

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-60ZQ-J 60kW inspection-exempt electric steam generator. Water capacity below 30L — within the national exemption from boiler-use license. Rated steam output 85kg/h, saturated steam temperature 171°C, rated pressure 0

CEBoiler-use license exempt (water capacity <30L)
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Water is loaded into the boiler body. Depending on steam demand, one, two or all three 20kW heating element groups are activated. The elements heat the water to produce saturated steam (171°C / 0.7MPa) which is delivered through the DN15 steam outlet. Three-level water-level control (high/mid/low) prevents dry-burn on water stoppage; dual pressure controllers automatically cut power if pressure exceeds the set point; a full-lift safety valve opens at 0.73MPa for additional pressure relief; a wall-temperature sensor cuts power and triggers an alarm if the furnace wall exceeds 165°C.

Processus de fonctionnement
1Water is loaded into the boiler body.
2Depending on steam demand, one, two or all three 20kW heating element groups are activated.
3The elements heat the water to produce saturated steam (171°C / 0.7MPa) which is delivered through the DN15 steam outlet.
4Three-level water-level control (high/mid/low) prevents dry-burn on water stoppage; dual pressure controllers automatically cut power if pressure exceeds the set point; a full-lift safety valve opens at 0.73MPa for additional pressure relief; a wall-temperature sensor cuts power and triggers an alarm if the furnace wall exceeds 165°C.

Caractéristiques techniques

Caractéristiques de la variante : SED-60ZQ-J

Caractéristiques

Modèle
SED-60ZQ-J
Tension
380V 50Hz 3Φ
Puissance
60 kW

Dimensions

Longueur
790 mm
Largeur
520 mm
Hauteur
1260 mm

Matériaux

Matériaux en contact
316L seamless stainless-steel heating tubes
Matériaux du bâti
Anti-corrosion-treated boiler body and fittings

Caractéristiques principales

Boiler-use license exempt (water capacity <30L)
Three independent 20kW heating-tube groups with stepped adjustment
Each group equipped with its own leakage circuit breaker
316L seamless SS heating tubes + imported high-temperature magnesium powder, rated 1000°C
Flange-type assembly for easy tube replacement
Water-electricity separated electrical cabinet
Three-level water-level control (high/mid/low) prevents dry-burn
Dual pressure control, 0.7MPa working pressure
Full-lift safety valve at 0.73MPa for overpressure relief
Furnace-wall temperature protection: auto cut-off above 165°C + audible-visual alarm
LCD display for heater, water level, pump, pressure and fault status
Outlet DN15 / Inlet DN15 / Blowdown DN20
No boiler-use license required — eliminates compliance paperwork
Stepped group control avoids large-boiler low-load energy waste
CE certified
Fully automatic operation; simple installation — just connect power and water

Applications

Steam supply for pharmaceutical manufacturing processes
Food steaming / sterilisation steam
Chemical reaction vessel heating
Auxiliary steam for small-to-medium production lines

Secteurs

Pharmaceutique
Agroalimentaire et boissons
Chemical
Health & nutraceuticals
Laboratoire

Marques des composants

Air switch (with leakage protection)
Chint
AC contactor
LS
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

CE
Boiler-use license exempt (water capacity <30L)

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→