Sala de exposición en Ontario, California · Consulte el soporte para su destino
SED-60ZQ-J
Consultar
SED-60ZQ-J
SED · SED-60ZQ-J · Destacado

SED-60ZQ-J — Electric Steam Generator

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-60ZQ-J 60kW inspection-exempt electric steam generator. Water capacity below 30L — within the national exemption from boiler-use license. Rated steam output 85kg/h, saturated steam temperature 171°C, rated pressure 0

CEBoiler-use license exempt (water capacity <30L)
Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Water is loaded into the boiler body. Depending on steam demand, one, two or all three 20kW heating element groups are activated. The elements heat the water to produce saturated steam (171°C / 0.7MPa) which is delivered through the DN15 steam outlet. Three-level water-level control (high/mid/low) prevents dry-burn on water stoppage; dual pressure controllers automatically cut power if pressure exceeds the set point; a full-lift safety valve opens at 0.73MPa for additional pressure relief; a wall-temperature sensor cuts power and triggers an alarm if the furnace wall exceeds 165°C.

Proceso de funcionamiento
1Water is loaded into the boiler body.
2Depending on steam demand, one, two or all three 20kW heating element groups are activated.
3The elements heat the water to produce saturated steam (171°C / 0.7MPa) which is delivered through the DN15 steam outlet.
4Three-level water-level control (high/mid/low) prevents dry-burn on water stoppage; dual pressure controllers automatically cut power if pressure exceeds the set point; a full-lift safety valve opens at 0.73MPa for additional pressure relief; a wall-temperature sensor cuts power and triggers an alarm if the furnace wall exceeds 165°C.

Especificaciones técnicas

Especificaciones de la variante: SED-60ZQ-J

Especificaciones

Modelo
SED-60ZQ-J
Tensión
380V 50Hz 3Φ
Potencia
60 kW

Dimensiones

Longitud
790 mm
Anchura
520 mm
Altura
1260 mm

Materiales

Materiales en contacto
316L seamless stainless-steel heating tubes
Materiales del cuerpo
Anti-corrosion-treated boiler body and fittings

Características principales

Boiler-use license exempt (water capacity <30L)
Three independent 20kW heating-tube groups with stepped adjustment
Each group equipped with its own leakage circuit breaker
316L seamless SS heating tubes + imported high-temperature magnesium powder, rated 1000°C
Flange-type assembly for easy tube replacement
Water-electricity separated electrical cabinet
Three-level water-level control (high/mid/low) prevents dry-burn
Dual pressure control, 0.7MPa working pressure
Full-lift safety valve at 0.73MPa for overpressure relief
Furnace-wall temperature protection: auto cut-off above 165°C + audible-visual alarm
LCD display for heater, water level, pump, pressure and fault status
Outlet DN15 / Inlet DN15 / Blowdown DN20
No boiler-use license required — eliminates compliance paperwork
Stepped group control avoids large-boiler low-load energy waste
CE certified
Fully automatic operation; simple installation — just connect power and water

Aplicaciones

Steam supply for pharmaceutical manufacturing processes
Food steaming / sterilisation steam
Chemical reaction vessel heating
Auxiliary steam for small-to-medium production lines

Sectores

Farmacéutico
Alimentación y bebidas
Chemical
Health & nutraceuticals
Laboratorio

Marcas de componentes

Air switch (with leakage protection)
Chint
AC contactor
LS
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

CE
Boiler-use license exempt (water capacity <30L)

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→