Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Chromatographe en phase liquide / High Performance Liquid Chromatograph (HPLC)
SED-600YXSPY-H
Sur devis
SED-600YXSPY-H
SED · SED-600YXSPY-H · En vedette

SED-600YXSPY-H — High Performance Liquid Chromatograph

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-600YXSPY-H High Performance Liquid Chromatograph (HPLC). Integrated design with high-pressure constant flow pump and UV detector optimized for isocratic/gradient analysis. Workstation controls multiple pumps, UV dete

Choisir une variante (3)
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Sample enters via 7725i manual injection valve into the dual-plunger reciprocating parallel high-pressure constant flow pump system; after mixing through the gradient mixer, it is separated on a C18 column (250mm×4.6mm, 5μm). Column oven controls temperature (RT+5°C~80°C). Separated components are detected in the parallel dual-cone-hole flow cell UV detector (8μL cell volume). Full digital signal is transmitted to the chromatography workstation for data processing and quantification.

Processus de fonctionnement
1Sample enters via 7725i manual injection valve into the dual-plunger reciprocating parallel high-pressure constant flow pump system; after mixing through the gradient mixer, it is separated on a C18 column (250mm×4.6mm, 5μm).
2Column oven controls temperature (RT+5°C~80°C).
3Separated components are detected in the parallel dual-cone-hole flow cell UV detector (8μL cell volume).
4Full digital signal is transmitted to the chromatography workstation for data processing and quantification.

Caractéristiques techniques

Caractéristiques de la variante : SED-600YXSPY-H intelligent fully-controlled gradient configuration (dual P2600 binary high-pressure pumps)

Caractéristiques

Modèle
SED-600YXSPY-H
Tension
220V 50Hz 1Φ

Caractéristiques principales

High-pressure pump up to 42MPa, flow 0.001~9.999mL/min (RSD<0.06%)
Reciprocating parallel dual-plunger pump design, pressure pulsation 0.1 MPa
Diaphragm-type surge damper + electronic pulsation suppression
Integral check valve, simple structure, good sealing
Automatic plunger retraction for easy seal replacement
Optional post-column wash (for buffer salt analyses)
Parallel dual-cone-hole flow cell for high SNR
Power-on self-test + full digital switching system
Wavelength precision <0.1nm, accuracy ±1nm
Min detection concentration 5×10⁻⁹ g/mL
Six quantification methods in chromatography workstation
Remote control and monitoring of all units
Full Chinese interface (English optional)
Column oven RT+5°C~80°C, temperature precision ±0.1°C
Qualitative repeatability RSD≤0.1% (n=6)
Quantitative repeatability RSD≤0.2% (n=6)
Intelligent fully-controlled gradient configuration (dual P2600 binary high-pressure pumps)
Gradient + intelligent dual model options
Workstation with dual functions: LC system control + chromatography data processing
Optional detectors: RI, fluorescence, DAD, ELSD
Multi-point concentration calibration curves with sample concentration-area correction

Applications

High performance liquid chromatography analysis
Isocratic analysis
Gradient analysis
Pharmaceutical analysis
Chemical component content determination
Wavelength scanning

Secteurs

Pharmaceutique
Chemical
Food
Environmental testing
Research institutes

Marques des composants

High-pressure pump
P2600 binary
UV detector
UV2600 (190~700nm)
Manual injection valve
7725i
Chromatography column
C18 250mm×4.6mm 5μm
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→