SED-600YXSPY-H High Performance Liquid Chromatograph (HPLC). Integrated design with high-pressure constant flow pump and UV detector optimized for isocratic/gradient analysis. Workstation controls multiple pumps, UV dete

Elegir variante (3)
Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Sample enters via 7725i manual injection valve into the dual-plunger reciprocating parallel high-pressure constant flow pump system; after mixing through the gradient mixer, it is separated on a C18 column (250mm×4.6mm, 5μm). Column oven controls temperature (RT+5°C~80°C). Separated components are detected in the parallel dual-cone-hole flow cell UV detector (8μL cell volume). Full digital signal is transmitted to the chromatography workstation for data processing and quantification.

Proceso de funcionamiento
1Sample enters via 7725i manual injection valve into the dual-plunger reciprocating parallel high-pressure constant flow pump system; after mixing through the gradient mixer, it is separated on a C18 column (250mm×4.6mm, 5μm).
2Column oven controls temperature (RT+5°C~80°C).
3Separated components are detected in the parallel dual-cone-hole flow cell UV detector (8μL cell volume).
4Full digital signal is transmitted to the chromatography workstation for data processing and quantification.

Especificaciones técnicas

Especificaciones de la variante: SED-600YXSPY-H intelligent fully-controlled gradient configuration (dual P2600 binary high-pressure pumps)

Especificaciones

Modelo
SED-600YXSPY-H
Tensión
220V 50Hz 1Φ

Características principales

High-pressure pump up to 42MPa, flow 0.001~9.999mL/min (RSD<0.06%)
Reciprocating parallel dual-plunger pump design, pressure pulsation 0.1 MPa
Diaphragm-type surge damper + electronic pulsation suppression
Integral check valve, simple structure, good sealing
Automatic plunger retraction for easy seal replacement
Optional post-column wash (for buffer salt analyses)
Parallel dual-cone-hole flow cell for high SNR
Power-on self-test + full digital switching system
Wavelength precision <0.1nm, accuracy ±1nm
Min detection concentration 5×10⁻⁹ g/mL
Six quantification methods in chromatography workstation
Remote control and monitoring of all units
Full Chinese interface (English optional)
Column oven RT+5°C~80°C, temperature precision ±0.1°C
Qualitative repeatability RSD≤0.1% (n=6)
Quantitative repeatability RSD≤0.2% (n=6)
Intelligent fully-controlled gradient configuration (dual P2600 binary high-pressure pumps)
Gradient + intelligent dual model options
Workstation with dual functions: LC system control + chromatography data processing
Optional detectors: RI, fluorescence, DAD, ELSD
Multi-point concentration calibration curves with sample concentration-area correction

Aplicaciones

High performance liquid chromatography analysis
Isocratic analysis
Gradient analysis
Pharmaceutical analysis
Chemical component content determination
Wavelength scanning

Sectores

Farmacéutico
Chemical
Food
Environmental testing
Research institutes

Marcas de componentes

High-pressure pump
P2600 binary
UV detector
UV2600 (190~700nm)
Manual injection valve
7725i
Chromatography column
C18 250mm×4.6mm 5μm
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→