Accueil / Équipements / Transformateur triphasé de type sec / Three-Phase Isolation Transformer (Y/Y, 30 kVA)
SED-30SGB-C
Sur devis
SED-30SGB-C
SED · SED-30SGB-C · En vedette
SED-30SGB-C — Three-Phase Isolation Transformer
La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English
SED-30SGB-C 30 kVA Three-phase Isolation Transformer (Y/Y connection). Steps 480V three-phase down to 220V three-phase with neutral and PE. Rated current 78.7 A. Short-circuit impedance 4%, no-load current <=3%, output a
Délai de livraison
Sur devis
Cadence
Contactez-nous
Fonctionnement
Y/Y-connected three-phase isolation transformer with primary winding for 480V and secondary winding for 220V N PE. Magnetic isolation between input and output blocks DC, common-mode noise, and ground-loop currents. Class H insulation handles coil temperatures up to 155 deg C; dry-type air-cooling via cabinet ventilation louvers.
Processus de fonctionnement
1Y/Y-connected three-phase isolation transformer with primary winding for 480V and secondary winding for 220V N PE.
2Magnetic isolation between input and output blocks DC, common-mode noise, and ground-loop currents.
3Class H insulation handles coil temperatures up to 155 deg C; dry-type air-cooling via cabinet ventilation louvers.
Caractéristiques techniques
Caractéristiques de la variante : SED-30SGB-C
Caractéristiques
Modèle
SED-30SGB-C
Tension
Input 480V 3P; Output 220V N PE 3P; rated current 78.7A; 50/60Hz
Détails de conformité
Compliant with VDE0550, IEC439, JB5555, GB226 standards. Insulation resistance test instrument ZC25B-4 megohmmeter @ 1000V. Dielectric strength test instrument VG2670A withstand-voltage tester @ 20 mA.
Dimensions
Longueur
580 mm
Largeur
420 mm
Hauteur
630 mm
Poids
140 kg
Caractéristiques principales
Three-phase isolation transformer, Y/Y connection
Capacity 30 kVA
Input 480V 3P; output 220V N PE 3P
Rated current 78.7 A; short-circuit impedance 4%; no-load current <=3%
Output accuracy +/-1%; voltage regulation <=1.5%; no waveform distortion
Class H insulation, coil insulation temp 155 deg C
Efficiency >=98%
1.2x rated load for 4 hours overload capability
Noise <=35 dB at 1 m; temperature rise <=60 deg C
Insulation resistance >=150 MOhm (measured >=50 MOhm at 1000V Megohmmeter)
Dielectric strength 3000 VAC / 1 min
Design life 20 years
Dry-type air-cooled
White metal cabinet with power meter, indicator lamps, ventilation louvers, casters
Internal three-column winding (A/B/C phase)
Galvanic isolation: protects sensitive equipment from upstream noise and ground loops
Compliant with VDE0550, IEC439, JB5555, GB226 standards
Industrial-grade construction with 20-year design life
Applications
Voltage matching of 480V mains to 220V three-phase loads
Galvanic isolation for sensitive electronics or instrumentation
Imported-equipment power conditioning (480/220V regions)
GMP plant utility transformer
Secteurs
Pharmaceutical / GMP plant utilities
Industrial machinery
Imported equipment installation
Power distribution
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe
Conformité
VDE0550
IEC439
JB5555
GB226
Documentation
Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial