SED-30SGB-C 30 kVA Three-phase Isolation Transformer (Y/Y connection). Steps 480V three-phase down to 220V three-phase with neutral and PE. Rated current 78.7 A. Short-circuit impedance 4%, no-load current <=3%, output a

VDE0550IEC439JB5555GB226
Lieferzeit
Auf Anfrage
Durchsatz
Kontaktieren Sie uns

Funktionsweise

Y/Y-connected three-phase isolation transformer with primary winding for 480V and secondary winding for 220V N PE. Magnetic isolation between input and output blocks DC, common-mode noise, and ground-loop currents. Class H insulation handles coil temperatures up to 155 deg C; dry-type air-cooling via cabinet ventilation louvers.

Prozessbeschreibung
1Y/Y-connected three-phase isolation transformer with primary winding for 480V and secondary winding for 220V N PE.
2Magnetic isolation between input and output blocks DC, common-mode noise, and ground-loop currents.
3Class H insulation handles coil temperatures up to 155 deg C; dry-type air-cooling via cabinet ventilation louvers.

Technische Daten

Technische Daten für Variante: SED-30SGB-C

Technische Daten

Modell
SED-30SGB-C
Spannung
Input 480V 3P; Output 220V N PE 3P; rated current 78.7A; 50/60Hz
Konformitätsangaben
Compliant with VDE0550, IEC439, JB5555, GB226 standards. Insulation resistance test instrument ZC25B-4 megohmmeter @ 1000V. Dielectric strength test instrument VG2670A withstand-voltage tester @ 20 mA.

Abmessungen

Länge
580 mm
Breite
420 mm
Höhe
630 mm
Gewicht
140 kg

Wesentliche Merkmale

Three-phase isolation transformer, Y/Y connection
Capacity 30 kVA
Input 480V 3P; output 220V N PE 3P
Rated current 78.7 A; short-circuit impedance 4%; no-load current <=3%
Output accuracy +/-1%; voltage regulation <=1.5%; no waveform distortion
Class H insulation, coil insulation temp 155 deg C
Efficiency >=98%
1.2x rated load for 4 hours overload capability
Noise <=35 dB at 1 m; temperature rise <=60 deg C
Insulation resistance >=150 MOhm (measured >=50 MOhm at 1000V Megohmmeter)
Dielectric strength 3000 VAC / 1 min
Design life 20 years
Dry-type air-cooled
White metal cabinet with power meter, indicator lamps, ventilation louvers, casters
Internal three-column winding (A/B/C phase)
Galvanic isolation: protects sensitive equipment from upstream noise and ground loops
Compliant with VDE0550, IEC439, JB5555, GB226 standards
Industrial-grade construction with 20-year design life

Anwendungen

Voltage matching of 480V mains to 220V three-phase loads
Galvanic isolation for sensitive electronics or instrumentation
Imported-equipment power conditioning (480/220V regions)
GMP plant utility transformer

Branchen

Pharmaceutical / GMP plant utilities
Industrial machinery
Imported equipment installation
Power distribution
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

VDE0550
IEC439
JB5555
GB226

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→