Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Générateur de vapeur pure / Pharmaceutical Water Equipment - Pure Steam Generator
SED-240CZQ1-J
Sur devis
SED-240CZQ1-J
SED · SED-240CZQ1-J · En vedette

SED-240CZQ1-J — Pharmaceutical Water Equipment - Pure Steam Generator

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-240CZQ1-J Clean Steam Generator (indirect heat exchange type). Produces 240 kg/h saturated clean steam at 0.5 MPa rated pressure / 158°C. Uses industrial steam (300 kg/h consumption at 0.8–1.0 MPa input). 316L stainl

Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Industrial steam (0.8–1.0 MPa) enters the shell side of three groups of 316L thick-wall seamless heat-exchange coils through a pneumatic high-temp angle valve. Feed water from the NIKUNI 370W pump enters the 316L boiler shell where it is indirectly heated by the coils to produce saturated clean steam at 0.5 MPa / 158°C. The PLC modulates the industrial-steam intake based on demand for low-load efficiency. Boiler water level is monitored by a magnetic float level gauge (SPES, 316L) with 3-level (high/mid/low) interlock to prevent dry-burn. Dual pressure controllers (Danfoss PC10) and a Danfoss KP36 transmitter regulate working pressure and trigger over-pressure shutdown at 0.5 MPa; a 0.55 MPa full-lift safety valve (Guangyi) provides hardware backup. A boiler-wall temperature sensor cuts power if wall temperature exceeds 155°C with audio-visual alarm. Automatic feedwater control, blowdown, and condensate trap maintain steady operation. WIKA pressure gauge displays system pressure.

Processus de fonctionnement
1Industrial steam (0.8–1.0 MPa) enters the shell side of three groups of 316L thick-wall seamless heat-exchange coils through a pneumatic high-temp angle valve.
2Feed water from the NIKUNI 370W pump enters the 316L boiler shell where it is indirectly heated by the coils to produce saturated clean steam at 0.5 MPa / 158°C.
3The PLC modulates the industrial-steam intake based on demand for low-load efficiency.
4Boiler water level is monitored by a magnetic float level gauge (SPES, 316L) with 3-level (high/mid/low) interlock to prevent dry-burn.
5Dual pressure controllers (Danfoss PC10) and a Danfoss KP36 transmitter regulate working pressure and trigger over-pressure shutdown at 0.5 MPa; a 0.55 MPa full-lift safety valve (Guangyi) provides hardware backup.
6A boiler-wall temperature sensor cuts power if wall temperature exceeds 155°C with audio-visual alarm.
7Automatic feedwater control, blowdown, and condensate trap maintain steady operation.
8WIKA pressure gauge displays system pressure.

Caractéristiques techniques

Caractéristiques de la variante : SED-240CZQ1-J

Caractéristiques

Modèle
SED-240CZQ1-J
Tension
220V, 50Hz

Dimensions

Longueur
1450 mm
Largeur
890 mm
Hauteur
1450 mm

Matériaux

Matériaux en contact
316L stainless steel (boiler shell, piping, heat exchange coils, valves); internally polished
Matériaux du bâti
304 stainless steel cabinet; 316L stainless steel boiler shell

Caractéristiques principales

Clean steam output 240 kg/h
Indirect heat exchange via 316L thick-wall seamless coils (×3 groups)
316L boiler shell, piping, valves, and heat exchange coils
Internally polished — pharmaceutical-grade cleanliness
304 stainless steel cabinet
Boiler water volume <30L — license-free in China
PLC + LCD touchscreen control
Auto industrial-steam intake regulation per steam demand
Saturated steam at 0.5 MPa / 158°C
Industrial steam input 0.8–1.0 MPa, ~300 kg/h consumption
3-level water level control (high/mid/low) anti-dry-burn
Dual pressure control with adjustable working pressure
Safety valve 0.55 MPa full-lift
Wall over-temperature cutoff at 155°C with audio-visual alarm
Plug-and-play installation: connect water + power, press start
Real-time LCD display of coil status, water level, pump status, pressure, alarms
Flange-connected coils for easy disassembly/replacement
License-free boiler — saves regulatory burden in China
Auto demand-based steam intake — energy-efficient at low load
NIKUNI Japanese feedwater pump — premium component
Schneider electrical components (leakage protector, contactor)
Danfoss pressure controllers and transmitter
WIKA pressure gauge
15-month warranty (vs typical 12)
25-day delivery; price includes 13% VAT, packaging, freight, and insurance

Applications

Pharmaceutical SIP (steam-in-place) sterilization
Pharmaceutical equipment sterilization
Food / beverage clean steam supply
Cosmetic / chemical clean steam

Secteurs

Pharmaceutique
Biotechnologie
Food processing
Cosmétiques

Marques des composants

PLC + touch screen
Bonpu/
Leakage protector
Schneider
AC contactor + thermal relay
Schneider
Heat exchanger coils (12mm 316L, ×3 groups)
In-house manufacture
Feed water pump (370W)
NIKUNI
Safety valve DN20 (304)
Guangyi/
Steam valve / blowdown / check valve (316L) DN20/15
Kangtai/
Pneumatic high-temp angle valve DN25 / SS trap DN25 (304)
Jingrui/
Pressure controller PC10
Danfoss
Pressure transmitter KP36
Danfoss
Magnetic float level gauge (316L)
SPES
Pressure gauge axial Y60 1.6 MPa
WIKA
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→