Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
SED-2-2XGS-L
Sur devis
SED-2-2XGS-L
SED · SED-2-2XGS-L · En vedette

SED-2-2XGS-L — Liquid Filling and Stoppering Machine

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-2-2XGS-L liquid filling and stoppering machine for sterile pharmaceutical vials. Servo-driven design, configurable with ceramic plunger pumps or peristaltic pumps. Linear or rotary work modes; star-wheel transfer to

cGMPFDAGAMPFederal Standard 209 / EN ISO 14644-1 Class 5 (Class 100 environment)
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Vials enter on a brushless-motor-driven rotary transport system. Two filling nozzles (ceramic plunger or peristaltic pumps, selectable) dose liquid with HMI-stored recipes for speed/height/stroke. A star wheel transfers vials to the stoppering station. A 316L stainless-steel vibratory bowl feeds rubber stoppers to the rotary stopper carousel where vacuum pickup holds each stopper. A lift platform raises each vial to insert the stopper - full or partial insertion selectable. Sensors and interlocks ensure no-vial-no-fill / no-vial-no-stopper and reject defective units.

Processus de fonctionnement
1Vials enter on a brushless-motor-driven rotary transport system.
2Two filling nozzles (ceramic plunger or peristaltic pumps, selectable) dose liquid with HMI-stored recipes for speed/height/stroke.
3A star wheel transfers vials to the stoppering station.
4A 316L stainless-steel vibratory bowl feeds rubber stoppers to the rotary stopper carousel where vacuum pickup holds each stopper.
5A lift platform raises each vial to insert the stopper - full or partial insertion selectable.
6Sensors and interlocks ensure no-vial-no-fill / no-vial-no-stopper and reject defective units.

Caractéristiques techniques

Caractéristiques de la variante : SED-2-2XGS-L

Caractéristiques

Modèle
SED-2-2XGS-L
Tension
380V +/-10%, 50Hz, 3-phase
Puissance
4.5 kW
Pression d’air
4-6 bar

Dimensions

Longueur
2200 mm
Largeur
1580 mm
Hauteur
2600 mm
Poids
1200 kg

Matériaux

Matériaux en contact
AISI 316L stainless steel (stopper vibratory bowl)

Caractéristiques principales

Servo-driven, brushless-motor rotary transport, recipe-managed via HMI
Configurable with ceramic plunger pumps or peristaltic pumps
2-head dosing; filling tolerance <=+/-2%
Star-wheel transfer between filling and stoppering stations
316L stainless-steel vibratory bowl for rubber stoppers
Vacuum-pickup stoppering carousel
Switchable full or half stoppering, completion >=99.8%
Production capacity 60 vials/min (5 ml basis, stable >=15 vpm)
Applicable vial range 2-50 ml (filling), 2-10 ml (stoppering)
Compressed air 4-6 bar, vacuum -6x10^-2 MPa / 25 m3/h
Noise <=75 dB
Safety interlocks on glass doors
Vial-presence sensor at infeed, infeed-screw overload sensor
Stopper-presence control on carousel and on vial
Stopper level monitoring in vibratory bowl
Production statistics via photoelectric counting, automatic rejection
Optional Schneider 15-inch IPC + EMSE audit-trail upgrade
Optional UPS, Petri plate / isokinetic probe / microbiological sampler supports
Optional LAF (laminar-flow hood) over filling machine
Optional validation documentation (DQ/IQ/OQ)
Imported-grade 316L SS stopper vibratory bowl, FDA/cGMP/GAMP-compliant design
Audit-trail-ready when upgraded with Schneider IPC + EMSE
Switchable full/half stoppering supports lyo-line workflows
Modular pump choice (ceramic or peristaltic) for varied product viscosities

Applications

Sterile vial filling and stoppering for liquid injectables
Lyo line stoppering (half-stopper mode)
Vials 2-50 ml (filling), 2-10 ml (stoppering)
Standard 5 ml or 10 ml vials

Secteurs

Pharmaceutical injectables
Sterile fill-finish
Biopharma
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

cGMP
FDA
GAMP
Federal Standard 209 / EN ISO 14644-1 Class 5 (Class 100 environment)

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→