Horizontal pulsed-vacuum steam sterilizer (SED-150ZQM-D). Uses saturated steam to sterilize items. Round chamber, self-contained steam generator with external steam option, single door, jacketed design, main material sta

Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Pulsed-vacuum steam sterilization: 3+ vacuum pulses to evacuate air from packaged, unpackaged, hollow, porous, and internally-piped instruments. Sterilization at 105-134°C with steam pressure 0.05-0.22 MPa (microcomputer-controlled). Includes timed sterilization (0-99 min) and deep drying (0-99 min). Multi-stage safety: door interlock prevents opening when chamber pressure >0.027 MPa, safety valve over-pressure relief, low-water cutoff, over-current breaker. Bowie & Dick test function for steam penetration verification. Printer logs full cycle.

Processus de fonctionnement
1Pulsed-vacuum steam sterilization: 3+ vacuum pulses to evacuate air from packaged, unpackaged, hollow, porous, and internally-piped instruments.
2Sterilization at 105-134°C with steam pressure 0.05-0.22 MPa (microcomputer-controlled).
3Includes timed sterilization (0-99 min) and deep drying (0-99 min).
4Multi-stage safety: door interlock prevents opening when chamber pressure >0.027 MPa, safety valve over-pressure relief, low-water cutoff, over-current breaker.
5Bowie & Dick test function for steam penetration verification.
6Printer logs full cycle.

Caractéristiques techniques

Caractéristiques de la variante : SED-150ZQM-D

Caractéristiques

Modèle
SED-150ZQM-D
Tension
AC380V 50Hz
Fluides et énergie
9 kW / AC380V 50Hz; water supply for steam generator; steam supply if using external mode; drain connection
Détails de conformité
Pressure-vessel sterilizer with safety interlocks: door cannot open when chamber pressure >0.027 MPa; safety valve relieves over-pressure; low-water and over-current protection.
Puissance
9 kW

Dimensions

Longueur
1400 mm
Largeur
650 mm
Hauteur
1600 mm
Poids
340 kg
Emprise au sol
Equipment dimensions 1400 × 650 × 1600 mm (L×W×H); transport dimensions 1560 × 820 × 1820 mm; net weight 340 kg / gross 430 kg

Matériaux

Matériaux en contact
acier inoxydable
Matériaux du bâti
acier inoxydable; carbon steel option for outer shell

Caractéristiques principales

Capacity 150L (Φ440 × 1000 mm)
Design temperature 150°C / pressure 0.3 MPa
Rated working: 134°C / 0.22 MPa
Temperature range 105-134°C, thermal uniformity ≤±2°C
Vacuum limit -0.08 MPa with 3+ pulse pre-vacuum
Sterilization timer 0-99 min, drying timer 0-99 min
Microcomputer automatic control (no monitoring needed)
Deep drying function for sterilized items
Built-in printer logs full sterilization cycle
Bowie & Dick test function for steam penetration
Auto fault detection
Self-contained steam generator + external steam option
Jacketed single-door design
Weight 340 kg, dimensions 1400 × 650 × 1600 mm
Pulsed vacuum suits packaged, unpackaged, hollow, porous, and internally-piped instruments
Comprehensive safety: over-pressure, over-temperature, auto pressure stabilization, low-water, over-current, door interlock at 0.027 MPa
Steam pressure control 0.05-0.22 MPa with corresponding 110-134°C temperatures, selectable on control panel
Premium stainless steel sterilization chamber
Automatic discharge of air and condensate balances chamber temperature

Applications

Sterilization of medical instruments
Sterilization of dressings
Sterilization of glassware
Sterilization of solution culture media
Sterilization of packaged, unpackaged, hollow, porous, and internally-piped devices

Secteurs

Healthcare facilities
Hospitals
Laboratories
Pharmaceutique
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→