Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Esterilizador a vapor / Horizontal Pulsed-Vacuum Steam Sterilizer
SED-150ZQM-D
Consultar
SED-150ZQM-D
SED · SED-150ZQM-D · Destacado

SED-150ZQM-D — Horizontal Pulsed-Vacuum Steam Sterilizer

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

Horizontal pulsed-vacuum steam sterilizer (SED-150ZQM-D). Uses saturated steam to sterilize items. Round chamber, self-contained steam generator with external steam option, single door, jacketed design, main material sta

Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Pulsed-vacuum steam sterilization: 3+ vacuum pulses to evacuate air from packaged, unpackaged, hollow, porous, and internally-piped instruments. Sterilization at 105-134°C with steam pressure 0.05-0.22 MPa (microcomputer-controlled). Includes timed sterilization (0-99 min) and deep drying (0-99 min). Multi-stage safety: door interlock prevents opening when chamber pressure >0.027 MPa, safety valve over-pressure relief, low-water cutoff, over-current breaker. Bowie & Dick test function for steam penetration verification. Printer logs full cycle.

Proceso de funcionamiento
1Pulsed-vacuum steam sterilization: 3+ vacuum pulses to evacuate air from packaged, unpackaged, hollow, porous, and internally-piped instruments.
2Sterilization at 105-134°C with steam pressure 0.05-0.22 MPa (microcomputer-controlled).
3Includes timed sterilization (0-99 min) and deep drying (0-99 min).
4Multi-stage safety: door interlock prevents opening when chamber pressure >0.027 MPa, safety valve over-pressure relief, low-water cutoff, over-current breaker.
5Bowie & Dick test function for steam penetration verification.
6Printer logs full cycle.

Especificaciones técnicas

Especificaciones de la variante: SED-150ZQM-D

Especificaciones

Modelo
SED-150ZQM-D
Tensión
AC380V 50Hz
Suministros
9 kW / AC380V 50Hz; water supply for steam generator; steam supply if using external mode; drain connection
Detalles de conformidad
Pressure-vessel sterilizer with safety interlocks: door cannot open when chamber pressure >0.027 MPa; safety valve relieves over-pressure; low-water and over-current protection.
Potencia
9 kW

Dimensiones

Longitud
1400 mm
Anchura
650 mm
Altura
1600 mm
Peso
340 kg
Superficie de instalación
Equipment dimensions 1400 × 650 × 1600 mm (L×W×H); transport dimensions 1560 × 820 × 1820 mm; net weight 340 kg / gross 430 kg

Materiales

Materiales en contacto
acero inoxidable
Materiales del cuerpo
acero inoxidable; carbon steel option for outer shell

Características principales

Capacity 150L (Φ440 × 1000 mm)
Design temperature 150°C / pressure 0.3 MPa
Rated working: 134°C / 0.22 MPa
Temperature range 105-134°C, thermal uniformity ≤±2°C
Vacuum limit -0.08 MPa with 3+ pulse pre-vacuum
Sterilization timer 0-99 min, drying timer 0-99 min
Microcomputer automatic control (no monitoring needed)
Deep drying function for sterilized items
Built-in printer logs full sterilization cycle
Bowie & Dick test function for steam penetration
Auto fault detection
Self-contained steam generator + external steam option
Jacketed single-door design
Weight 340 kg, dimensions 1400 × 650 × 1600 mm
Pulsed vacuum suits packaged, unpackaged, hollow, porous, and internally-piped instruments
Comprehensive safety: over-pressure, over-temperature, auto pressure stabilization, low-water, over-current, door interlock at 0.027 MPa
Steam pressure control 0.05-0.22 MPa with corresponding 110-134°C temperatures, selectable on control panel
Premium stainless steel sterilization chamber
Automatic discharge of air and condensate balances chamber temperature

Aplicaciones

Sterilization of medical instruments
Sterilization of dressings
Sterilization of glassware
Sterilization of solution culture media
Sterilization of packaged, unpackaged, hollow, porous, and internally-piped devices

Sectores

Healthcare facilities
Hospitals
Laboratories
Farmacéutico
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→