Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Secador túnel por microondas / Tunnel Microwave Dryer / Sterilizer
SED-27SDW-C
Consultar
SED-27SDW-C
SED · SED-27SDW-C · Destacado

SED-27SDW-C — Tunnel Microwave Dryer / Sterilizer

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

Tunnel-type microwave dryer/sterilizer (3 microwave chambers) for continuous drying or sterilization of solid pharmaceutical and food materials. Microwave frequency 2450 ± 50 MHz, total microwave equipment power 29.5 kW

GB10436-89 (microwave leakage standard)GB16798-1997 (food machinery hygiene safety)GB5226 (electrical safety)
Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Material is conveyed continuously on a 600 mm wide PTFE/Teflon belt through three microwave chambers. Top-fed standard rectangular waveguide ports deliver 2450 MHz microwave energy from Panasonic 2M244-M1J1 magnetrons. The microwaves cause polar molecules (primarily water) inside the material to oscillate and self-heat, simultaneously drying and (above ~80°C) sterilizing the load. A German Optris infrared sensor reads the surface temperature (0-300°C, ±0.1°C) and PLC adjusts microwave output power and belt speed to hold the setpoint. A bottom-in / top-out airflow path collects the evolved water vapor, which is exhausted through PVC ducting by a 0.75 kW centrifugal fan at 1200 m³/min. Dual inductive-comb suppressors at the belt entry/exit prevent microwave leakage.

Proceso de funcionamiento
1Material is conveyed continuously on a 600 mm wide PTFE/Teflon belt through three microwave chambers.
2Top-fed standard rectangular waveguide ports deliver 2450 MHz microwave energy from Panasonic 2M244-M1J1 magnetrons.
3The microwaves cause polar molecules (primarily water) inside the material to oscillate and self-heat, simultaneously drying and (above ~80°C) sterilizing the load.
4A German Optris infrared sensor reads the surface temperature (0-300°C, ±0.1°C) and PLC adjusts microwave output power and belt speed to hold the setpoint.
5A bottom-in / top-out airflow path collects the evolved water vapor, which is exhausted through PVC ducting by a 0.75 kW centrifugal fan at 1200 m³/min.
6Dual inductive-comb suppressors at the belt entry/exit prevent microwave leakage.

Especificaciones técnicas

Especificaciones de la variante: SED-27SDW-C

Especificaciones

Modelo
SED-27SDW-C
Tensión
3-phase 5-wire 380V±10% 50Hz
Suministros
Power: 3-phase 5-wire 380V±10% 50Hz, total 29.5 kW. Operating environment: no corrosive gas, conductive dust or explosive gas; temperature -5 to 45°C; relative humidity ≤80%.
Potencia
29.5 kW

Dimensiones

Longitud
6400 mm
Anchura
1400 mm
Altura
1600 mm
Superficie de instalación
Frame: 6400 × 1400 × 1600 mm (L×W×H). Microwave cavity: 3600 × 700 × 500 mm. Side discharge outlet at 365 mm height.

Materiales

Materiales en contacto
PTFE Teflon belt (rated 350°C); SUS304 (3 mm thick) inner cavity
Materiales del cuerpo
Stainless steel square tube frame; SUS304 panels (δ1.2 mm outer, δ1.5 mm working chamber) from POSCO Korean Zhangpu

Características principales

Tunnel design with 3 microwave chambers
Microwave frequency 2450 ± 50 MHz, output ≤27 kW segmented adjustable (auto + manual)
Total microwave power 29.5 kW
PTFE Teflon belt rated 350°C, 600 mm wide
Variable frequency belt speed control
Anti-skew guide groove; idler rollers every 0.3 m; belt tension adjustment device
Cavity 3 mm thick stainless steel SUS304 (3.6×0.7×0.5 m); all openings reinforced to 3.0 mm
Stainless steel square tube frame (6.4 × 1.4 × 1.6 m)
Top-fed waveguide; isolation between feed ports >20 dB
Standing wave ratio <2 at rated load
Imported air-cooled Panasonic magnetron + special transformer
Process temperature 60-120°C via PLC + German Optris IR sensor (0-300°C, ±0.1°C)
Auto power adjustment based on temperature setpoint
Magnetron health diagnostics — damage alarm
Bottom-in / top-out moisture exhaust via PVC ducting
Centrifugal fan 0.75 kW, 1200 m³/min, 1120 Pa
Dust filter on magnetron cooling air inlet
Dual inductive-comb leakage suppressors (800 mm × 2) + absorber material
Microwave leakage <5 mW/cm² at 5 cm (GB10436-89)
Door interlock — microwave off when door not fully closed
Side discharge port at 365 mm floor height (connectable to downstream conveyor)
Video monitoring of belt and material
PLC HMI control

Aplicaciones

Continuous drying of solid pharmaceutical materials (granules, powders, coated solids)
Sterilization of pharmaceutical and food raw materials
Drying and sterilization of Chinese herbal medicine

Sectores

Fabricación farmacéutica
Food processing
Traditional Chinese medicine

Marcas de componentes

Outer panels (δ1.2 mm SUS304)
POSCO (Korean Zhangpu)
Working chamber panels (δ1.5 mm)
POSCO (Korean Zhangpu)
Conveyor belt (PTFE, Δ500 mm)
Local supplier
Motor & reducer (WB150)
Tianmai
Front/rear drive rollers (Φ200) and idler rollers (Φ40)
In-house
Exhaust fan (0.75 kW)
Local supplier
Magnetron (2M244-M1J1)
Panasonic
Microwave-specific driver (Wepex 1000B-F)
Megmeet
Far-infrared temperature sensor (0-300°C)
Optris
Frame and reinforcement (stainless square tube)
Nansteel
Video monitoring
Local supplier
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

GB10436-89 (microwave leakage standard)
GB16798-1997 (food machinery hygiene safety)
GB5226 (electrical safety)

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→