Sala de exposición en Ontario, California · Consulte el soporte para su destino
Inicio / Equipos / Armario de esterilización por calor seco / Dry Heat Sterilizer — 0.64 m³, Class 100, Double-Door Electric
SED-0.64GRM-C
Consultar
SED-0.64GRM-C
SED · SED-0.64GRM-C · Destacado

SED-0.64GRM-C — 0.64 m³, Class 100, Double-Door Electric

La descripción completa de este modelo aún se está traduciendo. Consulte los detalles en inglés o solicite información a nuestro equipo. English

SED-0.64GRM-C Dry Heat Sterilizer (Class 100 / ISO 5) — double-door interlocked, electrically operated. Chamber inside 800 × 800 × 1,000 mm (0.64 m³); outside 1,950 × 1,150 × 2,370 mm. All-welded inner chamber SUS316L 2

Class 100 (ISO Class 5) clean conditions via HEPA filtration
Elegir variante (1)
Plazo de entrega
Consultar
Capacidad de producción
Contáctenos

Funcionamiento

Forced-air-circulation dry heat sterilization. Inlet air passes CINO pre + medium efficiency filter, then high-temperature HEPA at chamber inlet. Inside the all-welded SS316L chamber, a 0.75 kW high-temperature circulation fan moves air uniformly across loaded baking trays past 21 kW SS304 electric heaters, raising the chamber to setpoint up to 250°C (design 300°C) — protein and pyrogen are destroyed by sustained high-temperature dry heat. After the hold, the cycle switches to forced-air cooling via auxiliary 560 m³/h fan + HEPA-filtered ambient air. Class 100 (ISO 5) clean conditions are maintained inside the chamber via inlet + outlet HEPA filters at all times. Double motorized doors are interlocked.

Proceso de funcionamiento
1Forced-air-circulation dry heat sterilization.
2Inlet air passes CINO pre + medium efficiency filter, then high-temperature HEPA at chamber inlet.
3Inside the all-welded SS316L chamber, a 0.75 kW high-temperature circulation fan moves air uniformly across loaded baking trays past 21 kW SS304 electric heaters, raising the chamber to setpoint up to 250°C (design 300°C) — protein and pyrogen are destroyed by sustained high-temperature dry heat.
4After the hold, the cycle switches to forced-air cooling via auxiliary 560 m³/h fan + HEPA-filtered ambient air.
5Class 100 (ISO 5) clean conditions are maintained inside the chamber via inlet + outlet HEPA filters at all times.
6Double motorized doors are interlocked.

Especificaciones técnicas

Especificaciones de la variante: SED-0 this model

Especificaciones

Modelo
SED-0.64GRM-C
Suministros
Electricity: 8 kW total system load (21 kW is the heater element rating). No process steam required (electric dry-heat). Cooling: forced air via internal fan + auxiliary 560 m³/h fan — no chiller required.
Detalles de conformidad
Built to deliver Class 100 (ISO 5) clean conditions inside the sterilization chamber via inlet + outlet HEPA filtration. Includes Φ32 mm side temperature validation port for GMP qualification. Forced interlock plus sound/light alarm. All-welded SS316L chamber. Outside surface temperature ≤ room +20°C.
Potencia
8 kW

Dimensiones

Longitud
1950 mm
Anchura
1150 mm
Altura
2370 mm
Superficie de instalación
Outside dimensions 1,950 (W) × 1,150 (D) × 2,370 (H) mm. Pass-through double-door — install in wall between sterile and preparation rooms.

Materiales

Materiales en contacto
SUS316L — chamber inner 2 mm, floor plate 3 mm, air-adjust plate 1.5 mm, inner door plate 4 mm, baking trays 0.8 mm.
Materiales del cuerpo
SUS316L chamber inner shell — SUS304 outer 2 mm — SUS304 outer door plate 1.5 mm — 150 mm aluminum-silicate insulation (Jiangyin) — imported silicone-rubber air seal.

Características principales

Chamber 0.64 m³ (800 × 800 × 1,000 mm)
Double-door interlocked, electrically operated (Runle WPDS60-50 reducer, 0.37 kW × 2)
All-welded SS316L chamber 2 mm; SS304 outer 2 mm; SS316L inner door 4 mm
Class 100 (ISO 5): inlet + outlet HEPA (Sujing Jiangsu, 140 × 140 × 150 mm)
High-temperature HEPA 240 × 240 × 150 mm (Sujing Huatai)
CINO pre + medium-efficiency air filters
21 kW Yangzhong SS304 electric heater; 8 kW total system rating
Working temperature room ~ 250°C; design 300°C; empty heat distribution ±3°C
Forced-air cooling: 0.75 kW Chunyang fan + DF-1.6-I 560 m³/h auxiliary fan
Φ32 mm side temperature validation port
150 mm aluminum-silicate insulation; outside surface ≤ room + 20°C
Class 100 clean dry-heat sterilization with HEPA filtration — depyrogenation grade
Double-door pass-through interlock — clean/dirty side separation
All-welded SS316L chamber — pharmaceutically inert
±3°C empty heat distribution — meets pharma validation requirements
Validation port standard — easy GMP qualification
Premium controls: Fuji temperature controller, Schneider relays, Caldwell USA dP gauge
Outside surface stays cool (≤ room +20°C) — operator safe
Forced-air cooling shortens cycle time

Aplicaciones

Dry-heat sterilization of glassware, metal instruments, and heat-stable items
Depyrogenation of glass vials and ampoules
Sterilization of stoppers, oils, and powders that cannot tolerate moisture
Pharmaceutical Class 100 (ISO 5) clean-area sterilization

Sectores

Fabricación farmacéutica
Injectable preparations
Hospitals and clinical labs
Scientific research
Medical device sterilization

Marcas de componentes

CINO — pre + medium efficiency air filters
Sujing Huatai — high-temperature HEPA (240 × 240 × 150 mm)
Sujing Jiangsu — inlet/outlet HEPA (140 × 140 × 150 mm)
Yangzhong — 21 kW SS304 electric heater
Chunyang Nanjing — 0.75 kW high-temperature circulation fan
Yinniu Taizhou — DF-1.6-I 560 m³/h auxiliary fan
Runle Nanjing — WPDS60-50 0.37 kW × 2 door reducer
Fuji Japan — RXR-9 temperature controller
Jiashang Shanghai — Pt100 temperature sensor
Schneider — AC contactor, RXM4LB2P7/RXM2LB2P7 intermediate relays, thermal overload relay
Caldwell USA — SIERS-2000 differential pressure gauge
Sanli Hangzhou — LAY16 buttons
Zhengtai China — YBLX-19-111 motor threshold switch, LJ18A3-8-J/EZ proximity switch
SED
Hable con SED Sales Team
Especialistas en equipos · contacto por WhatsApp
Consulte el horario y la disponibilidad del equipo

Conformidad

Class 100 (ISO Class 5) clean conditions via HEPA filtration

Limpieza y mantenimiento

All-welded SS316L chamber inner — wipe clean between cycles. SS316L baking trays removable for cleaning. Imported silicone rubber door air seal — wipe clean; replace per maintenance schedule.

Documentación

Ficha técnica (PDF)
Resumen del equipo, especificaciones y dimensiones · Documento original (inglés)
Solicitar al equipo comercial
Manual del operador
Instalación, funcionamiento y diagnóstico · Documento original (inglés)
Solicitar al equipo comercial
Ficha comparativa (Estándar y Económica)
Comparación de configuraciones · Documento original (inglés)
Solicitar al equipo comercial
Protocolos IQ / OQ / PQ
Documentación de validación para conformidad GMP · Documento original (inglés)
Solicitar al equipo comercial
Protocolos FAT / SAT
Pruebas de aceptación en fábrica y en sitio · Documento original (inglés)
Solicitar al equipo comercial
Planos CAD (STEP / IGES / DWG)
Planos de ingeniería para la instalación · Documento original (inglés)
Solicitar al equipo comercial
Certificados de calibración
Nivel sonoro, resistencia de tierra, rigidez dieléctrica y rugosidad · Documento original (inglés)
Solicitar al equipo comercial
DQ (cualificación del diseño)
Protocolo completo de cualificación del diseño · Documento original (inglés)
Solicitar al equipo comercial
Certificados de materiales
Composición del acero inoxidable 316L · Documento original (inglés)
Solicitar al equipo comercial
SED
WhatsApp · Ventas SED
Contacto comercial · WhatsApp
→