Startseite / Maschinen / Heißluft-Sterilisationsschrank / Dry Heat Sterilizer — 0.64 m³, Class 100, Double-Door Electric
SED-0.64GRM-C
Auf Anfrage
SED-0.64GRM-C
SED · SED-0.64GRM-C · Hervorgehoben

SED-0.64GRM-C — 0.64 m³, Class 100, Double-Door Electric

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-0.64GRM-C Dry Heat Sterilizer (Class 100 / ISO 5) — double-door interlocked, electrically operated. Chamber inside 800 × 800 × 1,000 mm (0.64 m³); outside 1,950 × 1,150 × 2,370 mm. All-welded inner chamber SUS316L 2

Class 100 (ISO Class 5) clean conditions via HEPA filtration
Variante wählen (1)
Lieferzeit
Auf Anfrage
Durchsatz
Kontaktieren Sie uns

Funktionsweise

Forced-air-circulation dry heat sterilization. Inlet air passes CINO pre + medium efficiency filter, then high-temperature HEPA at chamber inlet. Inside the all-welded SS316L chamber, a 0.75 kW high-temperature circulation fan moves air uniformly across loaded baking trays past 21 kW SS304 electric heaters, raising the chamber to setpoint up to 250°C (design 300°C) — protein and pyrogen are destroyed by sustained high-temperature dry heat. After the hold, the cycle switches to forced-air cooling via auxiliary 560 m³/h fan + HEPA-filtered ambient air. Class 100 (ISO 5) clean conditions are maintained inside the chamber via inlet + outlet HEPA filters at all times. Double motorized doors are interlocked.

Prozessbeschreibung
1Forced-air-circulation dry heat sterilization.
2Inlet air passes CINO pre + medium efficiency filter, then high-temperature HEPA at chamber inlet.
3Inside the all-welded SS316L chamber, a 0.75 kW high-temperature circulation fan moves air uniformly across loaded baking trays past 21 kW SS304 electric heaters, raising the chamber to setpoint up to 250°C (design 300°C) — protein and pyrogen are destroyed by sustained high-temperature dry heat.
4After the hold, the cycle switches to forced-air cooling via auxiliary 560 m³/h fan + HEPA-filtered ambient air.
5Class 100 (ISO 5) clean conditions are maintained inside the chamber via inlet + outlet HEPA filters at all times.
6Double motorized doors are interlocked.

Technische Daten

Technische Daten für Variante: SED-0 this model

Technische Daten

Modell
SED-0.64GRM-C
Versorgung
Electricity: 8 kW total system load (21 kW is the heater element rating). No process steam required (electric dry-heat). Cooling: forced air via internal fan + auxiliary 560 m³/h fan — no chiller required.
Konformitätsangaben
Built to deliver Class 100 (ISO 5) clean conditions inside the sterilization chamber via inlet + outlet HEPA filtration. Includes Φ32 mm side temperature validation port for GMP qualification. Forced interlock plus sound/light alarm. All-welded SS316L chamber. Outside surface temperature ≤ room +20°C.
Leistung
8 kW

Abmessungen

Länge
1950 mm
Breite
1150 mm
Höhe
2370 mm
Aufstellfläche
Outside dimensions 1,950 (W) × 1,150 (D) × 2,370 (H) mm. Pass-through double-door — install in wall between sterile and preparation rooms.

Werkstoffe

Kontaktwerkstoffe
SUS316L — chamber inner 2 mm, floor plate 3 mm, air-adjust plate 1.5 mm, inner door plate 4 mm, baking trays 0.8 mm.
Gehäusewerkstoffe
SUS316L chamber inner shell — SUS304 outer 2 mm — SUS304 outer door plate 1.5 mm — 150 mm aluminum-silicate insulation (Jiangyin) — imported silicone-rubber air seal.

Wesentliche Merkmale

Chamber 0.64 m³ (800 × 800 × 1,000 mm)
Double-door interlocked, electrically operated (Runle WPDS60-50 reducer, 0.37 kW × 2)
All-welded SS316L chamber 2 mm; SS304 outer 2 mm; SS316L inner door 4 mm
Class 100 (ISO 5): inlet + outlet HEPA (Sujing Jiangsu, 140 × 140 × 150 mm)
High-temperature HEPA 240 × 240 × 150 mm (Sujing Huatai)
CINO pre + medium-efficiency air filters
21 kW Yangzhong SS304 electric heater; 8 kW total system rating
Working temperature room ~ 250°C; design 300°C; empty heat distribution ±3°C
Forced-air cooling: 0.75 kW Chunyang fan + DF-1.6-I 560 m³/h auxiliary fan
Φ32 mm side temperature validation port
150 mm aluminum-silicate insulation; outside surface ≤ room + 20°C
Class 100 clean dry-heat sterilization with HEPA filtration — depyrogenation grade
Double-door pass-through interlock — clean/dirty side separation
All-welded SS316L chamber — pharmaceutically inert
±3°C empty heat distribution — meets pharma validation requirements
Validation port standard — easy GMP qualification
Premium controls: Fuji temperature controller, Schneider relays, Caldwell USA dP gauge
Outside surface stays cool (≤ room +20°C) — operator safe
Forced-air cooling shortens cycle time

Anwendungen

Dry-heat sterilization of glassware, metal instruments, and heat-stable items
Depyrogenation of glass vials and ampoules
Sterilization of stoppers, oils, and powders that cannot tolerate moisture
Pharmaceutical Class 100 (ISO 5) clean-area sterilization

Branchen

Pharmazeutische Herstellung
Injectable preparations
Hospitals and clinical labs
Scientific research
Medical device sterilization

Komponentenhersteller

CINO — pre + medium efficiency air filters
Sujing Huatai — high-temperature HEPA (240 × 240 × 150 mm)
Sujing Jiangsu — inlet/outlet HEPA (140 × 140 × 150 mm)
Yangzhong — 21 kW SS304 electric heater
Chunyang Nanjing — 0.75 kW high-temperature circulation fan
Yinniu Taizhou — DF-1.6-I 560 m³/h auxiliary fan
Runle Nanjing — WPDS60-50 0.37 kW × 2 door reducer
Fuji Japan — RXR-9 temperature controller
Jiashang Shanghai — Pt100 temperature sensor
Schneider — AC contactor, RXM4LB2P7/RXM2LB2P7 intermediate relays, thermal overload relay
Caldwell USA — SIERS-2000 differential pressure gauge
Sanli Hangzhou — LAY16 buttons
Zhengtai China — YBLX-19-111 motor threshold switch, LJ18A3-8-J/EZ proximity switch
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

Class 100 (ISO Class 5) clean conditions via HEPA filtration

Reinigung und Wartung

All-welded SS316L chamber inner — wipe clean between cycles. SS316L baking trays removable for cleaning. Imported silicone rubber door air seal — wipe clean; replace per maintenance schedule.

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen