SED-60GZ-H Dry Granulator. Uses crystal water in the material to directly compact powder into granules — eliminates need for liquid binder or secondary drying. Capacity 20-60 kg/h, granule size 0.5-2 mm. Roller Ø200×80 m

Variante wählen (5)
Lieferzeit
Auf Anfrage
Durchsatz
20–60 kg/h

Funktionsweise

Powder is fed via electromagnetic-speed-regulated downward feeder into the compaction zone where two counter-rotating rollers (Ø200×80 mm) compress it into flakes using 10×2 T (≈20 kN) of force, leveraging the material's crystal water as binder. The hydraulic system runs at up to 20 MPa working pressure. Roller cooling water circulation (water temp 20-45 °C, tap water acceptable) prevents sticky-roll and protects heat-sensitive materials. Compacted flakes are then crushed through a sieve by the granulating motor to produce 0.5-2 mm granules.

Prozessbeschreibung
1Powder is fed via electromagnetic-speed-regulated downward feeder into the compaction zone where two counter-rotating rollers (Ø200×80 mm) compress it into flakes using 10×2 T (≈20 kN) of force, leveraging the material's crystal water as binder.
2The hydraulic system runs at up to 20 MPa working pressure.
3Roller cooling water circulation (water temp 20-45 °C, tap water acceptable) prevents sticky-roll and protects heat-sensitive materials.
4Compacted flakes are then crushed through a sieve by the granulating motor to produce 0.5-2 mm granules.

Technische Daten

Technische Daten für Variante: SED-10GZ-H (2-10 kg/h

Technische Daten

Modell
SED-60GZ-H
Durchsatz
20–60 kg/h
Spannung
380V 50Hz 3Φ
Versorgung
380V 50Hz 3-phase power; roller cooling water (20-45 °C, tap water acceptable)
Konformitätsangaben
Sealed operation meets pharmaceutical hygiene requirements. Warranty 12 months from installation, no more than 16 months after delivery.
Leistung
6.95 kW

Werkstoffe

Kontaktwerkstoffe
0Cr26Ni2Mo5 (rollers); 2Cr13Y (roll shafts, conditioned)
Gehäusewerkstoffe
Stainless steel 304 (frame); ZG45 steel (gears, guide rails)

Wesentliche Merkmale

Dry granulation — no water, ethanol, or other wetting agent required
Roller size Ø200×80 mm, max compaction pressure 10×2 T
Roller speed 2-20 rpm, feeding speed 6-60 rpm — both adjustable
Electromagnetic / variable-frequency speed regulation
Roller cooling water circulation prevents sticky-roll
Hydraulic working pressure up to 20 MPa
Sealed operation meeting pharmaceutical hygiene standards
Stainless steel 304 frame
No secondary heating/drying required
Solves granulation for materials that cannot be wet-granulated
Uniform granule density, good disintegration, high yield
Lower cost — fewer process steps, no drying step
Cooling system protects heat-sensitive APIs
Anti-explosion motor option available for dusty environments

Anwendungen

Pharmaceutical pellet/capsule-fill granules
Tablet pre-compression granulation
Food seasoning and manufacturing particles
Plastic molding particles
Catalysts, pigments, and detergents in chemicals

Branchen

Pharma
Food
Chemical
Plastic

Komponentenhersteller

Press/roll motor (4 kW electromagnetic speed regulating) — Market
Tablet reducer BW220 i=29 — Market
Feeding motor (1.1 kW electromagnetic speed regulating) — Market
Feeding reducer BL180 i=29 — Market
Granulation motor (1.1 kW promise-speed) — Market
Hydraulic station (customized 20T, 0.75 kW oil pump) — Market
Jack lifting 5T — Market
Electrical components — Delixi
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Reinigung und Wartung

Disassemble and inspect after each shift. Clean and change lubricant oil/grease every 6 months. Full overhaul every 3 years. Do NOT use metal tools to scrape material from press rollers — maintain scraper-to-roller gap at 0.1 mm.

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→