Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
Startseite / Maschinen / Hochdruckhomogenisator / High-Pressure Homogenizer
SED-60GJZ-C
Auf Anfrage
SED-60GJZ-C High-Pressure Homogenizer
SED · SED-60GJZ-C · 1 verkaufte Einheiten

SED-60GJZ-C — High-Pressure Homogenizer

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-60GJZ-C Laboratory High-Pressure Homogenizer. Single-plunger lab/pilot-series homogenizer for emulsions, dispersions and cell disruption. Pressure to 70 MPa (700 bar) interval / 56 MPa continual; 60 L/h rated flow; p

Lieferzeit
Auf Anfrage
Durchsatz
60 L/h

Funktionsweise

Pre-mixed product is drawn from the feed hopper through the three-joint valve into the pump cylinder by a single reciprocating plunger that pressurizes it to 56-70 MPa. The high-pressure stream then forces through an adjustable two-stage homogenizing valve (high then low pressure). Across the valve, sudden pressure drop, expansion, explosion, shear and high-speed impact subdivide droplets and particles to 0.01-2 µm (avg 1 µm), creating a stable emulsion or dispersion (or rupturing cells for biotech use). Recommended low-stage = 20% of high-stage for best dispersion and longer wear-part life.

Prozessbeschreibung
1Pre-mixed product is drawn from the feed hopper through the three-joint valve into the pump cylinder by a single reciprocating plunger that pressurizes it to 56-70 MPa.
2The high-pressure stream then forces through an adjustable two-stage homogenizing valve (high then low pressure).
3Across the valve, sudden pressure drop, expansion, explosion, shear and high-speed impact subdivide droplets and particles to 0.01-2 µm (avg 1 µm), creating a stable emulsion or dispersion (or rupturing cells for biotech use).
4Recommended low-stage = 20% of high-stage for best dispersion and longer wear-part life.

Technische Daten

Technische Daten für Variante: SED-60GJZ-C

Technische Daten

Modell
SED-60GJZ-C
Durchsatz
60 L/h
Spannung
220V 60Hz 3P
Versorgung
220V 60Hz 3-phase electrical supply, 3 kW; cooling water for jacket if processing heat-sensitive material; lubricating oil Mobil Gear SHC626 / ISO VG68
Konformitätsangaben
12-month warranty (SED standard); operating noise ≤80 dB
Leistung
3 kW

Abmessungen

Länge
722 mm
Breite
403 mm
Höhe
1326 mm
Gewicht
260 kg
Aufstellfläche
722 × 403 mm floor footprint, 1326 mm height; roller wheels at bottom (no anchor needed)

Werkstoffe

Kontaktwerkstoffe
Stainless steel piston/valve/pump body
Gehäusewerkstoffe
Steel pump body and frame; stainless wetted parts

Wesentliche Merkmale

Single-plunger high-pressure homogenizer
Max interval pressure 70 MPa (700 bar)
Continuous pressure 56 MPa (560 bar)
Rated capacity 60 L/h
Particle size 0.01-2 µm (avg 1 µm)
Two-stage homogenizing valve (high + low)
Min batch ~200 mL — true lab scale
Allowable operating temperature ≤100 °C
Noise ≤80 dB
Custom pressure gauge with vibration resistance, sensitive on rise, insensitive on drop, with manual zero-clearing
On rolling wheels — no floor anchor needed
Mobil Gear SHC626 (or ISO VG68) gearbox lube; 500-hour oil-change interval
Lab through pilot/null-series duty in one machine — same valve geometry as production homogenizers, results scale up
Two-stage high+low valve gives both narrow PSD and long seal life
Roller-mounted base lets the unit move between fume-hood, lab and pilot bench
Custom vibration-resistant pressure gauge designed for plunger pulsation
Detailed troubleshooting manual covers piston seal leaks, valve-seat wear, low/high pressure faults

Anwendungen

Cell disruption / intracellular product harvesting
Emulsion preparation (creams, parenteral lipid emulsions)
Liposome / nanoemulsion sub-micron dispersion
Genetic engineering sample prep
Food: dairy, plant protein, beverage homogenization
Chemical: pigment, ink, latex dispersions

Branchen

Pharma
Biotech / genetic engineering
Food
Chemical / coatings
Kosmetik

Komponentenhersteller

Custom single-plunger homogenizer pressure gauge (DC3V Li battery)
Mobil Gear SHC626 / ISO VG68 lubricant
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Reinigung und Wartung

After each product, flush pump body with cleaning fluid or water at 5 MPa low pressure until output runs clean. Disassemble homogenizing valve for deep clean as needed. Replace gearbox oil at 500 hours or sooner if emulsified by water ingress.

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→