SED-600ZQ2-T — Dampfgenerator

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

0.6-tonne (600 kg/h) once-through fully-premixed low-NOx gas steam generator. Vertical once-through water-tube structure; thermal efficiency up to 100.35 % (including condensate latent heat recovery). NOx emission <30 mg

Lieferzeit
Auf Anfrage
Durchsatz
0.6 T/H

Funktionsweise

Once-through structure: feed water first passes through the condenser to absorb flue-gas heat, then enters the lower header and absorbs heat through finned tubes. At approximately the midpoint (~1/2) the water vaporises to steam; the steam passes through the patented steam-water separator in the upper header; saturated steam is discharged while condensate recirculates via 3 once-through tubes back to the lower header. ±0.1° precision premixing of air:fuel ratio 1:9 ensures complete combustion. Italian Bekaert metal-fibre mesh radiant surface burner with flame temperature ~800 °C; low-temperature radiant combustion suppresses NOx formation. DC variable-frequency premix fan (FASCO/AMETEK) provides 9-stage linear output.

Prozessbeschreibung
1Once-through structure: feed water first passes through the condenser to absorb flue-gas heat, then enters the lower header and absorbs heat through finned tubes.
2At approximately the midpoint (~1/2) the water vaporises to steam; the steam passes through the patented steam-water separator in the upper header; saturated steam is discharged while condensate recirculates via 3 once-through tubes back to the lower header.
3±0.1° precision premixing of air:fuel ratio 1:9 ensures complete combustion.
4Italian Bekaert metal-fibre mesh radiant surface burner with flame temperature ~800 °C; low-temperature radiant combustion suppresses NOx formation.
5DC variable-frequency premix fan (FASCO/AMETEK) provides 9-stage linear output.

Technische Daten

Technische Daten für Variante: SED-600ZQ2-T

Technische Daten

Modell
SED-600ZQ2-T
Durchsatz
0.6 T/H
Spannung
380V 50Hz 3Φ
Konformitätsangaben
Water capacity <30 L — exempt from boiler/pressure-vessel supervision under 'Boiler Safety Technical Supervision Regulations'; national steam-equipment authority five-star certification; full argon-arc welding.
Leistung
2.2 kW
Luftdruck
1.0 MPa (rated working pressure)

Abmessungen

Länge
1900 mm
Breite
1100 mm
Höhe
2300 mm
Gewicht
1200 kg

Werkstoffe

Kontaktwerkstoffe
316L stainless steel (condenser); alloy boiler steel 5310 + stainless-steel finned tubes (furnace)
Gehäusewerkstoffe
Alloy boiler steel 5310; stainless-steel finned tubes; 316L stainless-steel condenser

Wesentliche Merkmale

Evaporation capacity: 600 kg/h
Rated working pressure: 1.0 MPa
Thermal efficiency: 100.35 % (including condensate latent heat)
NOx emission: <30 mg/m³
Flue-gas outlet temperature: <65 °C
Nine-stage linear modulation: 20 %–100 % (200–600 kg/h)
Steam-up: 2 min; rated pressure: 5 min
Water capacity <30 L (exempt from boiler registration / operator licence / annual inspection)
Furnace material: alloy boiler steel 5310 + stainless-steel finned tubes
Condenser: 316L stainless steel
Full argon-arc welding
Pld-iPower intelligent control system
7-inch LCD touchscreen + IoT remote monitoring
Steam outlet / combustion air inlet: DN25 flange
Feed-water pump motor: 2.2 kW (LEO Group)
Power supply: 380V
Thermal efficiency 100.35 % — saves ~24.9 % fuel vs. conventional boiler
Exempt from boiler registration, annual inspection, and operator licensing
No boiler operator required — fully automatic one-touch operation
NOx <30 mg/m³, meets strictest Tier-1 city standards
2-minute steam-up — no warm-up energy waste
Comprehensive safety protections: electronic over-pressure, mechanical safety valve, low-water, scale monitoring, earth-leakage, over-heat, flame-out, water-level logic
National steam-equipment five-star certification
Multi-unit group control + remote monitoring

Anwendungen

Pharmaceutical process heating
Moist-heat sterilisation
Steam source for drying equipment
Laundry-industry steam supply
Food-processing steam supply
Chemical reaction vessel heating

Branchen

Pharma
Chemical
Food
Laundry
Textile

Komponentenhersteller

Gas proportional valve
Honeywell
Venturi mixer
Honeywell
Gas pressure switch
Honeywell
DC variable-frequency premix fan
FASCO (AMETEK)
Surface burner metal-fibre mesh
Bekaert
Ignition transformer
Danfoss
Feed-water pump (custom)
LEO Group
Circuit breaker / contactor
Schneider
Pressure transmitter
Xuansheng
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→