Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
SED-5GZ-D
Auf Anfrage
SED-5GZ-D
SED · SED-5GZ-D · Hervorgehoben

SED-5GZ-D — Laboratory/Pilot Dry Granulator SED-5GZ-D

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-5GZ-D is a laboratory and pilot-scale dry granulator that integrates powder pre-compression feeding, roller compaction, and two-stage diagonal granulation in a single compact mobile unit. Minimum batch 5 g; continuou

cGMP-designedFDA-compliant non-metallic partsOptional 21 CFR Part 11 electronic records
Variante wählen (4)
Lieferzeit
Auf Anfrage
Durchsatz
1–5 kg/h

Funktionsweise

Dry granulation by roller compaction: powder is auger-fed by a vertical screw feeder into the nip between two vertically-arranged compaction rollers (40 mm diameter × 50 mm wide) at up to 15 kN/cm pressure, forming a ribbon 0.5–2.5 mm thick. The ribbon passes through a two-stage diagonal milling system — pre-mill stage followed by final-mill stage, each controlled independently by the PLC — to produce granules with a stable, controllable particle-size distribution. Sample ports between the rollers and between mill stages allow frequent process-parameter sampling typical of R&D and pilot work. The modular design fully separates the screw feeder from the compaction unit, so feed dynamics do not affect the roller compaction process.

Prozessbeschreibung
1Dry granulation by roller compaction: powder is auger-fed by a vertical screw feeder into the nip between two vertically-arranged compaction rollers (40 mm diameter × 50 mm wide) at up to 15 kN/cm pressure, forming a ribbon 0.5–2.5 mm thick.
2The ribbon passes through a two-stage diagonal milling system — pre-mill stage followed by final-mill stage, each controlled independently by the PLC — to produce granules with a stable, controllable particle-size distribution.
3Sample ports between the rollers and between mill stages allow frequent process-parameter sampling typical of R&D and pilot work.
4The modular design fully separates the screw feeder from the compaction unit, so feed dynamics do not affect the roller compaction process.

Technische Daten

Technische Daten für Variante: SED-5GZ-D (min 5 g

Technische Daten

Modell
SED-5GZ-D
Durchsatz
1–5 kg/h
Versorgung
Total installed power ~6 kW (roller motor 2.2 kW)
Leistung
6 kW

Abmessungen

Länge
800 mm
Breite
600 mm
Höhe
1200 mm
Gewicht
450 kg
Aufstellfläche
800 × 600 × 1200 mm (mobile unit); package 900 × 700 × 1300 mm, gross weight 500 kg; delivery 40 days

Werkstoffe

Kontaktwerkstoffe
Medical-grade stainless steel (rollers, hopper, screw feeder, granulator, all contact parts); non-metallic parts FDA-compliant
Gehäusewerkstoffe
Medical-grade stainless steel; modular fully-closed design

Wesentliche Merkmale

Minimum batch: 5 g — true R&D / pilot scale
Continuous capacity: 1–5 kg/h
Roller width: 50 mm; roller diameter: 40 mm
Maximum roller pressure: 15 kN/cm
Ribbon thickness: 0.5–2.5 mm (adjustable)
Two-stage diagonal granulation system (pre-mill + final mill, independently controlled)
Sample ports before and between mill stages for process analysis
Cantilever roller mounting for fast tear-down and cleaning
Modular fully-closed cGMP design
Mobile unit with integrated controls
Vertical roller arrangement eliminates gravity bias
Roller motor: 2.2 kW; total installed power: ~6 kW
Machine weight: ~450 kg; package gross weight: 500 kg
Dimensions: 800 × 600 × 1200 mm; package: 900 × 700 × 1300 mm
Yield: 65–85% (material-dependent)
Delivery: 40 days
Smallest batch in the SED-5GZ family — 5 g enables expensive biologic R&D
Designed to cGMP and FDA non-metallic compliance from the ground up
Optional CIP, optional 21 CFR Part 11 electronic records
URS-tailored: bespoke configuration to customer requirements
Mobile, integrated-control unit relocates easily across R&D bays
Cantilever rollers + modular construction = fast product changeover
PLC-driven roll-pressure compensation handles batch-to-batch material variability
Optional sound enclosure for lab environments

Anwendungen

Pharmaceutical R&D dry granulation
Clinical-trial / pilot batch granulation
Biologic and high-cost API granulation at small scale
Direct compaction of moisture- or heat-sensitive APIs
Process-parameter sampling for tech-transfer studies

Branchen

Pharmaceuticals (R&D, biologics)
Food
Chemicals
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

cGMP-designed
FDA-compliant non-metallic parts
Optional 21 CFR Part 11 electronic records

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→