SED · SED-3FGL-A · Hervorgehoben

SED-3FGL-A — Negative-Pressure Isolator

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-3FGL-A is a negative-pressure isolator (containment isolator) configured for high-potency or hazardous-material handling. It combines a sealed main chamber with material-transfer airlock and continuous-bag (continuou

Lieferzeit
Auf Anfrage
Durchsatz
Kontaktieren Sie uns

Funktionsweise

An EC scroll fan draws clean air through Camfil bag-in/bag-out HEPA drum filters into the main chamber, then exhausts it through PUSH-PUSH safe-change HEPA filters. By balancing supply and exhaust airflow with pneumatic butterfly valves, the controller maintains the chamber at negative pressure (monitored by Dwyer differential gauges/transmitter) so airborne dust cannot escape into the room. Operators manipulate product through gloves; product enters and leaves via the transfer airlock and continuous liner.

Prozessbeschreibung
1An EC scroll fan draws clean air through Camfil bag-in/bag-out HEPA drum filters into the main chamber, then exhausts it through PUSH-PUSH safe-change HEPA filters.
2By balancing supply and exhaust airflow with pneumatic butterfly valves, the controller maintains the chamber at negative pressure (monitored by Dwyer differential gauges/transmitter) so airborne dust cannot escape into the room.
3Operators manipulate product through gloves; product enters and leaves via the transfer airlock and continuous liner.

Technische Daten

Technische Daten für Variante: SED-3FGL-A

Technische Daten

Modell
SED-3FGL-A

Wesentliche Merkmale

Negative-pressure containment isolator with main chamber and material-transfer airlock
Continuous-bag (continuous liner) discharge, 300 mm diameter
Operator gloves on POM oval flanges (8 in. oval, 8 ports)
Camfil bag-in/bag-out HEPA filtration: 2x supply drum, 1x balance, 2x PUSH-PUSH safe-change
EBM EC scroll fan G3G160-CU09-11
Pneumatic double-acting butterfly isolation valves (Chengtong, 2 in. supply x2, 2.5 in. exhaust)
Pressure-cascade monitoring with five Dwyer 0-500 Pa gauges + 1 Dwyer +/-500 Pa transmitter
Siemens S7-200 SMART PLC with analog-output module
Deli Long TPC1162HN HMI and Haide E-500 SCADA
Schneider breakers (NSC60E3020N) and Y4 relays
Mean Well NDR-240-24 24 VDC power supply
Airtac valve-island, FRL pressure regulators, solenoid valves
15 mm Enqi tempered glass doors with hinges and safety locks
Parker SG-01-1 wash and air guns for clean-in-place
Philips internal backlight
Rotadler (Germany) 8 in. oval sterile gloves
BIBO HEPA filtration plus PUSH-PUSH safe change limits operator exposure during filter swaps
EC scroll fan with PLC-coordinated dampers gives stable negative pressure across load changes
Continuous liner outlet enables closed product transfer of OEB 4-5 class compounds
All major instrumentation (Dwyer, Camfil, EBM, Siemens, Schneider, Parker, Rotadler) sourced from internationally recognized brands

Anwendungen

Containment of high-potency APIs and toxic powders
Weighing, dispensing, sampling of OEB 4-5 class compounds
Sterile or aseptic operations requiring negative-pressure isolation
Continuous-liner unloading of hazardous powders

Branchen

Pharmaceutical containment (HPAPI, oncology, hormones)
Biopharma aseptic operations
Specialty chemicals with toxic dust exposure

Komponentenhersteller

HMI touchscreen
Deli Long (TPC1162HN)
SCADA software
Haide E-500
PLC CPU module
Siemens S7-200 SMART
Analog-output module
Siemens 6ES7 231-4HF32-0XB0
Network switch
Domestic EKI-2525
Pressure regulators (FRL)
Airtac GFC30008-F1
DC power supply
Mean Well NDR-240-24
Breakers
Schneider NSC60E3020N
Solenoid valve island
Airtac 100M-11F manifold + 4V110/3V110
Relays
Schneider Y4
Supply HEPA drum filter
Camfil 3202.04.00
Balance HEPA drum filter
Camfil 3201.01.00
PUSH-PUSH safe-change filter
Camfil 3206.03.00
PUSH-PUSH housing
Camfil 160 x 500 mm
EC centrifugal scroll fan
EBM G3G160-CU09-11
Supply pneumatic butterfly valve
Chengtong 2 in.
Exhaust pneumatic butterfly valve
Chengtong 2.5 in.
Differential pressure gauges
Dwyer 2000-500Pa
Differential pressure transmitter
Dwyer (-500 to +500 Pa)
Wash gun
Parker SG-01-1
Air gun
Parker SG-01-1
Backlight panel
Philips
Tempered glass (15 mm)
Enqi
Sterile gloves (8 in. oval)
Rotadler
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→