Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
Startseite / Maschinen / Wasserkühler / Air-Cooled Water Chiller (SED-1LSJ-G, 1 HP)
SED-1LSJ-G
Auf Anfrage
SED-1LSJ-G Air-Cooled Water Chiller
SED · SED-1LSJ-G · 19 verkaufte Einheiten

SED-1LSJ-G — Air-Cooled Water Chiller

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-1LSJ-G is a 1 HP air-cooled water chiller with 3.6 kW (3,200 kcal/hr) cooling capacity. Designed to provide chilled water at 5-35°C for cooling pharmaceutical packaging machines (such as water-cooled aluminum-foil in

Standard refrigeration safety protections per industry normsR22/R407 refrigerant compliant with refrigerant regulations at production date
Variante wählen (1)
Lieferzeit
Auf Anfrage
Durchsatz
1000 m3

Funktionsweise

Standard vapor-compression refrigeration cycle: the fully sealed scroll compressor compresses R22/R407 refrigerant to high-pressure vapor; the wind-cooled finned condenser (1000 m³ axial fan flow) rejects heat to ambient air; capillary expansion drops pressure; the coil-type evaporator absorbs heat from the recirculating water in the 20 L stainless steel tank, chilling it to the 5-35°C setpoint. The internal 0.37 kW pump (20 m head) circulates chilled water through 1" inlet/outlet pipes to the user equipment at 0.48 m³/hr. Comprehensive safeties (compressor over-heat, over-current, high/low pressure, over-temp, flow, phase sequence, exhaust over-heat, anti-freeze) cut the unit on fault.

Prozessbeschreibung
1Standard vapor-compression refrigeration cycle: the fully sealed scroll compressor compresses R22/R407 refrigerant to high-pressure vapor; the wind-cooled finned condenser (1000 m³ axial fan flow) rejects heat to ambient air; capillary expansion drops pressure; the coil-type evaporator absorbs heat from the recirculating water in the 20 L stainless steel tank, chilling it to the 5-35°C setpoint.
2The internal 0.37 kW pump (20 m head) circulates chilled water through 1" inlet/outlet pipes to the user equipment at 0.48 m³/hr.
3Comprehensive safeties (compressor over-heat, over-current, high/low pressure, over-temp, flow, phase sequence, exhaust over-heat, anti-freeze) cut the unit on fault.

Technische Daten

Technische Daten für Variante: SED-1LSJ-G 1 HP air-cooled chiller

Technische Daten

Modell
SED-1LSJ-G
Durchsatz
1000 m3
Spannung
1 HP, 220V/50Hz einphasig
Versorgung
AC 220V/50Hz single-phase electric supply (1.3 kW input); make-up water for the 20 L tank; clean ambient air intake (no compressed air needed)
Konformitätsangaben
Standard refrigeration safety devices; R22/R407 refrigerant compliant with current refrigerant regulations at production date; pharmaceutical-grade chilled water output suitable for GMP-relevant equipment
Leistung
1.3 kW
Luftdruck
Not applicable (water chiller)

Abmessungen

Länge
550 mm
Breite
500 mm
Höhe
920 mm
Gewicht
80 kg
Aufstellfläche
0.55 m (L) x 0.5 m (W) x 0.92 m (H); allow 0.5 m clearance around the air-cooled condenser fan for airflow

Werkstoffe

Kontaktwerkstoffe
Copper tubing; stainless steel insulated water tank; standard pump materials
Gehäusewerkstoffe
Painted steel cabinet; stainless steel water tank insulation

Komponenten

Compressor Type
hermetic scroll (piston)
Condenser Type
air-cooled shell-and-tube, red copper + aluminum fins + low-noise axial fan
Evaporator Type
tank with coil (shell and tube)
Refrigerant Control
capillary vessel

Elektrik

Pump Power
0.37 kW

Betrieb

Chilled Fluid Flow
0.48 m³/h
Cooling Air Flow
1000 m³/h
Cooling Capacity
3600 W
Pump Lift
20 m

Physikalische Angaben

Inlet/Outlet Pipe Diameter
1" inch
Tank Volume
18.5 L

Wesentliche Merkmale

1 HP cooling capacity — 3.6 kW (3,200 kcal/hr)
Fully sealed scroll compressor — low noise, high efficiency, long life
Wind-cooled (no cooling tower needed) — high-efficiency copper pipe with aluminum fins + low-noise axial fan
Coil-type evaporator with stainless steel insulated 20 L water tank
Built-in 0.37 kW water pump (20 m head)
Chilled water output 0.48 m³/h via 1" inlet/outlet pipes
Cooling range 5°C-35°C
R22 / R407 environmentally friendly refrigerant
Comprehensive safeguards: compressor over-heat, over-current, high/low pressure, over-temp, flow, phase, exhaust over-heat, anti-freeze
Single-phase 220V/50Hz, 1.3 kW input
Compact 550 x 500 x 920 mm; 80 kg
Plug-and-play air-cooled chiller — no cooling-tower install required
Right-sized at 3.6 kW for typical capsule fillers, tablet presses with mold cooling, and water-cooled induction sealers
Single-phase 220V means it runs anywhere SED machines run
Imported original compressor — quieter and longer-lasting than commodity chillers
Comprehensive safety protections protect the connected machine and the chiller itself
Affordable at $950-1,100 FOB
Stainless steel insulated tank — long water-temperature stability

Anwendungen

Cooling water supply for water-cooled aluminum-foil induction sealing machines
Cooling for capsule filling machines requiring chilled water (gel mold cooling)
Tablet press mold and main-shaft cooling
Cooling for laboratory equipment and analytical instruments
Process water chilling for small pharma equipment
Cosmetics and food processing equipment cooling

Branchen

Pharmazeutische Herstellung
Nahrungsergänzungsmittel und Nutrazeutika
Food and beverage processing
Cosmetics manufacturing
Laboratory / analytical
Plastic injection molding (small machines)

Komponentenhersteller

Imported scroll compressor (original) — fully sealed type
High-efficiency copper-tube + aluminum-fin condenser
Low-noise axial fan
Stainless steel insulated water tank
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

Standard refrigeration safety protections per industry norms
R22/R407 refrigerant compliant with refrigerant regulations at production date

Reinigung und Wartung

Inspect and clean the finned condenser regularly to maintain heat-transfer efficiency. Drain and refill the water tank periodically to prevent algae growth. Check refrigerant pressure annually via certified technician. Verify safety devices (high/low pressure, anti-freeze, flow) function before each season. Keep the air-cooled condenser intake free of dust and obstructions.

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→