Ausstellung in Ontario, Kalifornien · Support am Zielort anfragen
Startseite / Maschinen / Wägekabine / Dispensing Booth / Weighing Room
SED-13-13-24CLS-J
Auf Anfrage
SED-13-13-24CLS-J
SED · SED-13-13-24CLS-J · Hervorgehoben

SED-13-13-24CLS-J — Dispensing Booth / Weighing Room

Die vollständige Beschreibung dieses Modells wird noch übersetzt. Lesen Sie die englischen Details oder fragen Sie unser Team nach weiteren Informationen. English

SED-13-13-24CLS-J explosion-proof negative-pressure dispensing booth system. Outer 1300×1300×2400 mm, inner 1200×1050×2000 mm. Includes: dispensing booth body (SUS304, aluminum-frame liquid-tank HEPA filter 99.99%@0.3μm

GMP Grade A (US 209E static Class 100)Explosion-proofDQ/IQ/OQ validation documentation fully provided
Lieferzeit
Auf Anfrage
Durchsatz
300 kg/batch

Funktionsweise

The air-supply filter box draws workshop air through a VFD fan, pre-filtered through G4 and F7 filters, into the dispensing booth. Inside the booth, an aluminum-frame liquid-tank H13/H14 HEPA filter (99.99%@0.3μm) further purifies air delivered to the work zone, maintaining GMP Grade A (US 209E static Class 100) cleanliness. Wind speed sensor continuously monitors and auto-adjusts fan speed. Exhaust from the booth bottom passes through a bag-in-bag-out (BIBO) H14 HEPA filter (99.995%@MPPS) via exhaust fan to outdoor/rooftop, maintaining overall negative pressure to prevent powder leakage. Three differential pressure switches monitor initial/mid/HEPA filter resistance and alarm for replacement. Color LCD HMI controls wind speed, filter countdown reminder, and UV sterilization timer. Entire system is explosion-proof design.

Prozessbeschreibung
1The air-supply filter box draws workshop air through a VFD fan, pre-filtered through G4 and F7 filters, into the dispensing booth.
2Inside the booth, an aluminum-frame liquid-tank H13/H14 HEPA filter (99.99%@0.3μm) further purifies air delivered to the work zone, maintaining GMP Grade A (US 209E static Class 100) cleanliness.
3Wind speed sensor continuously monitors and auto-adjusts fan speed.
4Exhaust from the booth bottom passes through a bag-in-bag-out (BIBO) H14 HEPA filter (99.995%@MPPS) via exhaust fan to outdoor/rooftop, maintaining overall negative pressure to prevent powder leakage.
5Three differential pressure switches monitor initial/mid/HEPA filter resistance and alarm for replacement.
6Color LCD HMI controls wind speed, filter countdown reminder, and UV sterilization timer.
7Entire system is explosion-proof design.

Technische Daten

Technische Daten für Variante: SED-13-13-24CLS-J

Technische Daten

Modell
SED-13-13-24CLS-J
Durchsatz
300 kg/batch
Spannung
220V/50Hz
Versorgung
220V/50Hz power; booth body 2.3kW + supply VFD fan 2.2kW (total ~4.5kW); exhaust duct to outdoor or rooftop
Konformitätsangaben
Full explosion-proof design; GMP Grade A (US 209E static Class 100); H14 HEPA 99.995%@MPPS BIBO exhaust filtration; H13/H14 99.99%@0.3μm supply-air filtration; PAO/DOP test ports included; complete DQ/IQ/OQ validation documents; 45-day lead time; EXW Nantong; 30% TT deposit.
Leistung
4.5 kW

Abmessungen

Länge
1300 mm
Breite
1300 mm
Höhe
2400 mm
Aufstellfläche
Booth outer 1300×1300×2400mm; inner 1200×1050×2000mm; work table 700×1000×900mm; plus air-supply filter box + exhaust filter + exhaust duct to rooftop/outdoors

Werkstoffe

Kontaktwerkstoffe
SUS304 high-quality sanded stainless steel (booth interior surface, work table top)
Gehäusewerkstoffe
SUS304 stainless steel (booth, exhaust filter 2.0mm, work table 40×40 square tube frame); aluminum frame (liquid-tank HEPA filter frame)

Wesentliche Merkmale

Explosion-proof negative-pressure dispensing booth
Outer 1300×1300×2400mm / Inner 1200×1050×2000mm
GMP Grade A cleanliness (US 209E static Class 100)
H13/H14 HEPA 99.99%@0.3μm (booth) + H14 HEPA 99.995%@MPPS (BIBO exhaust)
G4 prefilter + F7 mid-efficiency supply-air filtration
Supply-air VFD fan 2200 CMH/1000Pa/2.2kW
Bag-in-bag-out exhaust 2500 CMH
Color LCD touchscreen control: wind speed/filter timer/UV timer
US Dwyer pressure gauges for real-time filter resistance monitoring
Wind speed sensor auto-adjusts fan speed
Three DP-switches alarm, PID auto VFD
PAO/DOP test ports ensure filter integrity
Full system explosion-proof design
DQ/IQ/OQ complete validation documentation provided
SUS304 work table 700×1000×900mm (40×40 square tube + sanded top + leveling feet)
GMP Grade A + explosion-proof dual requirements met in one system
Bag-in-bag-out (BIBO) exhaust system prevents powder leakage during maintenance
Complete DQ/IQ/OQ validation documents (regulatory requirement)
US Dwyer pressure gauges + German/European wind speed sensor
Explosion-proof design for flammable pharmaceutical/API weighing
45-day lead time; EXW Nantong; 30% TT deposit
PAO/DOP test ports for annual filter integrity testing

Anwendungen

API/intermediate weighing (explosion-proof environment)
Flammable/explosive powder weighing
GMP Grade A pre-production weighing
Highly potent API (HPAPI) safe weighing
Aseptic formulation API weighing

Branchen

Pharma
API/raw material drug
Highly potent compounds (HPAPI)
Flammable chemicals/fine chemicals

Komponentenhersteller

US Dwyer 0–250/0–500Pa pressure gauge
US Dwyer 2000-type 750Pa pressure gauge (exhaust)
SED
Sprechen Sie mit SED Sales Team
Maschinenspezialisten · Kontakt per WhatsApp
Geschäftszeiten und Verfügbarkeit beim Team erfragen

Konformität

GMP Grade A (US 209E static Class 100)
Explosion-proof
DQ/IQ/OQ validation documentation fully provided

Dokumentation

Datenblatt (PDF)
Überblick, technische Daten und Abmessungen · Originaldokument (Englisch)
Beim Vertrieb anfragen
Bedienhandbuch
Einrichtung, Betrieb und Fehlersuche · Originaldokument (Englisch)
Beim Vertrieb anfragen
Vergleichsdatenblatt (Standard und Economy)
Vergleich der Konfigurationen · Originaldokument (Englisch)
Beim Vertrieb anfragen
IQ / OQ / PQ-Protokolle
Validierungsunterlagen zur GMP-Konformität · Originaldokument (Englisch)
Beim Vertrieb anfragen
FAT / SAT-Protokolle
Abnahmeprüfungen im Werk und vor Ort · Originaldokument (Englisch)
Beim Vertrieb anfragen
CAD-Zeichnungen (STEP / IGES / DWG)
Konstruktionszeichnungen für die Aufstellung · Originaldokument (Englisch)
Beim Vertrieb anfragen
Kalibrierzertifikate
Schallpegel, Erdungswiderstand, Spannungsfestigkeit und Rauheit · Originaldokument (Englisch)
Beim Vertrieb anfragen
DQ (Designqualifizierung)
Vollständiges Designqualifizierungsprotokoll · Originaldokument (Englisch)
Beim Vertrieb anfragen
Werkstoffzeugnisse
Zusammensetzung des Edelstahls 316L · Originaldokument (Englisch)
Beim Vertrieb anfragen
SED
WhatsApp · SED Vertrieb
Vertriebskontakt · WhatsApp
→