SED-8200MJT-3 — Hot-Air-Circulation Tunnel Sterilization & Drying Oven
لا تزال ترجمة الوصف الكامل لهذا الطراز قيد العمل. راجع التفاصيل بالإنجليزية أو اطلب المعلومات من فريقنا. English
SED-8200MJT-3 hot-air-circulation tunnel sterilization & drying oven for pharmaceutical bottle drying and depyrogenation. ~17 m stainless-steel woven belt carries pre-washed 100–500 ml vials through pre-heating,three hig
مبدأ العمل
Pre-washed vials are loaded onto a 304 stainless-steel woven belt(≈1250 mm wide, 50–500 mm/min). Bottles travel through a 780 mm pre-heat zone, three high-temp zones(1428+1314+1314 mm = 4056 mm) sterilizing at up to 350°C with HEPA-filtered Class-100 laminar hot-air circulation, then through 2 cooling zones(1872+1492 mm = 3364 mm) with water-cooled coils to ≤35°C exit temp. Heat-rated fans drive the air through HEPA filters, returning humid air via dedicated exhaust blowers. Servo-controlled lift gates seal the inlet/outlet to prevent contamination ingress.