SED-500WRO-H — Two-Stage Reverse Osmosis, 0.5 T/h
لا تزال ترجمة الوصف الكامل لهذا الطراز قيد العمل. راجع التفاصيل بالإنجليزية أو اطلب المعلومات من فريقنا. English
SED-500WRO-H pharmaceutical water-treatment system: 0.5 T/h two-stage reverse osmosis (RO) skid. Includes raw-water tank + level controller + raw-water pump; multimedia pretreatment train (quartz-sand filter, granular ac
مبدأ العمل
Raw water is pumped from the raw-water tank through a quartz-sand filter(suspended-solids removal), an activated-carbon filter(chlorine and organics removal), and a softener(Na⁺ ion-exchange to remove Ca/Mg hardness). Water then passes through a 5-μm precision cartridge filter and a 1st-stage high-pressure pump driving Stage-1 RO(3×4040 polyamide membranes in stainless-steel pressure vessels US4040-1). Stage-1 permeate feeds a 2nd-stage high-pressure pump and Stage-2 RO(2×4040 elements). Final permeate is collected in a 0.5 T sterile-water tank, polished by an in-line UV sterilizer, then distributed by a VFD-controlled supply pump. Automatic membrane-flush solenoid valves backwash on cycle.
المواصفات الفنية
المواصفات
الأبعاد
المواد
الخصائص الرئيسية
التطبيقات
القطاعات
العلامات التجارية للمكونات
التنظيف والصيانة
Automatic membrane-flush via solenoid valves on each RO stage. Manual daily maintenance required: cartridge filter element replacement as needed, tank inspection, log conductivity readings per stage.