Showroom em Ontario, Califórnia · Consulte o suporte para seu destino
Início / Equipamentos / Lavadora de rolhas de borracha / SED-KJWZ-L Sterile Bag Discharge Transfer System (Double-Bag Single-Seal oRABS)
SED-KJWZ-L
Consultar
SED-KJWZ-L
SED · SED-KJWZ-L · Em destaque

SED-KJWZ-L — SED-KJWZ-L Sterile Bag Discharge Transfer System

A descrição completa deste modelo ainda está sendo traduzida. Consulte os detalhes em inglês ou solicite informações à nossa equipe. English

The SED-KJWZ-L is a sterile bag (double-bag single-seal) discharge transfer system designed to mount on the discharge end of a rubber stopper / aluminum cap washer. It functions as an open Restricted Access Barrier Syste

Escolher variante (2)
Prazo de entrega
Consultar
Capacidade de produção
Fale conosco

Como funciona

Sterile double bags are placed inside the chamber via the side door (after exterior decontamination). Operator engages pneumatic clamps front and rear to fix outer bag, then inner bag (front/rear with point-touch interlock for safety). Heat sealer is pushed forward to align with washer discharge spout. Left foot pedal arms the sealer; right foot pedal triggers stopper/cap discharge from the washer (filling time and quantity controlled by pedal release). After fill, sealer retracts; operator manually ties inner bag with cable tie; second left-pedal press auto-flattens and heat-seals the outer bag (160–170°C, 0.4 MPa, 0.8–1.2 s, ±0.2°C control). Side door 2 opens to discharge sealed bag via the platform exit area to a transport cart bound for the filling line. Internal H14 HEPA + German EBM VFD-controlled blower maintains downflow at 0.36–0.54 m/s; UV lamp + LED illuminate. Differential pressure gauges monitor HEPA loading and chamber pressure; glove door alarm triggers if opened in operation to protect chamber positive pressure.

Processo de funcionamento
1Sterile double bags are placed inside the chamber via the side door (after exterior decontamination).
2Operator engages pneumatic clamps front and rear to fix outer bag, then inner bag (front/rear with point-touch interlock for safety).
3Heat sealer is pushed forward to align with washer discharge spout.
4Left foot pedal arms the sealer; right foot pedal triggers stopper/cap discharge from the washer (filling time and quantity controlled by pedal release).
5After fill, sealer retracts; operator manually ties inner bag with cable tie; second left-pedal press auto-flattens and heat-seals the outer bag (160–170°C, 0.4 MPa, 0.8–1.2 s, ±0.2°C control).
6Side door 2 opens to discharge sealed bag via the platform exit area to a transport cart bound for the filling line.
7Internal H14 HEPA + German EBM VFD-controlled blower maintains downflow at 0.36–0.54 m/s; UV lamp + LED illuminate.
8Differential pressure gauges monitor HEPA loading and chamber pressure; glove door alarm triggers if opened in operation to protect chamber positive pressure.

Especificações técnicas

Especificações da variante: GLG2000-PS: oRABS isolation cabinet

Especificações

Modelo
SED-KJWZ-L
Tensão
AC 220V, 50Hz
Utilidades
AC 220V 50Hz electrical supply (1 kW oRABS + heat sealer); compressed air at 0.4 MPa via φ8 mm PU line for pneumatic clamps and heat seal; mounted at washer discharge end; environment must be Class B cleanroom
Detalhes de conformidade
Class A / ISO 5 inside chamber per cGMP; designed for Class B cleanroom environment; particle limits: ≥0.5 μm ≤3520/m³, ≥5.0 μm ≤20/m³; differential pressure to surroundings 5–10 Pa positive; HEPA initial resistance ≤160 Pa, terminal 320 Pa; total noise <70 dBA; PAO integrity test port for HEPA validation
Potência
1 kW
Pressão de ar
0.4 MPa (sealing); φ8mm PU air line

Dimensões

Comprimento
2300 mm
Largura
650 mm
Altura
2450 mm
Peso
430 kg
Área de instalação
2300 mm × 650 mm × 2450 mm (oRABS cabinet); 820 mm × 420 mm × 760 mm (heat sealer)

Materiais

Materiais de contato
All product-contact and chamber-internal surfaces SUS304 stainless steel (frame, sealing plates, intake plates, heat sealer support and cover) with internal Ra≤0.8 surface finish; sterile bags and HYPALON gloves
Materiais do corpo
SUS304 50×50 mm rectangular tube frame and plate cladding (external Ra≤0.8); 8 mm tempered glass operation doors (4 outward-opening); 6 mm glass side doors (manual synchronous belt lift); nylon side door rails; SUS304 stainless steel support feet; flame-retardant moisture-resistant fiberglass HEPA media

Características principais

Double-bag single-seal design — inner cable-tied + outer heat-sealed
Heat sealer slides fore/aft to clear washer discharge during sealing
ISO 5 / Class A cleanliness inside unit, operated from Class B room
H14 HEPA filter @ 99.995% efficiency on 0.3 μm particles
German EBM direct-drive radial blower with VFD speed control
Two pairs of US NORTH HYPALON sterile gloves (8" or 10" elliptical mounts)
UV sterilization lamp + LED lighting
3 differential pressure gauges + 1 temperature/humidity gauge
PAO test port for HEPA integrity validation
Foot-pedal-controlled stopper discharge (operator hands stay at clamps)
Glove-door interlock alarm protects chamber positive pressure
Adjustable height-from-floor for washer alignment
Heat seal: 160–170°C, ±0.2°C, 0.4 MPa, 0.8–1.2 s on 550×4 mm seal face
Eliminates manual bagging exposure of sterile stoppers/caps after washing
Pre-fixed double-bag avoids re-bagging large filled bag (operator ergonomic)
Inner-bag tie + outer-bag heat seal prevents heat-seal residue contamination of stoppers
Sliding sealer keeps heat away from washer discharge port — protects washed stoppers
Sub-70 dBA noise inside Class B suite
Top-tier: Siemens PLC, EBM blower, NORTH gloves, Dwyer pressure sensors, Philips lamps

Aplicações

Sterile transfer of washed rubber stoppers from washer to filling line
Sterile transfer of washed aluminum overcaps to capping line
Bagged sterile transfer for vial filling and lyo loading lines
B-grade cleanroom operations requiring local A-grade environment

Setores

Sterile injectable pharmaceuticals
Antibiotic powder and liquid injection manufacturing
Vaccine and biologics filling
Lyophilized product manufacturing

Marcas dos componentes

Siemens (S7-200Smart-SR40 PLC, EM DR08/AM06/AE04 modules)
proface (7" touchscreen HMI)
EBM Germany (direct-drive HEPA blower)
NORTH USA (HYPALON sterile gloves)
Philips (UV lamp 8W, LED light 14W)
Dwyer (differential pressure sensors)
Suzhou Sujing (laminar flow membrane)
Chint (contactors)
Klockner Moeller / Eaton (circuit breakers)
MW Mean Well (DC24V switching power supply)
SED
Fale com SED Sales Team
Especialistas em equipamentos · contato pelo WhatsApp
Consulte o horário e a disponibilidade da equipe

Documentação

Ficha técnica (PDF)
Visão geral do equipamento, especificações e dimensões · Documento original (inglês)
Solicitar à equipe de vendas
Manual do operador
Instalação, operação e diagnóstico · Documento original (inglês)
Solicitar à equipe de vendas
Folha comparativa (Padrão e Econômica)
Comparação das configurações · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos IQ / OQ / PQ
Documentação de validação para conformidade GMP · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos FAT / SAT
Testes de aceitação na fábrica e no local · Documento original (inglês)
Solicitar à equipe de vendas
Desenhos CAD (STEP / IGES / DWG)
Desenhos de engenharia para a instalação · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de calibração
Nível sonoro, resistência de terra, rigidez dielétrica e rugosidade · Documento original (inglês)
Solicitar à equipe de vendas
DQ (qualificação do projeto)
Protocolo completo de qualificação do projeto · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de materiais
Composição do aço inoxidável 316L · Documento original (inglês)
Solicitar à equipe de vendas
SED
WhatsApp · Vendas SED
Contato comercial · WhatsApp
→