The SED-48S-T is a fully automatic 48-channel electronic counting machine composed of two 24-channel dual-hopper counting units combined into a single integrated system. Designed and manufactured to GMP standard, it is s

Prazo de entrega
Consultar
Capacidade de produção
10–120 frascos/min

Como funciona

Product is placed into the hopper and fed via vibrating three-stage vibration trays (24 channels per unit, 48 total) sequentially into counting photoelectric boxes. Each channel has a dedicated gate solenoid valve; when the pre-set count is reached, the gate closes. Once a new empty bottle is positioned, the gate opens and the dose drops into the bottle. Anti-high-dust photoelectric sensors ensure counting accuracy. Bottle-shortage and bottle-jam photoelectrics trigger automatic stop. The system supports stepless vibration speed adjustment to reduce tablet breakage.

Processo de funcionamento
1Product is placed into the hopper and fed via vibrating three-stage vibration trays (24 channels per unit, 48 total) sequentially into counting photoelectric boxes.
2Each channel has a dedicated gate solenoid valve; when the pre-set count is reached, the gate closes.
3Once a new empty bottle is positioned, the gate opens and the dose drops into the bottle.
4Anti-high-dust photoelectric sensors ensure counting accuracy.
5Bottle-shortage and bottle-jam photoelectrics trigger automatic stop.
6The system supports stepless vibration speed adjustment to reduce tablet breakage.

Especificações técnicas

Especificações da variante: SED-48S-T

Especificações

Modelo
SED-48S-T
Capacidade de produção
10–120 frascos/min
Utilidades
Electrical: 220V/50Hz, 1.8 kW; Compressed air: 0.6 MPa

Materiais

Materiais de contato
316L stainless steel (product-contact parts); 304 stainless steel (indirect contact)
Materiais do corpo
304 stainless steel with high-precision polishing

Características principais

48-channel counter = 2 × 24-channel dual-hopper units
Anti-high-dust photoelectric counting technology
GMP-standard design (all-box rotating parts for dust resistance, lubrication, and cleanability)
Siemens PLC (1515SP) and Siemens HMI (KTP900 Basic)
MAC solenoid valve group (24 pcs) for precise gate control
Stepless vibration speed adjustment (reduces tablet chip/breakage)
Bottle-shortage and bottle-jam auto-stop
Supports multi-language HMI; stores dozens of parameter groups
Can connect external storage to expand parameter storage
Two-unit 24-channel design provides 48 channels for high throughput
Siemens PLC and HMI for reliable, GMP-grade control
Anti-high-dust counting sensors ensure accuracy in dusty pharmaceutical environments
Stepless vibration control minimizes tablet damage

Aplicações

Counting and bottling tablets (plain, shaped, sugar-coated)
Counting and bottling hard capsules (all sizes) and soft capsules
High-throughput pharmaceutical bottle-filling lines

Setores

Farmacêutico
Health supplement / nutraceutical
Chemical
Food

Marcas dos componentes

PLC: Siemens — 1515SP PC 2GB
HMI: Siemens — KTP900 Basic
Frequency converter: Siemens — V20 0.37kW (×2)
Solenoid valve group: MAC — 44C-ABA-GDFA-1GA (×24)
Vibration feed controller: CUH — SDVC34-MR (×6)
Counting device: IMS — CMXYT12.3.NPN V30 (×2)
Switch power supply: Omron — S8VK-G10A
Cylinder: AirTAC — TN 10×60/80-S (×2)
Cylinder: SMC — CXSM10-35 (×2)
Cylinder (gate): SMC — CJ2KB16-40Z (×24)
Solenoid valve: FESTO — LK14-M52-AT (×14)
Relay: Panasonic — AHN22324N (×4)
Photoelectric: LEUZE — HRTR 5.1/2 (×3)
Emergency stop button: Schneider — ZB2-BS54C
Motor: Maili — 5RK120GU-SF (×2)
SED
Fale com SED Sales Team
Especialistas em equipamentos · contato pelo WhatsApp
Consulte o horário e a disponibilidade da equipe

Documentação

Ficha técnica (PDF)
Visão geral do equipamento, especificações e dimensões · Documento original (inglês)
Solicitar à equipe de vendas
Manual do operador
Instalação, operação e diagnóstico · Documento original (inglês)
Solicitar à equipe de vendas
Folha comparativa (Padrão e Econômica)
Comparação das configurações · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos IQ / OQ / PQ
Documentação de validação para conformidade GMP · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos FAT / SAT
Testes de aceitação na fábrica e no local · Documento original (inglês)
Solicitar à equipe de vendas
Desenhos CAD (STEP / IGES / DWG)
Desenhos de engenharia para a instalação · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de calibração
Nível sonoro, resistência de terra, rigidez dielétrica e rugosidade · Documento original (inglês)
Solicitar à equipe de vendas
DQ (qualificação do projeto)
Protocolo completo de qualificação do projeto · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de materiais
Composição do aço inoxidável 316L · Documento original (inglês)
Solicitar à equipe de vendas
SED
WhatsApp · Vendas SED
Contato comercial · WhatsApp
→