Showroom em Ontario, Califórnia · Consulte o suporte para seu destino
Início / Equipamentos / Contadora fotoelétrica — poucos canais (S/SD, ≤10) / Capsule/Tablet Counting Bottling Line - Fully Automatic Electronic Counting Machine
SED-2S-H
Consultar
SED-2S-H
SED · SED-2S-H · Em destaque

SED-2S-H — Capsule/Tablet Counting Bottling Line - Fully Automatic Electronic Counting Machine

A descrição completa deste modelo ainda está sendo traduzida. Consulte os detalhes em inglês ou solicite informações à nossa equipe. English

SED-2S-H fully automatic rotary electronic counting machine. Built on SED-1S-H with added conveyor and movable feet to free up the operator's hands. Uses internationally advanced vibrating feed (variable-frequency oscill

GMP-compliant design
Escolher variante (2)
Prazo de entrega
Consultar
Capacidade de produção
600–2000 unidades/min

Como funciona

Tablets/capsules/pills feed from the storage hopper to the material turntable, then onto the vibrating plate where amplitude-modulated vibration sends pieces in single file through the counting box. Keyence optical-fiber sensing heads count each piece by infrared beam break. PLC tracks count per channel; when the preset bottle quantity is reached the discharge gate opens and pieces drop into the bottle on the conveyor below. A bottle width adjuster guides bottles; a conveyor up-down adjuster sets fill height; an Omron fiber probe detects bottle presence (no-bottle-no-fill).

Processo de funcionamento
1Tablets/capsules/pills feed from the storage hopper to the material turntable, then onto the vibrating plate where amplitude-modulated vibration sends pieces in single file through the counting box.
2Keyence optical-fiber sensing heads count each piece by infrared beam break.
3PLC tracks count per channel; when the preset bottle quantity is reached the discharge gate opens and pieces drop into the bottle on the conveyor below.
4A bottle width adjuster guides bottles; a conveyor up-down adjuster sets fill height; an Omron fiber probe detects bottle presence (no-bottle-no-fill).

Especificações técnicas

Especificações da variante: SED-1S-H (predecessor - no conveyor

Especificações

Modelo
SED-2S-H
Capacidade de produção
600–2000 unidades/min
Tensão
220V/50-60Hz
Utilidades
Electrical: 220V/50-60Hz, 0.8 kW; user-supplied air compressor required
Potência
0.8 kW

Dimensões

Comprimento
1300 mm
Largura
570 mm
Altura
1300 mm
Peso
120 kg

Materiais

Materiais de contato
aço inoxidável 304 (0Cr18Ni9)
Materiais do corpo
aço inoxidável 304; tempered glass (turntable)

Características principais

Throughput: 600-2000 pcs/min
Counting accuracy: +/-0.1%
Application: hard capsules, soft capsules, tablets, pills
Capsule range: 000#-5#; tablet diameter 5-25 mm
Touchscreen PLC intelligent control (Siemens)
Vibrating feed with variable-amplitude oscillator
Keyence optical-fiber infrared counting heads
System self-inspection, fault indication alarm, auto-stop
Omron optical-fiber probe - no-bottle-no-fill detection
Built-in conveyor - frees operator's hands
Movable feet for flexible relocation
All 304 stainless steel (0Cr18Ni9), GMP-compliant
GMP-standard design with sealed dust-poor flow path
Premium control stack: Siemens PLC + 7-inch HMI, Keyence fiber counters, Airtac pneumatics
High counting accuracy +/-0.1% rivaling international competitors
Compact (only 0.8 kW, 120 kg) - fits small benchtop pharma packaging cells
Movable feet + conveyor - flexible deployment vs. fixed turntable predecessor SED-1S-H

Aplicações

Hard capsule counting
Soft gelatin capsule counting
Tablet counting
Pill counting
Transparent soft capsule counting

Setores

Pharmaceutical packaging
Nutraceutical / dietary supplements
TCM / herbal pills

Marcas dos componentes

7-inch HMI Touchscreen
Siemens 6AV6648-ODC11-3AXO
PLC
Siemens 6ES7288-1ST20-0AA1
Optical fiber sensor
Keyence FS-N41N / FS-N18N
Optical fiber sensing head
Keyence FU-E40 / FU-6F
Bottle-presence fiber probe
Omron
Motor 4RK40RGN-C / 5GU-75-K
Zhejiang Tongli
Oscillator (variable amplitude)
Self-made
Solid state relay (SSR-10 DD)
Yangming Taiwan
Electromagnet (JF-1253)
Jifa Wenzhou
Intermediate relay (RJ1S-CL-D24)
IDEC
Solenoid valve / FRL / cylinders (4N210-08-B / AFR-2000 / TN10X10-S / MI10X15-S-CA)
AIRTAC
SED
Fale com SED Sales Team
Especialistas em equipamentos · contato pelo WhatsApp
Consulte o horário e a disponibilidade da equipe

Conformidade

GMP-compliant design

Documentação

Ficha técnica (PDF)
Visão geral do equipamento, especificações e dimensões · Documento original (inglês)
Solicitar à equipe de vendas
Manual do operador
Instalação, operação e diagnóstico · Documento original (inglês)
Solicitar à equipe de vendas
Folha comparativa (Padrão e Econômica)
Comparação das configurações · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos IQ / OQ / PQ
Documentação de validação para conformidade GMP · Documento original (inglês)
Solicitar à equipe de vendas
Protocolos FAT / SAT
Testes de aceitação na fábrica e no local · Documento original (inglês)
Solicitar à equipe de vendas
Desenhos CAD (STEP / IGES / DWG)
Desenhos de engenharia para a instalação · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de calibração
Nível sonoro, resistência de terra, rigidez dielétrica e rugosidade · Documento original (inglês)
Solicitar à equipe de vendas
DQ (qualificação do projeto)
Protocolo completo de qualificação do projeto · Documento original (inglês)
Solicitar à equipe de vendas
Certificados de materiais
Composição do aço inoxidável 316L · Documento original (inglês)
Solicitar à equipe de vendas
SED
WhatsApp · Vendas SED
Contato comercial · WhatsApp
→