The SED-8SX4-S is a complete automatic tablet/capsule counting and bottling production line. The core machine is the SED-8S-S 8-channel vision imaging electronic tablet counter, capable of 20–120 bottles per minute depen

GMP
Délai de livraison
Sur devis
Cadence
20–120 flacons/min

Fonctionnement

Tablets/capsules in the hopper are conveyed in an orderly, non-overlapping manner by the electromagnetic vibration feed system to the detection channel inlet. A vision imaging system (linear CCD camera with ARM processor) counts the products as they pass. Based on the preset fill quantity, a combination gate mechanism divides and pre-stores the counted product before delivering it into bottles via a bottle-switching device, which then passes the filled bottle to the next process.

Processus de fonctionnement
1Tablets/capsules in the hopper are conveyed in an orderly, non-overlapping manner by the electromagnetic vibration feed system to the detection channel inlet.
2A vision imaging system (linear CCD camera with ARM processor) counts the products as they pass.
3Based on the preset fill quantity, a combination gate mechanism divides and pre-stores the counted product before delivering it into bottles via a bottle-switching device, which then passes the filled bottle to the next process.

Caractéristiques techniques

Caractéristiques de la variante : SED-8SX4-S

Caractéristiques

Modèle
SED-8SX4-S
Cadence
20–120 flacons/min
Tension
220V AC, 50/60 Hz
Fluides et énergie
Compressed air at 0.5 MPa
Puissance
1.5 kW
Pression d’air
0.5Mpa

Dimensions

Longueur
1900 mm
Largeur
1800 mm
Hauteur
1600 mm
Poids
470 kg

Matériaux

Matériaux en contact
304 acier inoxydable
Matériaux du bâti
304 acier inoxydable

Caractéristiques principales

Vision imaging electronic tablet counter (linear CCD camera)
High-speed ARM processor with embedded HMI software
Electromagnetic vibration principle for smooth, separated product flow
Closed-loop vibration control technology for stable, low-noise operation
High-pressure dust removal function (auto-adjustable interval)
Patented combination gate cutting device (US MAC solenoid valves + Japan SMC cylinders)
Power auto-voltage stabilization system
Compressed air pressure monitoring and auto-shutdown
Inlet/outlet photoelectric detection for bottle jam and absence detection
Dust collection device and product recovery tray
304 stainless steel body, fully sealed, GMP-compliant
Counting accuracy: 99.99%
Detection precision: 0.12 mm per imaging point
High sensitivity and rapid response for counting accuracy
Excellent dust resistance with built-in high-pressure purging
Zero counting error
Automatic voltage stabilization for reliable operation
Full GMP compliance
Suitable for tablets up to Ø22 mm and capsules from #00 to #5

Applications

Comprimés
Gélules

Secteurs

Pharmaceutique

Marques des composants

Industrial camera: Hikvision custom (using Toshiba image sensor)
Light source: OSRAM LED custom-made
Vision counting control board: self-developed
Industrial HMI PC: VFACE
Inverter: Schneider (France) ATV12H075M2
Gate solenoid valve: MAC (USA) 44C-ABA-GDFA
Gate cylinder: SMC (Japan) CJ2KB16-40Z
Platform cylinder: SMC (Japan) CXSM15-35 / CXSM15-45
Solenoid valve: SMC (Japan) SY5120-5L-01
Digital pressure switch: SMC (Japan) ISE30A
Air filter regulator: SMC (Japan) AW30-03BG-B
Photoelectric switch: SICK (Germany) GTB6-N1212
Vibration controller: CUH SDVC34-MR
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

GMP

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→