SED-800YXSPY-H High Performance Liquid Chromatograph (HPLC) comprising: quaternary low-pressure pump with online degasser (4-channel, 480 µL/channel), photodiode array (PDA) detector (190–700 nm), 100-position autosample

Choisir une variante (4)
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

The sample is injected by the autosampler and the quaternary low-pressure pump drives the mobile phase through the C18 column under high pressure. Sample components are separated by differential interaction with the stationary phase and eluted at different retention times; a UV-Vis PDA detector measures absorbance across 190–800 nm, and the chromatography workstation collects data for quantitative and qualitative analysis.

Processus de fonctionnement
1The sample is injected by the autosampler and the quaternary low-pressure pump drives the mobile phase through the C18 column under high pressure.
2Sample components are separated by differential interaction with the stationary phase and eluted at different retention times; a UV-Vis PDA detector measures absorbance across 190–800 nm, and the chromatography workstation collects data for quantitative and qualitative analysis.

Caractéristiques techniques

Caractéristiques de la variante : SED-800YXSPY-H quaternary low-pressure pump with online degasser

Caractéristiques

Modèle
SED-800YXSPY-H
Tension
220V 50Hz 1Φ

Caractéristiques principales

Quaternary low-pressure pump, max pressure 6000 psi (40 MPa)
Flow rate range: 0.001–10.000 mL/min (increment 0.001 mL/min)
Flow rate precision: ≤0.06% RSD (ASTM)
Flow rate accuracy: ±0.2%
Pressure pulsation: ≤1%
Gradient accuracy: ±0.5%; gradient repeatability: ≤0.1%
Online degasser (4-channel, 480 µL/channel); plunger online wash (high/medium/low speed)
PDA detector, wavelength range 190–800 nm; deuterium + tungsten dual lamp
Spectral bandwidth: 8 nm; wavelength accuracy: ±1 nm; noise: ±0.35×10⁻⁵ AU (ASTM)
Drift: 1×10⁻⁴ AU/hr; linear range >2.5 AU (ASTM); maximum sampling rate: 100 Hz
Flow cell: 10 mm path length, 1200 PSI pressure rating
Minimum detection concentration: 4×10⁻⁹ g/mL
100-position autosampler; injection modes: full loop / partial / µL pick-up
Sample injection repeatability: full loop RSD≤0.3%; partial RSD≤0.5%; µL pick-up RSD≤1%
Carryover: <0.005%
Column oven temperature range: RT+5°C to 70°C, accuracy ±1.0°C, stability ±0.1°C; refrigeration function included
Chromatography workstation compliant with FDA 21 CFR Part 11 / GMP / GLP
User permissions management; automated peak width and threshold algorithm
PDA detector wide wavelength range (190–700 nm) for multi-wavelength analysis
Chromatography workstation compliant with FDA 21 CFR Part 11 / GMP / GLP regulations
Automatic peak width and threshold algorithm with self-adaptive data acquisition
Standard 100-position autosampler; compatible with 96-well / 384-well plates

Applications

Pharmaceutical analysis
Food safety testing
Chemical analysis
HPLC quantitative and qualitative analysis

Secteurs

Fabrication pharmaceutique
Laboratory / R&D
Food inspection
Chemical industry
QC quality control
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→