SED-7800GPY-D Fourier Transform Infrared (FTIR) Spectrometer is a domestically developed instrument with proprietary IP, offering stable performance, simple operation, long service life and low maintenance. Used in pharm

Chinese pharmacopeia audit-trail compliance3Q (IQ/OQ/PQ) qualification supported
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

An infrared light source illuminates a Michelson-type interferometer; the moving mirror modulates the beam to produce an interferogram, which is recorded by a high-sensitivity imported detector after passing through the sample. A 24-bit A/D converter digitizes the signal; embedded software computes the FFT to produce a frequency-domain absorbance/transmittance spectrum across 7800-350 cm-1 at sub-1.0 cm-1 resolution. The integrally cast optical bench, sealed interferometer and humidity sensor minimize drift and protect the multilayer-coated KBr beamsplitter.

Processus de fonctionnement
1An infrared light source illuminates a Michelson-type interferometer; the moving mirror modulates the beam to produce an interferogram, which is recorded by a high-sensitivity imported detector after passing through the sample.
2A 24-bit A/D converter digitizes the signal; embedded software computes the FFT to produce a frequency-domain absorbance/transmittance spectrum across 7800-350 cm-1 at sub-1.0 cm-1 resolution.
3The integrally cast optical bench, sealed interferometer and humidity sensor minimize drift and protect the multilayer-coated KBr beamsplitter.

Caractéristiques techniques

Caractéristiques de la variante : SED-7800GPY-D

Caractéristiques

Modèle
SED-7800GPY-D
Tension
220V 50Hz 1Φ

Dimensions

Longueur
450 mm
Largeur
350 mm
Hauteur
210 mm

Matériaux

Matériaux en contact
Multilayer-coated potassium bromide (KBr) beamsplitter; sealed interferometer chamber
Matériaux du bâti
Integrally molded one-piece optical bench casting; metal enclosure

Caractéristiques principales

Spectral range 7800-350 cm-1
Resolution better than 1.0 cm-1
Signal-to-noise 20,000:1 (P-P @ 4 cm-1)
Integrally molded optical bench (no field re-alignment)
Sealed interferometer with humidity quick-recognition and color-change desiccant indicator
Desiccant replaceable without opening the cover
24-bit A/D converter for high-fidelity digitization
Imported high-sensitivity detector
Multilayer-coated KBr beamsplitter with moisture-proof coating
Long-life high-intensity air-cooled IR source
Microcomputer-controlled variable scan speed with auto spectrum comparison
Three-level user-permission audit trail (Chinese pharmacopeia compliant)
3Q (IQ/OQ/PQ) qualification service
Domestic IP — no import licensing or supply-chain risk vs Bruker/Thermo equivalents
Sealed optical design eliminates the most common FTIR failure (humidity damage to beamsplitter)
Audit-trail and 3Q service make this pharma-QC ready out of the box
Large sample chamber accepts ATR / gas / liquid / polarization accessories

Applications

Pharmaceutical raw-material identification and finished-product QC
Chemical and polymer characterization
Petroleum and energy analysis
Environmental and food analysis
Materials science research
Public security and forensic analysis
Defense and semiconductor / optics research

Secteurs

Pharmaceutique
Chemical
Petroleum
Environmental
Food
Matériaux
Public security / forensics
Defense
Semiconductor
Optics

Marques des composants

IR detector (high sensitivity)
Imported
KBr beamsplitter (multilayer-coated, moisture-proof)
Imported
IR light source (long-life, air-cooled)
Imported
Data interface
USB 2.0 high-speed
Operating system
Windows 7 64-bit
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

Chinese pharmacopeia audit-trail compliance
3Q (IQ/OQ/PQ) qualification supported

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→