Showroom à Ontario, Californie · Assistance à confirmer pour votre destination
Accueil / Équipements / Laveuse de flacons de laboratoire / Laboratory Glassware Washer-Disinfector
SED-650SXP-A
Sur devis
SED-650SXP-A
SED · SED-650SXP-A · En vedette

SED-650SXP-A — Laboratory Glassware Washer-Disinfector

La description complète de ce modèle est encore en cours de traduction. Consultez les détails en anglais ou demandez des informations à notre équipe. English

SED-650SXP-A laboratory glassware washer-disinfector. Vertical design, twin double-pane vacuum-glass doors with motorized lift (visible area 80×65 cm) and rivet-free 304L stainless outer / 316L mirror-polished inner cham

ISO9001ISO14001CE
Délai de livraison
Sur devis
Cadence
Contactez-nous

Fonctionnement

Glassware loaded onto basket racks with side water-feed manifold; chamber double doors close and lock. PLC selects the user-chosen wash program; the European high-temperature recirc pump (1000 L/min) drives water through a rotating spray-arm system (with speed/pressure feedback). Auto flowmeter + level sensor meter detergent and rinse water; the heater raises wash water up to 93°C with AO-value monitoring for thermal disinfection (organic residue <0.1 mg/L, metal ions <0.02 mg/L). After wash and rinse cycles complete, an injection-style hot-air system blows H13-HEPA-filtered heated air directly through the outlet manifold into each glassware piece for drying (room temp to 120°C, up to 300 min). Door interlock prevents opening until temperature drops to a configurable safe value.

Processus de fonctionnement
1Glassware loaded onto basket racks with side water-feed manifold; chamber double doors close and lock.
2PLC selects the user-chosen wash program; the European high-temperature recirc pump (1000 L/min) drives water through a rotating spray-arm system (with speed/pressure feedback).
3Auto flowmeter + level sensor meter detergent and rinse water; the heater raises wash water up to 93°C with AO-value monitoring for thermal disinfection (organic residue <0.1 mg/L, metal ions <0.02 mg/L).
4After wash and rinse cycles complete, an injection-style hot-air system blows H13-HEPA-filtered heated air directly through the outlet manifold into each glassware piece for drying (room temp to 120°C, up to 300 min).
5Door interlock prevents opening until temperature drops to a configurable safe value.

Caractéristiques techniques

Caractéristiques de la variante : SED-650SXP-A

Caractéristiques

Modèle
SED-650SXP-A
Tension
380V 50Hz 3Φ
Fluides et énergie
380V/50Hz, 3-phase power; tap water and purified water supply; drain outlet. Installation environment: 5–32°C, relative humidity ≤85%.
Puissance
17 kW

Matériaux

Matériaux en contact
316L stainless steel (mirror-polished); H13 HEPA filter media
Matériaux du bâti
304L stainless steel outer; 316L stainless steel chamber; rivet-free welded

Caractéristiques principales

Vertical design with motorized double vacuum-glass doors and 80×65 cm viewing area
316L mirror-polished cleaning chamber, 304L stainless outer with rivet-free construction
PLC + 7" color touchscreen control with 11 preset + 100 user programs
Cloud-connected software with remote logging/control upgrade path
European imported high-temperature recirc pump (1000 L/min, 93°C duty)
Pipe pressure and spray-arm rotation speed sensors with live readout
AO-value monitoring for thermal disinfection (organic residue <0.1 mg/L, metal ions <0.02 mg/L)
Injection-style hot-air drying through outlet manifold with H13 (99.99%) HEPA filter (RT–120°C, 0–300 min)
Auto flowmeter + level sensor double-control inlet metering
Comprehensive interlocks: dry-fire, pump dry-run, overflow, low-detergent, door-not-closed
Power-loss memory: resumes program after outage
Automated lab glassware cleaning, disinfection and drying in one cabinet
AO-value documentation gives auditable proof of disinfection
Verified residue spec: organics <0.1 mg/L, metal ions <0.02 mg/L
European pump and high-spec sensors — imported quality
ISO9001, ISO14001, CE certifications and provincial-level electrical safety test reports available

Applications

Cleaning of laboratory glassware: volumetric flasks, conical flasks, round-bottom flasks, test tubes
Cleaning of GC/HPLC autosampler vials, headspace vials, mobile-phase bottles
Cleaning of separating funnels, syringes, evaporating dishes, crucibles, weighing bottles
Cleaning of microscope slides, coverslips, pipette tips, large reagent bottles
Thermal disinfection of glassware with AO-value documentation

Secteurs

Pharmaceutical R&D / QC laboratories
Clinical laboratories
Chemical analysis / academic labs
Hospital laboratories

Marques des composants

High-temperature circulation pump (1000 L/min)
European OEM imported
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

ISO9001
ISO14001
CE

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→