SED-500DTP-H thousandth (1 mg) analytical electronic balance. Multi-function precision balance using electromagnetic force balance sensor for fast and accurate weighing. Max capacity 500 g, readability 1 mg (0.001 g). In

CECertificate of Conformity
Délai de livraison
Sur devis
Cadence
0.5 kg

Fonctionnement

Electromagnetic force balance: the weighing pan is connected to a current-carrying coil placed in a permanent magnetic field. When mass is placed on the pan, gravity pulls it downward; an electromagnetic force is generated in the coil to oppose it. Sensor output is rectified and amplified, adjusting coil current until mechanical equilibrium is restored. The coil current is proportional to the weight, and the signal is processed to display mass. Uses German STL Institute sensor software technology for multi-point calibration and stability.

Processus de fonctionnement
1Electromagnetic force balance: the weighing pan is connected to a current-carrying coil placed in a permanent magnetic field.
2When mass is placed on the pan, gravity pulls it downward; an electromagnetic force is generated in the coil to oppose it.
3Sensor output is rectified and amplified, adjusting coil current until mechanical equilibrium is restored.
4The coil current is proportional to the weight, and the signal is processed to display mass.
5Uses German STL Institute sensor software technology for multi-point calibration and stability.

Caractéristiques techniques

Caractéristiques de la variante : SED-500DTP-H

Caractéristiques

Modèle
SED-500DTP-H
Cadence
0.5 kg
Tension
AC mains via power cord (typ. 220V/50Hz)
Fluides et énergie
AC mains via supplied power cord (typically 220V/50Hz; 110V input noted in some source versions).
Détails de conformité
Operating temperature 15-35 degC (recommended 17.5-22.5 degC for optimal accuracy). Recommend placement on marble platform, away from doors/windows, vibration sources, direct sunlight, heaters, and magnetic fields. Do not use in explosive atmospheres or prolonged high-humidity/dust environments. After moving from cold to warm environment, leave unplugged for 2 hours before use.

Dimensions

Longueur
300 mm
Largeur
200 mm
Hauteur
295 mm
Poids
5 kg
Emprise au sol
Machine 300x200x295 mm (LxWxH); package 425x320x415 mm; net weight 5.0 kg, gross weight 6.0 kg.

Matériaux

Matériaux en contact
Stainless-steel weighing pan (diameter Phi80 mm; Phi90 mm optional)
Matériaux du bâti
Plastic / metal housing with anti-static-coated glass draft shield (4 sides) and side & top sliding doors

Caractéristiques principales

Max capacity 500 g; readability 0.001 g (1 mg)
Repeatability +/-0.002 g; linearity +/-0.003 g
Stable time <=3 seconds
Pan diameter Phi80 mm (Phi90 mm optional)
Electromagnetic force balance sensor with German STL Institute software
Linear 4-point calibration; external calibration weight included
Full-range tare, clear, accumulate, overload/underload display, fault alarm
Counting function
Multi-unit conversion: gram, carat, ounce
Blue backlit large LCD display (120x55 mm)
Anti-static coated glass draft shield (4 sides, sliding top and side doors)
RS232 standard interface (RS485 and USB available as custom options)
Adjustable integral/stability/sensitivity
1 mg readability at consumer-friendly price point
German STL Institute sensor software technology for stable performance and multi-point calibration
Anti-static draft shield reduces measurement drift in dry environments
RS232 interface for printer / computer integration

Applications

Laboratory analytical weighing of small samples (<=500 g)
Pharmaceutical / R&D / QC weighing
Counting of small uniform parts
Multi-unit weighing (g, carat, oz)

Secteurs

Pharmaceutical R&D and QC labs
Chemical / materials laboratories
Education and research institutions
Industrial metrology

Marques des composants

Electromagnetic force balance sensor software technology -- German STL Institute
SED
Échangez avec SED Sales Team
Spécialistes des équipements · contact sur WhatsApp
Consultez les horaires et la disponibilité de l’équipe

Conformité

CE
Certificate of Conformity

Nettoyage et entretien

Keep workspace clean and dry. Before cleaning, unplug the power supply. Do not use corrosive cleaning agents. Use a lint-free soft cloth dampened with water and neutral detergent. Avoid water entering the balance. Wipe dry. Avoid static-electricity buildup in dry environments.

Documentation

Fiche technique (PDF)
Aperçu de l’équipement, caractéristiques et dimensions · Document d’origine (anglais)
Demander au service commercial
Manuel opérateur
Installation, fonctionnement et dépannage · Document d’origine (anglais)
Demander au service commercial
Fiche comparative (Standard et Économique)
Comparaison des configurations · Document d’origine (anglais)
Demander au service commercial
Protocoles IQ / OQ / PQ
Documentation de validation pour la conformité GMP · Document d’origine (anglais)
Demander au service commercial
Protocoles FAT / SAT
Essais de réception en usine et sur site · Document d’origine (anglais)
Demander au service commercial
Plans CAD (STEP / IGES / DWG)
Plans d’ingénierie pour l’implantation · Document d’origine (anglais)
Demander au service commercial
Certificats d’étalonnage
Niveau sonore, résistance de terre, rigidité diélectrique et rugosité · Document d’origine (anglais)
Demander au service commercial
DQ (qualification de la conception)
Protocole complet de qualification de la conception · Document d’origine (anglais)
Demander au service commercial
Certificats matières
Composition de l’acier inoxydable 316L · Document d’origine (anglais)
Demander au service commercial
SED
WhatsApp · Ventes SED
Contact commercial · WhatsApp
→